electronic XLR jack JINJIA XLR-14W suitable for temperature range minus 30 to plus 80 degrees Celsius

Price Negotiable
Price: Negotiable
MOQ: Negotiable
Delivery Time: Negotiable
Product Description

XLR Jack Specification

This specification applies to XLR jacks used in electronic products. It details the product's operational and storage conditions, electrical and mechanical performance, durability, solderability, and environmental resistance.

Product Attributes

  • Brand: Shenzhen Jinjiarun Electronic Technology Co., Ltd
  • Origin: China
  • Document Number: JJR-WI-47
  • Issue Date: 2008-09-10
  • Version: A1

Technical Specifications

ItemPropertyTest ConditionPerformance
2. Rated /
Practical temperature range-30 to +80
Humidity range85% RH.MAX.
Preservation temperature range-10 to +40
Humidity range (Preservation)85% RH.MAX.Surrounding air without acid, alkaline or other corrosive gases. Storage period not exceeding 180 days.
Rated voltage and current (MAX.)50V AC , 6A
AppearanceNo scratches, soil, rust or discoloration on the surface.
3. Construction /
Outline And DimensionShould match the attachment drawing.
Part And MaterialShould be consistent with the material list specifications.
4. Electrical efficiency /
Withstand VoltageWithstand AC 1500V (50/60Hz RMS) between two non-contact terminals for 1 minuteNo dielectric breakdown shall occur.
Insulation ResistanceApply 500V DC between any contactless terminal and the other terminal, with an insulation gauge and last for 1 minute 5 seconds.10000 M Min.
Contact ResistanceTake a pair of matched terminals and measure the tail end of each terminal (voltage maximum 20mV, current maximum 100mA)30 m MAX.
5. Mechanical Performance
Insertion and withdrawal forcesRate of insertion/withdrawal: 2 mm/sMating of complete connectors without the effect of any latching or retaining deviceInsertion: 35 N max. Withdrawal: 2 N min.
Terminal StrengthEvery terminal should be capable of withstand a force of 0.5 kgf for 10 seconds.No looseness, damage, etc., but terminal deformation is acceptable.
6. Durability /
Life testUnder the condition of no load, rotate and then plug in, rotate and then pull out with a matching plug for 1000 times in total, at a frequency of 5 times per minute.No obvious change in appearance, destruction. Contact resistance: less than 50 m.
7. Solderability /
Resistance to soldering heatThe jack terminal should be dipped in solderTemperature of solder: 2603. Dip time: 51 seconds.After the test, the plastic base should not be deformed and the terminals should not fall off the plastic base.
SolderabilityTemperature of solder: 2453C. Time of dip: 30.5 seconds.Coating of solder area should be more than 95%
8. Environment test /
Cold testPlace the housing for 96 hours at a low temperature of -30 3 C. Then, place it under standard atmospheric conditions for 1 hour and test.No obvious change in appearance. Contact resistance: 50 m max. Insulation resistance: 500 M min. Withstand voltage: AC 1000V.
Heat testThe housing should be stored at a temperature of 802 for 96 hours. Then it should be subjected to standard atmospheric conditions for 1 hour and test.
Humidity testThe housing should be stored at a temperature of 403 with relative humidity of 90% ~ 95% for 96 h. Then it should be subjected to standard atmospheric conditions for 1 hour and test.No obvious change in appearance. Contact resistance: 50m max. Insulation resistance: 500 M min. Withstand voltage: AC 1000V.
Temperature CyclingPlace the Jack under the conditions shown below and then place it in the stand at room temperature for 30 minutes.
Salt spray testTemperature: 35 2 Solution: 5 1% Spray time: 24 hours. Wash and dry it at room temperature after the experiment.No obvious rust in the appearance.
9. Test condition /
Unless otherwise specified, the test and measurement temperature is between 15 C and 35 C, the relative humidity is between 25% and 85%, and the atmospheric pressure is between 86 kPa and 106 kPa. However, when any doubts arise on the judgment value under the above condition, the test and measurement are carried out at 201 C, the relative humidity is 63% to 67%, and the air pressure is performed at 86 kPa to 106 kPa.
10. Amendment /
When it is necessary to amend the specifications, it should be negotiated and agreed by the manufacturer and the customer before proceeding.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Hefei Purple Horn E-Commerce Co., Ltd.
Location Room 1306B, Building A, Xindi Center, Qimen Road, Hefei City, Anhui Province
Contact Person Sellina