Product Description

XLR Jack Specification

This specification applies to XLR jacks used in electronic products. It details the product's rated values, construction, electrical characteristics, mechanical performance, durability, solderability, environmental resistance, and testing conditions.

Product Attributes

  • Brand: Shenzhen jinjiarun Electronic Technology Co., Ltd
  • Origin: China
  • Model Type: XLR JACK

Technical Specifications

ItemPropertyTest ConditionPerformance
2. Rated /
Practical temperature range-30to +80
Humidity range85% RH.MAX.
Preservation temperature range-10to +40
Humidity range (Preservation)85% RH.MAX.
Storage ConditionAmbient air without acid, alkaline, or corrosive gases. Storage period not exceeding 180 days.
Rated voltage and current (MAX.)50V AC , 6A
AppearanceNo scratches, soil, rust, or discoloration on the surface.
3. Construction /
Outline And DimensionShould match the attachment drawing.
Part And MaterialShould be consistent with the material list specifications.
4. Electrical efficiency /
Withstand VoltageWithstand AC 1500V (50/60Hz RMS) between two non-contact terminals for 1 minute. No dielectric breakdown shall occur.Between two non-contact terminalsNo dielectric breakdown
Insulation ResistanceApply 500V DC between any contactless terminal and the other terminal, with an insulation gauge and last for 1 minute 5 seconds.Between contactless terminals10000 M Min.
Contact ResistanceTake a pair of matched terminals and measure the tail end of each terminal (voltage maximum 20mV, current maximum 100mA).Matched terminals, tail end measurement30 m MAX.
5. Mechanical Performance /
Insertion and withdrawal forcesRate of insertion/withdrawal: 2 mm/s. Mating of complete connectors without the effect of any latching or retaining device.Insertion: 35 N max. Withdrawal: 2 N min.
Terminal StrengthEvery terminal should be capable of withstand a force of 0.5 kgf for 10 seconds. There is no looseness, damage, etc., but terminal deformation is acceptable.No looseness, damage. Deformation acceptable.
6. Durability /
Life testUnder no load conditions, rotate and then plug in, rotate and then pull out with a matching plug for 1000 times in total, at a frequency of 5 times per minute.Matching plug, 1000 cyclesAppearance: No obvious change. Contact resistance:
7. Solderability /
Resistance to soldering heatThe jack terminal should be dipped in solder: Temperature 2603, Dip time 51 seconds. After the test, the plastic base should not be deformed and the terminals should not fall off the plastic base.Solder dipPlastic base: No deformation. Terminals: No detachment.
SolderabilityTemperature of solder: 2453C. Time of dip: 30.5 seconds. Coating of solder area should be more than 95%.Solder dipSolder area coverage: > 95%.
8. Environment test /
Cold testPlace the housing for 96 hours at -30 3 C. Then, place under standard atmospheric conditions for 1 hour and test.-30 3 C for 96h, then 1h standard conditionsAppearance: No obvious change. Contact resistance: 50 m. Insulation resistance: 500 M. Withstand voltage: AC 1000V.
Heat testThe housing should be stored at 802 for 96 hours. Then, subject to standard atmospheric conditions for 1 hour and test.802 for 96h, then 1h standard conditions
Humidity testStore at 403 with 90% ~ 95% RH for 96 h. Then, subject to standard atmospheric conditions for 1 hour and test.403, 90%~95% RH for 96h, then 1h standard conditionsAppearance: No obvious change. Contact resistance: 50 m. Insulation resistance: 500 M. Withstand voltage: AC 1000V.
Temperature CyclingPlace the Jack under specified conditions and then place in stand at room temperature for 30 minutes.Specified conditions
Salt spray testTemperature: 35 2. Solution: 5 1%. Spray time: 24 hours. Wash and dry at room temperature after the experiment.35 2, 5 1% salt solution, 24hAppearance: No obvious rust.
9. Test condition /
Standard conditionsTest and measurement temperature: 15C to 35C, relative humidity: 25% to 85%, atmospheric pressure: 86 kPa to 106 kPa.
Doubtful conditionsTest and measurement at 201C, relative humidity 63% to 67%, and air pressure 86 kPa to 106 kPa.
10. Amendment /
ProcedureAmendments require negotiation and agreement between the manufacturer and the customer.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Hefei Purple Horn E-Commerce Co., Ltd.
Location Room 1306B, Building A, Xindi Center, Qimen Road, Hefei City, Anhui Province
Contact Person Sellina

Request A Quote

Please check your email address.
Your message must be at least 20 characters.