electrical component SHOU HAN AF SS-JB17.6 rated for DC 30V 1.5A operation within temperature range

Price Negotiable
Price: Negotiable
MOQ: Negotiable
Delivery Time: Negotiable
Product Description

Product Overview

This document outlines the specifications for the SHENZHEN SHOUHAN TECHNOLOGY CO.,LTD SS-JB17.6 product. It details the product's technical performance, including electrical, mechanical, and durability characteristics, designed for use within a specified temperature range.

Product Attributes

  • Brand: (SHENZHEN SHOUHAN TECHNOLOGY CO.,LTD)
  • Origin: (Shenzhen)
  • Part Number: SS-JB17.6
  • Customer Approval Signatures: (Li Chunfeng), (Zhong Huahua), (Luo Xiaojin)
  • Drawn By: (Li Chunfeng)
  • Checked By: (Luo Xiaojin)
  • Approved By: (Zhong Huahua)

Technical Specifications

ItemProjectTest ConditionsPerformanceSpecification
RATINGPRACTICAL TEMPERATURE RANGE-25~85CWithin -25C to +85C temperature
RATINGDC 30V 1.5A
STANDARD ATMOSPHEIC CONDITIONSUNLESS OTHERWISE SPECIFIED THE STANDARD RANGE OF ATMOSPHERIC CONDITIONS FOR MAKING MEASUREMENTS AND TESTS ARE AS FOLLOWS: (1) BETWEEN BODY AND CONDUCTOR: 5C TO 35 (2) BETWEEN CONDUCTORS NOT TO BE CONTACT45% TO 85% (3) PRESSURE86Kpa TO 106Kpa
(1) Temperature: 5~35
(2) Humidity: 45%~85%
(3) Pressure: 86 Kpa~106Kpa
MECHANICALCONNECTION FORCEMEASUREMENT SHALL BE MADE AFTER CONNECTING AND DISCONNECTING USING STANDARD PLUG GAUGE 3 TIMES.35N
DISCONNECTION FORCEMEASUREMENT SHALL BE MADE AFTER CONNECTING AND DISCONNECTING USING STANDARD PLUG GAUGE 3 TIMES.10N MIN
TERMINAL STRENGTHA STATIC LOAD OF 0.1N/m(1kgf/cm)SHALL BE APPLIED TO THE TIP OF THE TERMINAL FOR 1 MIN IN ANY DIRECTION. THERE SHALL BE NO DAMAGE TO THE TERMINAL SUCH AS CRACKS, LOOSENESS OR PLAY ELECTRICAL ,AND MECHANICAL CHARACTERISTICS SHALL BE SATISFIED
ELECTRICALCONTACT RESISTANCEMEASURED AT SMALL CURRENT 100m A OR LESS 1000Hz30m MAX
INSULATION RESISTANCEAPPLY A VOLTAGE OF 100V DC FOR 1 MIN TO FOLLOWING PORTIONS AFTER WHICH MEASUREMENT SHALL BE MADE: (1) BETWEEN BODY AND CONDUCTOR (2) BETWEEN CONDUCTORS NOT TO BE CONTACT (3) BETWEEN CONDUCTORS NOT TO BE WHEN PLUG IS INSERTED1000M MIN
DIELECTRIC STRENGTHAC 500V ims(50~60Hz)FOR 1 MIN TRIP CURRENT:0.5mA (1) BETWEEN BODYAND CONDUCTOR (2) BETWEEN CONDUCTORS NOT TO BE CONTACL (3) BETWEEN CONDUCTORS NOT TO BE WHEN PLUG IS INSERTED WITHOUT DAMAGE TO PARTS ARCING OR BREAKDOWN ETC
DURABILITYSOLDERABILITY TEST(1) THE TOP OF THE TERMINALS SHALL BE DIPPED 1mm IN THE SOLDER BATH OF 2305 FOR 30.5 SECONDS (2) THE AREA OF SOLDERING SHOULD BE OVER 75%SOLDER WETTING TIME SHALL BE 3 SEC OR LESS
RESISTANCE TO SOLDERING HEAT TEST (REFLOW SOLDERING CONDITIONS)PREHEAT:TEMPERATURE ON THE COPPER FOIL SURFACE SHOULD REACH 180 .120 S AFTER THE P.C.B ENTERED INTO THE SOLDERING EQUIPMENT. TALLEST TEMPERATURE:TEMPERATURE ON THE COPPER FOIL SURFACE SHOULD REACH THE PEAK IN 5 TEMPERATURE OF 2305 WITH SECONDS. WITHOUT DEFOR MATION OF CASE OR EXCESSIVE LOOSENESS OF TEMINALS ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED
RESISTANCE TO SOLDERING HEAT TEST (SOLDERING IRON METHOD)BIT TEMPERATURE 3305 APPLICATION TIME OF SOLDERING IRON30.5 SEC HOWEVER EXCESSIVE PRESSURE SHALL NOT BE APPLIED TO THE TERMINAL WITHOUT DEFORMATION OF CASE OR EXCESSIVE LOOSENESS OF TEMINALS ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED
HUMIDITY TESTTHE JACK SHALL BE STORED AT A TEMPERATURE OF 402 AND A HUMIDITY OF 90%TO 96% FOR 96 Hr,THEN THE JACK SHALL BE MAINTAINED AT STANDARD ATMOSPHERIC CONDITION FOR 1 Hr FOR OTHER PROCEDURES
HEAT TESTTHE JACK SHALL BE STORED AT A TEMPERATURE OF702 FOR 96 HOURSAND THEN IT SHALL BE SUBJECTED TO THE CONTROLLED RECOVERY MBASURBM THERE SHALL BE NO DAMAGE ON APPEARANCE MECHANICAL AND ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED
COLD TESTTHE JACK SHALL BE STORED AT A TEMPERATURE OF-253 FOR 96 HOURS AND THEN IT SHALL BE SUBJECTED TO THE CONTROLLED RECOVERY CONDITIONS FOR 1 HOUR AFTER WHICH THERE SHALL BE NO DAMAGE ON APPEARANCE MECHANICAL AND ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED
LIFE TESTWITHOUT LOADCONNECTION AND DISCONNECTION SHALL BE MADE WITH THE MATING PLUGS AND JACKS FOR 5000 CYCLES AT A SPEED OF 10 TO 25 CYCLES/MIN
LOAD: AT RATING CONDITION NON-INDUCTIVE LOADCONNECTION AND DISCONNECTION SHALL BE MADE 5000 CYCLES AT A SPEED 10 TO 20 CYCLES / MIN(1) CONTACT RESISTANCE SHALL BE 0.1 (2) DISCONNECTION FORCE SHALL BE 0.8 TO 2.0N (3) MECHANICAL AND ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED
TEMPERATURE CYCLING TESTTHE JACK SHALL BE SUBJECTED TO 5 CYCLES OF THE FOLLOWING CONDITIONS SHOWED IN THE FIGURE,AND THEN SHALL RETURNED ALLOWED TO REMAIN IN ROOM AMBIENT CONDITION FOR 30 MINUTES Temp() 100VAC/MIN(BETWEEN TERMINALS) THERE SHALL BE NO DEFORMATION OR CRACKS IN MOLDED PART. INSERTION EXTRACTION FORCE:3 TO 20N CONTACT RESISTANCE:MAX.30M INSULATION RESISTANCE: MIN.100 M DIELECTRIC WITHSTANDING VOLTAGE:
COLD&HEAT SHOCK TESTTHE JACK SHALL BE SUBJECTED TO5 CYCLES OF THE FOLLOWING CONDITIONS SHOWED IN THE FIGURE,AND THEN SHALL RETURNED AND ALLOWED TO REMAIN IN ROOM AMBIENT CONDITION FOR 30 MINUTES TEMP () 500VAC/MIN(BETWEEN TERMINALS) THERE SHALL BE NO DEFORMATION OR CRACKS IN MOLDED PART. INSERTION EXTRACTION FORCE:3 TO 25N CONTACT RESISTANCE:MAX.30M INSULATION RESISTANCE: MIN.100 M DIELECTRIC WITHSTANDING VOLTAGE:

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Hefei Purple Horn E-Commerce Co., Ltd.
Location Room 1306B, Building A, Xindi Center, Qimen Road, Hefei City, Anhui Province
Contact Person Sellina

Request A Quote

Please check your email address.
Your message must be at least 20 characters.