Product Overview
This specification document details the TYPE-C 6P LTH10.5 connector from Shenzhen Shouhan Technology Co., Ltd. It outlines the product's technical specifications, including electrical, mechanical, and durability performance, designed for reliable operation within a specified temperature and atmospheric range.
Product Attributes
- Brand: (SHENZHEN SHOUHAN TECHNOLOGY CO.,LTD)
- Origin: Shenzhen, China
- Product Name: TYPE-C
- Part Number: TYPE-C 6P LTH10.5
Technical Specifications
| Item | Test Conditions | Performance | |||
|---|---|---|---|---|---|
| RATING () | |||||
| DC 5 V 3A | DC 5 V 3A | ||||
| PRACTICAL TEMPERATURE RANGE () | |||||
| -30~80C | -30~80C | ||||
| STANDARD ATMOSPHERIC CONDITIONS () | |||||
| (1) BETWEEN BODY AND CONDUCTOR | (1) 5~35 | (1) 5C TO 35 | (1) 5~35 | ||
| (2) BETWEEN CONDUCTORS NOT TO BE CONTACT | (2) 45%~85% | (2) 45% TO 85% | (2) 45%~85% | ||
| (3) PRESSURE | (3) 86Kpa TO 106Kpa | (3) 86Kpa TO 106Kpa | (3) 86Kpa~106Kpa | ||
| MECHANICAL () | |||||
| 1 | CONNECTION FORCE | MEASUREMENT SHALL BE MADE AFTER CONNECTING AND DISCONNECTING USING STANDARD PLUG GAUGE 3 TIMES | PLUG GAUGE 3 | 0.52.0Kgf | 0.52.0Kgf |
| 2 | DISCONNECTION FORCE | MEASUREMENT SHALL BE MADE AFTER CONNECTING AND DISCONNECTING USING STANDARD PLUG GAUGE 3 TIMES | PLUG GAUGE 3 | 0.82.0Kgf | 0.82.0Kgf |
| 3 | TERMINAL STRENGTH | A STATIC LOAD OF 0.1N/m(1kgf/cm)SHALL BE APPLIED TO THE TIP OF THE TERMINAL FOR 1 MIN IN ANY DIRECTION | 1 0.1N/m(1kgf/cm). | THERE SHALL BE NO DAMAGE TO THE TERMINAL SUCH AS CRACKS, LOOSENESS OR PLAY ELECTRICAL ,AND MECHANICAL CHARACTERISTICS SHALL BE SATISFIED | |
| ELECTRICAL () | |||||
| 3.1 | CONTACT RESISTANCE | MEASURED AT SMALL CURRENT 100m A OR LESS 1000Hz | 100 m A | 40m MAX | 40m MAX |
| 3.2 | INSULATION RESISTANCE | APPLY A VOLTAGE OF 100V DC FOR 1 MIN TO FOLLOWING PORTIONS AFTER WHICH MEASUREMENT SHALL BE MADE: (1) BETWEEN BODY AND CONDUCTOR (2) BETWEEN CONDUCTORS NOT TO BE CONTACT (3) BETWEEN CONDUCTORS NOT TO BE WHEN PLUG IS INSERTED | 100V DC 1 1 2 3 | 100M MIN | 100M MIN |
| 3.3 | DIELECTRIC STRENGTH | AC 100V ims(50~60Hz)FOR 1 MIN TRIP CURRENT:0.5mA (1) BETWEEN BODY AND CONDUCTOR (2) BETWEEN CONDUCTORS NOT TO BE CONTACL (3) BETWEEN CONDUCTORS NOT TO BE WHEN PLUG IS INSERTED | AC 100V 50Hz/min 1 0.5mA, : (1) (2) (3) | WITHOUT DAMAGE TO PARTS ARCING OR BREAKDOWN ETC | |
| DURABILITY () | |||||
| 4.1 | SOLDERABILITY TEST | THE TOP OF THE TERMINALS SHALL BE DIPPED 1mm IN THE SOLDER BATH OF 2505 FOR 50.5 SECONDS | 1mm ,2505,5 0.5 | 1SOLDER WETTING TIME SHALL BE 3 SEC OR LESS 2THE AREA OF SOLDERING SHOULD BE OVER 75% | 13 275% |
| 4.2 | RESISTANCE TO SOLDERING HEAT TEST | REFLOW SOLDERING CONDITIONS: PREHEAT:TEMPERATURE ON THE COPPER FOIL SURFACE SHOULD REACH 180 .120 S AFTER THE P.C.B ENTERED INTO THE SOLDERING EQUIPMENT. TALLEST TEMPERATURE:TEMPERATURE ON THE COPPER FOIL SURFACE SHOULD REACH THE PEAK TEMPERATURE OF 2605 WITH IN 20 SECONDS. | :180,120s :260520 | WITHOUT DEFOR MATION OF CASE OR EXCESSIVE LOOSENESS OF TEMINALS ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED | |
| SOLDERING IRON METHOD: BIT TEMPERATURE 3305 APPLICATION TIME OF SOLDERING IRON30.5 SEC HOWEVER EXCESSIVE PRESSURE SHALL NOT BE APPLIED TO THE TERMINAL | 3305 30.5 | WITHOUT DEFOR MATION OF CASE OR EXCESSIVE LOOSENESS OF TEMINALS ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED | |||
| 4.3 | HUMIDITY TEST | THE JACK SHALL BE STORED AT A TEMPERATURE OF 402 AND A HUMIDITY OF 90%TO 96% FOR 96 Hr,THEN THE JACK SHALL BE MAINTAINED AT STANDARD ATMOSPHERIC CONDITION FOR 1 Hr FOR OTHER PROCEDURES | 402 90~96% Hr 96 1 | THERE SHALL BE NO DAMAGE ON APPEARANCE MECHANICAL AND ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED | |
| 4.4 | HEAT TEST | THE JACK SHALL BE STORED AT A TEMPERATURE OF702 FOR 96 HOURSAND THEN IT SHALL BE SUBJECTED TO THE CONTROLLED RECOVERY MBASURBM | 70296 1 | THERE SHALL BE NO DAMAGE ON APPEARANCE MECHANICAL AND ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED | |
| 4.5 | COLD TEST | THE JACK SHALL BE STORED AT A TEMPERATURE OF-253 FOR 96 HOURS AND THEN IT SHALL BE SUBJECTED TO THE CONTROLLED RECOVERY CONDITIONS FOR 1 HOUR AFTER WHICH | -25396 1 | THERE SHALL BE NO DAMAGE ON APPEARANCE MECHANICAL AND ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED | |
| 4.6 | LIFE TEST | WITHOUT LOAD CONNECTION AND DISCONNECTION SHALL BE MADE WITH THE MATING PLUGS AND JACKS FOR 5000 CYCLES AT A SPEED OF 10 TO 25 CYCLES/MIN | Plug()1 10-255000 | (1) CONTACT RESISTANCE SHALL BE 0.1 (2) DISCONNECTION FORCE SHALL BE 0.8 TO 2.0N (3) MECHANICAL AND ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED | (1) 0.1 (2) 0.8~2.0N (3) :, |
| LOAD AT RATING CONDITION NON-INDUCTIVE LOAD CONNECTION AND DISCONNECTION SHALL BE MADE 5000 CYCLES AT A SPEED 10 TO 20 CYCLES / MIN | ()1 10-20 5000 | ||||
| 4.7 | TEMPERATURE CYCLING TEST | THE JACK SHALL BE SUB JECTED TO 5 CYCLES OF THE FOLLOWING CONDITIONS SHOWED IN THE FIGURE,AND THEN SHALL RETURNED ALLOWED TO REMAIN IN ROOM AMBIENT CONDITION FOR 30 MINUTES | 5 30 | THERE SHALL BE NO DEFORMATION OR CRACKS IN MOLDED PART. INSERTION EXTRACTION FORCE:3 TO 20N CONTACT RESISTANCE:MAX.30M INSULATION RESISTANCE: MIN.100 M DIELECTRIC WITHSTANDING VOLTAGE: 100VAC/MIN(BETWEEN TERMINALS) | 3N 20N 30m 100 M 100VAC |
| 4.8 | COLD&HEAT SHOCK TEST | THE JACK SHALL BE SUBJECTED TO5 CYCLES OF THE FOLLOWING CONDITIONS SHOWED IN THE FIGURE,AND THEN SHALL RETURNED AND ALLOWED TO REMAIN IN ROOM AMBIENT CONDITION FOR 30 MINUTES | 5 30 | THERE SHALL BE NO DEFORMATION OR CRACKS IN MOLDED PART. INSERTION EXTRACTION FORCE:3 TO 25N CONTACT RESISTANCE:MAX.30M INSULATION RESISTANCE: MIN.100 M DIELECTRIC WITHSTANDING VOLTAGE: 500VAC/MIN(BETWEEN TERMINALS) | 3N 25N 30m 100 M 500VAC |