Function: DC Power Jack Connector
Usage: For power input in electronic devices.
Application Scenarios: Suitable for general electronic equipment requiring a DC power connection.
Product Attributes
BrandHanxia Electronic
Model/Part No.HX DC005
OriginShenzhen, China
Customer ApprovalHuang Bin, Luo Xiaochun
Drawn ByZhang Wei
Checked ByZhang Wei
Approved ByLuo Xiaochun
Technical Specifications
| Specification | Value | Unit | Test Condition |
|---|---|---|---|
| Rated Voltage | 30 | V DC | - |
| Rated Current | 1.0 | A | - |
| Contact Resistance | 50 | m MAX | Measured at 1KHz small current |
| Insulation Resistance | 100 | M Min | Applied DC500V for 1 minute |
| Withstand Voltage | 500 | V AC | Applied AC500V (50/60Hz) for 1 minute |
| Mate Force | 3-30 | N | Measured with ergometer |
| Unmate Force | 3-30 | N | Measured with ergometer |
| Durability | 5000 | Cycles | Unloading, 10-20 cycles/minute |
| Temperature Range | -25 to +70 | Environmental use |
Detailed Test Conditions
| Item | Test Condition | Specification |
|---|---|---|
| Contact Resistance | Measured at 1KHz small current | 40 m MAX |
| Insulation Resistance | Applied DC500V for 1 minute | 100 M Min |
| Withstand Voltage | Applied AC500V (50/60Hz) for 1 minute | No breakdown |
| Insertion and Extraction Force | Measured with ergometer | 3-30 N |
| Terminal Strength | 500gf static force in one direction for 1 minute | No mechanical or electrical damage |
| Durability (Life Test) | 5000 cycles at a rate of 10-20 cycles per minute (unloading) | Contact Resistance 40 m MAX, Drive Force 3-30 N (initial value) |
| Soldering Test | Top of terminals dipped 2mm in solder bath at 2305 for 3 sec | - |
| Heat Test | 802 for 48 hours, then keep in normal condition for 30 minutes | Contact Resistance 50 m MAX, Insulation Resistance 100 M Min, No mechanical or electrical damage |
| Humidity Test | 402 and 90-95% RH for 48 hours, then keep in normal condition for 30 minutes | - |
| Cold Test | -302 for 48 hours, then keep in normal condition for 30 minutes | - |