SHOU HAN TYPE-C 16PLC-H10.0
Price:
Negotiable
MOQ:
20
Delivery Time:
1工作日
Brand:
TYPE-C 16PLC-H10.0
Product Description
Product Overview
This document outlines the specifications for the TYPE-C 16PLC-H10.0 connector from Shenzhen Shouhan Technology Co., Ltd. It details the product's mechanical, electrical, and durability characteristics, along with testing conditions and performance requirements.
Product Attributes
- Brand: SHENZHEN SHOUHAN TECHNOLOGY CO.,LTD
- Origin: Shenzhen, China
- Model: TYPE-C 16PLC-H10.0
- Part Number: 16PLC-H10.0
- Material Code: PRACTICAL
Technical Specifications
| Item | Test Conditions | Performance | |||
| Mechanical | Connection Force | Measurement shall be made after connecting and disconnecting using standard plug gauge 3 times. | PLUG GAUGE 3 | 0.5-2.0Kgf | |
| Disconnecti on Force | Measurement shall be made after connecting and disconnecting using standard plug gauge 3 times. | PLUG GAUGE 3 | 0.8-2.0Kgf | ||
| Terminal Strength | A static load of 0.1N/m(1kgf/cm)shall be applied to the tip of the terminal for 1 min in any direction. There shall be no damage to the terminal such as cracks, looseness or play. Electrical, and mechanical characteristics shall be satisfied. | 1 0.1N/m(1kgf/cm). | |||
| Electrical | Contact Resistance | Measured at small current (100mA or less) 1000Hz | 100 m A | 40m MAX | |
| Insulation Resistance | Apply a voltage of 100V DC for 1 min to following portions after which measurement shall be made: (1) Between body and conductor (2) Between conductors not to be contact (3) Between conductors not to be when plug is inserted | 100V DC 1 1 2 3 | 100M MIN | ||
| Dielectric Strength | AC 100V ims(50~60Hz)for 1 min Trip Current:0.5mA (1) Between body and conductor (2) Between conductors not to be contact (3) Between conductors not to be when plug is inserted | AC 100V 50Hz/min 1 0.5mA, : (1) (2) (3) | Without damage to parts arcing or breakdown etc | ||
| Durability | Solder- Ability Test | The top of the terminals shall be dipped 1mm in the solder bath of 2505 for 50.5 seconds. (1) Solder wetting time shall be 3 sec or less (2) The area of soldering should be over 75% | 1mm ,2505,5 0.5 13 275% | ||
| Resistance to Soldering Heat Test (Reflow Soldering) | Preheat: Temperature on the copper foil surface should reach 180.120s after the P.C.B entered into the soldering equipment. Tallest temperature: Temperature on the copper foil surface should reach the peak temperature of 2605 with in 20 seconds. | :180,120s :260520 | Without deformation of case or excessive looseness of terminals. Electrical characteristics shall be satisfied. | ||
| Resistance to Soldering Heat Test (Soldering Iron Method) | Bit temperature 3305 Application time of soldering iron 30.5 sec However excessive pressure shall not be applied to the terminal. | 3305 30.5 | Without deformation of case or excessive looseness of terminals. Electrical characteristics shall be satisfied. | ||
| Humidity Test | The jack shall be stored at a temperature of 402 and a humidity of 90%to 96% for 96 Hr,then the jack shall be maintained at standard atmospheric condition for 1 Hr for other procedures. | 402 90~96% Hr 96 1 | |||
| Heat Test | The jack shall be stored at a temperature of 702 for 96 hours, and then it shall be subjected to the controlled recovery measurement. | 70296 1 | There shall be no damage on appearance. Mechanical and electrical characteristics shall be satisfied. | ||
| Cold Test | The jack shall be stored at a temperature of -253 for 96 hours and then it shall be subjected to the controlled recovery conditions for 1 hour after which. | -25396 1 | There shall be no damage on appearance. Mechanical and electrical characteristics shall be satisfied. | ||
| Life Test (Without Load) | Connection and disconnection shall be made with the mating plugs and jacks for 5000 cycles at a speed of 10 to 25 cycles/min. | Plug()1 10-255000 | (1) Contact resistance shall be 0.1 (2) Disconnection force shall be 0.8 to 2.0N (3) Mechanical and electrical characteristics shall be satisfied. | ||
| Life Test (Load) | At rating condition (non-inductive load) connection and disconnection shall be made 5000 cycles at a speed 10 to 20 cycles / min. | ()1 10-205000 | (1) Contact resistance shall be 0.1 (2) Disconnection force shall be 0.8 to 2.0N (3) Mechanical and electrical characteristics shall be satisfied. | ||
| Temperature Cycling Test | The jack shall be subjected to 5 cycles of the following conditions, and then shall return to room ambient condition for 30 minutes. | 5 30 | Product cannot deform or crack. Insertion & Extraction Force: 3 to 20N. Contact Resistance: Max.30m. Insulation Resistance: Min.100 M. Dielectric Withstanding Voltage: 100VAC/min (between terminals). | ||
| Cold & Heat Shock Test | The jack shall be subjected to 5 cycles of the following conditions, and then shall return to room ambient condition for 30 minutes. | 5 30 | Product cannot deform or crack. Insertion & Extraction Force: 3 to 25N. Contact Resistance: Max.30m. Insulation Resistance: Min.100 M. Dielectric Withstanding Voltage: 500VAC/min (between terminals). |
Similar Products