ABB 1SFA898110R7000 softstarter PSTX142-600-70 has a rated maximum operational current of 142 A with an operating voltage span from 208...600 V AC
Price:
Negotiable
MOQ:
1
Delivery Time:
5-8DAYS
Brand:
ABB
Product Description
ABB PSTX142-600-70 Softstarter
The ABB 1SFA898110R7000 PSTX142-600-70 softstarter delivers reliable motor control with a rated maximum operational current of 142 A and operating voltage range of 208-600 V AC.
Key Specifications
Rated Operational Current
142 A
Operating Voltage
208-600 V AC
Horsepower Rating (UL/CSA)
40-125 Hp (depending on voltage)
Degree of Protection
IP00 (Main Terminals)
Ordering Information
Minimum Order Quantity
1 piece
Customs Tariff Number
85371091
Technical Documentation
- Data Sheet, Technical Information: Softstarter main catalog
- PSTX quick start guide
- PSTX - Installation and commissioning manual
- Softstarter Handbook
- CAD Dimensional Drawing: 2D and 3D files for CAD systems
- EPLAN Data: EPLAN EDZ PSTX142
Physical Dimensions
| Dimension | Value |
|---|---|
| Width | 199 mm |
| Height | 377 mm |
| Depth/Length | 283.3 mm |
| Weight | 7 kg |
Electrical Specifications
| Parameter | Specification |
|---|---|
| Rated Operational Voltage | 208-600 V AC |
| Control Supply Voltage | 100-250 V AC |
| Control Circuit Voltage | 24 V DC |
| Rated Frequency | 50/60 Hz |
| Starting Capacity | 4xIe for 10s |
| Ramp Time | 1-120 seconds |
Power Ratings
In-Line Connection
| Voltage | Power | Current |
|---|---|---|
| 230 V | 37 kW | 142 A |
| 400 V | 75 kW | 142 A |
| 500 V | 90 kW | 142 A |
Inside Delta Connection
| Voltage | Power | Current |
|---|---|---|
| 230 V | 75 kW | 245 A |
| 400 V | 132 kW | 245 A |
| 500 V | 160 kW | 245 A |
Control & Communication Features
Communication Protocols: Modbus-RTU, Modbus-TCP, Ethernet-IP, EtherCAT, DeviceNet, CANopen, Profibus, Profinet, BACnet-IP, BACnet-MSTP
Analog Outputs: 0-10 V, 0-20 mA, 4-20 mA
Signal Relays: Run, By-pass, Fault, Overload
LED Indicators: Ready to Start (Green), Running (Green), Protection (Yellow), Fault (Red)
Analog Outputs: 0-10 V, 0-20 mA, 4-20 mA
Signal Relays: Run, By-pass, Fault, Overload
LED Indicators: Ready to Start (Green), Running (Green), Protection (Yellow), Fault (Red)
Protection Functions
Built-in electronic overload protection, phase reversal protection, voltage/current imbalance protection, earth fault protection, under/over voltage protection, locked rotor protection, and user-defined protection functions.
Environmental Specifications
| Condition | Temperature Range |
|---|---|
| Operation | -25°C to +60°C |
| Storage | -40°C to +70°C |
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
Location
F1-803, Guorun Silu Jin Rong Zhongxin, Qindu District, Xianyang City, Shaanxi Province
Contact Person
Leon Lee