Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
                                                                                                           
Verified Supplier
8 Years
Since 2018
Menu

ABB 1SFA898116R7000 Softstarter PSTX60-600-70 Has A Rated Max Operational Current Of 60A

Price Negotiable
Price: Negotiable
MOQ: 1
Delivery Time: 5-8DAYS
Brand: ABB
Product Description
ABB PSTX60-600-70 Softstarter
The ABB 1SFA898116R7000 PSTX60-600-70 softstarter delivers reliable motor control with a rated maximum operational current of 60 A and operating voltage range from 208-600 V AC.
Ordering Information
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85371091
Technical Documentation
Data Sheet & Technical Information:
Softstarter main catalog
Quick Start Guide:
PSTX quick start guide
Installation Manual:
PSTX - Installation and commissioning manual
Technical Handbook:
Softstarter Handbook
CAD Files:
2D and 3D files for CAD systems
EPLAN Data:
EPLAN EDZ PSTX470
Physical Dimensions
Dimension Value
Width 361 mm
Height 493 mm
Depth/Length 282 mm
Weight 25 kg
Electrical Specifications
Parameter Specification
Rated Operational Voltage 208 ... 600 V AC
Rated Control Supply Voltage (Us) 100 ... 250 V AC
Rated Control Circuit Voltage (Uc) 24 V DC
Rated Frequency (f) 50/60 Hz
Rated Operational Current - In-Line Connection (Ie) 470 A
Rated Operational Current - Inside Delta Connection 814 A
Power Ratings
In-Line Connection
Voltage Power Rating
230 V 132 kW
400 V 250 kW
500 V 315 kW
Inside Delta Connection
Voltage Power Rating
230 V 250 kW
400 V 450 kW
500 V 600 kW
Operational Features
Service Factor
100%
Overload Protection
Built-in electronic overload protection
Integrated Electronic Overload
Yes
Starting Capacity
4xIe for 10s
Ramp Time
1 ... 120 seconds
Initial Voltage During Start
10 ... 99%
Step Down Voltage Special Ramp
100 ... 10%
Control & Signaling
Switch for Inside Delta Connection
Yes
Run Signal Relay
Yes
By-pass Signal Relay
Yes
Fault Signal Relay
Yes
Overload Signal Relay
Yes
LED Status Indicators
Indicator Color Status
Ready to Start/Standby Green ON
Running Green R
Protection Yellow Active
Fault Red Active
Communication Protocols
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
Protection & Safety
Degree of Protection
IP00 (Main Terminals) acc. to IEC 60529, IEC 60947-1, EN 60529
Key Functions
  • Auto phase sequence detection
  • Automatic restart
  • Current limit
  • Current limit ramp
  • Dual current limit
  • Dynamic brake
  • Electricity metering
  • Electronic overload Time-to-cool
  • Emergency mode
  • Event log
Protection Functions
  • Bypass open protection
  • Current imbalance protection
  • Current underload protection
  • Dual overload (separate overload for start and run)
  • Earth fault protection / ground fault protection
  • Electronic overload protection, EOL
  • Extension IO failure protection
  • Fieldbus failure protection
  • HMI failure protection
  • Locked rotor protection
  • Max number of starts/hour
  • Over voltage protection
  • Phase reversal protection
  • Power factor underload protection
  • PT-100 connection
  • PTC connection
  • Too long current limit protection
  • Too long start time protection
  • Under voltage protection
  • User defined protection
  • Voltage imbalance protection
Warning System
  • Current imbalance warning
  • Current underload warning
  • Electronic overload Time-to-trip
  • EOL warning
  • Faulty fan warning
  • Locked rotor warning
  • Motor runtime limit warning
  • Over voltage warning
  • Phase loss warning (for standby)
  • Power factor underload warning
  • Short circuit warning (for Limp mode)
  • THD(U) - Total Harmonic Distortion warning
  • Thyristor overload warning (SCR)
  • Under voltage warning
  • Voltage imbalance warning

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
Location F1-803, Guorun Silu Jin Rong Zhongxin, Qindu District, Xianyang City, Shaanxi Province
Contact Person Leon Lee

Request A Quote

Please check your email address.
Your message must be at least 20 characters.