Leilang Electric Group CO.,LTD
                                                                                                           
Verified Supplier
19 Years
Since 2007
Menu

167 KVA Medium Voltage Transformers 12.47V Low TCO Single Phase Transformer

Price Negotiable
Price: $1000-$10000
MOQ: 1unit
Delivery Time: 30days
Brand: Leilang Electric
Product Description
167 kVA Single Phase Pad Mounted Transformer | 12.47V, Multiple Safety Protections, Low TCO
Product Overview

Leilang Electric 167 kVA single-phase pad-mounted transformer is a high-capacity utility-grade power distribution solution purpose-built for North American 12.47kV grid systems, delivering industry-leading safety and exceptional long-term value. Designed to step down 12470GrdY/7200V primary voltage to standard 120/240V secondary power, this unit features a comprehensive multi-layer safety protection system that eliminates operational risks and ensures reliable power delivery in high-demand environments.

Engineered for ultra-low total cost of ownership (TCO), it achieves an impressive 99.33% overall efficiency with only 425W no-load loss and 1733W load loss, significantly reducing energy expenses over its 25+ year service life. Built with a robust Compartmental-Type II dead-front enclosure and 100% high-purity copper windings, it requires minimal maintenance and exhibits exceptional durability in extreme outdoor conditions. Fully certified to ANSI/IEEE C57, CSA and DOE 2016 standards, it is ideal for high-density residential communities, medium-sized commercial centers and light industrial facilities.

Leilang Electric 167 kVA single-phase pad-mounted transformer exterior view
Key Specifications
Parameter Value
Rated Capacity 167 kVA
Primary Voltage 12470GrdY/7200V (customizable to 13.8kV/34.5kV)
Secondary Voltage 120/240V (L-N-L)
Frequency 60 Hz
No-Load Loss 425W
Load Loss 1733W
Efficiency 99.33%
Short-Circuit Impedance 3.5% Typical
Winding Material 100% High-Purity Copper
Cooling Method ONAN (Self-Cooled)
Insulation Class Class E (120°C)
Structure Compartmental-Type II, Dead-Front
Feed Type Loop Feed (radial feed optional)
Tap Changer 5-position hot-stick operable (±2*2.5%)
Sound Level ≤55 dBA
Protection Bayonet fuses, surge arresters, pressure relief valve
Certification ANSI/IEEE C57, UL/cUL, CSA, DOE 2016
Ambient Temperature Range -40°C to +40°C
Dimensions (W*D*H) 55.12" * 45.67" * 33.07" (1400*1160*840 mm)
Oil Weight 727.5 lb (330 kg)
Total Weight 2976 lb (1350 kg)
Core Features & Benefits
Comprehensive Multiple Safety Protections
  • Dead-front compartmental design: All high-voltage components are fully enclosed and insulated, eliminating all exposed live parts
  • Automatic pressure relief valve: Instantly releases internal pressure in case of fault, preventing catastrophic failure
  • Bayonet expulsion fuses: Fast-acting overcurrent protection that isolates faults without interrupting the entire grid
  • Integrated surge arresters: Protects against lightning strikes and transient voltage surges
  • Tamper-proof security system: Captive penta-head bolts and floating nut design prevent unauthorized access and vandalism
  • Dedicated grounding provisions: Ensures proper electrical grounding for maximum personnel safety
  • Meets IEEE C57.12.28 enclosure integrity standards: Withstands extreme weather and physical impact
Industry-Leading Low Total Cost of Ownership
  • 99.33% ultra-high efficiency: Exceeds DOE 2016 standards by 2.5%, saving over 3,500 kWh of electricity annually
  • Minimal maintenance requirements: Fully sealed design eliminates internal cleaning; only annual visual inspections needed
  • 25+ year service life: High-quality materials and robust construction ensure long-term reliability
  • Low failure rate: Rigorous factory testing reduces unplanned downtime and repair costs
  • No substation required: Eliminates expensive civil engineering and construction costs
  • Energy rebate eligible: Qualifies for most utility energy efficiency rebate programs across North America
Native 12.47kV North American Grid Compatibility
  • Standard 12.47kV primary voltage: Directly compatible with the most widely used distribution voltage in North America
  • 5-position voltage tap changer: Compensates for line voltage fluctuations to ensure stable power delivery
  • Supports both loop and radial feed systems: Flexible deployment options for different network configurations
  • ANSI/IEEE C57 compliant: Built to exact utility industry specifications for seamless integration
Durable & Weather-Resistant Construction
  • Corrosion-resistant coated steel enclosure: Withstands rain, snow, dust and UV radiation
  • Domed top surfaces: Prevents water retention and rust formation
  • Stainless steel hardware: Eliminates corrosion on critical components
  • Electrical grade mineral oil with oxidation inhibitor: Extends insulation life and improves thermal performance
Easy Installation & Serviceability
  • Factory pre-wired and tested: Arrives ready for immediate cable connection
  • All service points ground-accessible: No aerial equipment required for maintenance
  • Threaded stainless steel lifting provisions: Simplifies transportation and installation
  • Laser-engraved aluminum nameplate: Permanent identification with all technical specifications
Typical Applications
  • High-density residential neighborhoods and apartment complexes
  • Medium-sized commercial centers, supermarkets and shopping malls
  • Office buildings and professional campuses
  • Schools, hospitals and healthcare facilities
  • Light industrial facilities and manufacturing plants
  • Data centers and telecommunications hubs
  • Underground utility distribution networks
Pad-mounted transformer installation and connection details Internal components and safety features of pad-mounted transformer
Frequently Asked Questions (FAQ)
What specific safety protections does this 167 kVA transformer include?
Leilang Electric's 167 kVA transformer features a comprehensive safety system including dead-front fully insulated construction, automatic pressure relief valve, bayonet expulsion fuses, surge arresters, tamper-proof penta-head locking system and dedicated grounding provisions. It fully complies with IEEE C57.12.28 enclosure integrity standards.
How does this transformer deliver a low total cost of ownership?
It achieves 99.33% ultra-high efficiency, saving over 3,500 kWh annually. Its fully sealed design requires only annual visual inspections, and the 25+ year service life minimizes replacement costs. No dedicated substation is needed, eliminating expensive construction expenses.
Is this transformer directly compatible with 12.47kV utility grids?
Yes. It is specifically engineered for the 12470GrdY/7200V standard distribution system used across most of North America. It fully complies with all ANSI/IEEE C57 utility standards and can be directly connected to existing 12.47kV networks.
What is the energy efficiency of this transformer?
It delivers an impressive 99.33% overall efficiency with only 425W no-load loss and 1733W load loss. This exceeds DOE 2016 federal requirements and qualifies for most utility energy rebate programs, resulting in significant long-term cost savings.
What maintenance does this transformer require?
Its fully sealed, self-cooling design requires only annual visual inspections of the oil level, enclosure condition and security seals. No routine internal maintenance is needed for the first 10 years of operation, and all service points are easily accessible from ground level.
What is the standard lead time and warranty coverage?
Standard 167 kVA units ship within 15-25 business days. All Leilang Electric transformers come with a 24-month comprehensive warranty from the date of shipment, covering all manufacturing defects. We also provide free lifetime technical support.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Leilang Electric Group CO.,LTD
Location No. 2200, Zhude Road, Jiading District, Shanghai, China
Contact Person Alice Qin

Request A Quote

Please check your email address.
Your message must be at least 20 characters.