Multi Core PVC Insulated Electrical Cable 4x2.5mm² 0.6/1kV Rated Voltage Flame Retardant

Price Negotiable
Price: Negotiable
MOQ: Negotiable
Delivery Time: Negotiable
Product Description
Multi Core PVC Insulated Kabel NYA NYM 4x2.5 Electrical Cable
Multi Core PVC Insulated Kabel NYA NYM 4x2.5 Electrical Cable Suppliers in UAE
Product Name Copper core or aluminum core XLPE insulated PVC sheathed power cable
Copper core or aluminum core XLPE insulated steel tape armoured PVC sheathed power cable
Copper core or aluminum core XLPE insulated steel wire armoured PVC sheathed power cable
Rated Voltage 0.6/1kV, 1.8/3kV, 3.6/6kV, 6/10kV, 8.7/15kV, 12/20kV, 21/35kV, 26/35kV
Standard B/T12706-2008, GB/T12703-200, IEC60502-1-1997
Model YJV, YJLV, YJV22, YJLV22, YJV32, YJLV32, YJV42, YJLV42
Armoured Steel tape armored, steel wire armored
Double galvanized steel tape or galvanized steel wire for three core power cable
Double aluminium tape or aluminium wire for single power cable
Number of Cores Single core, 2 cores, 3 cores, 4 cores, 5 cores, 3+1 cores, 3+2 cores, 4+1 cores, etc.
Common Size 1mm², 1.5mm², 2.5mm², 4mm², 6mm², 10mm², 16mm², 25mm², 35mm², 50mm², 70mm², 95mm², 120mm², 150mm², 185mm², 240mm², 300mm², 400mm², 500mm², 630mm², 800mm², 1000mm², etc.
Types Ordinary type, flame-retardant type, fire-resistant type, low-smoke halogen-free type
Application Power distribution engineering, power transmission engineering, electromechanical and hydropower installation engineering, power transmission, power supply installation system, control system, etc.
Installation Precautions
  1. The minimum bending radius when laying the cable is not less than 10 times the outer diameter of the cable.
  2. YJV / YJLV cables are laid indoors, in channels and pipes, and can also be buried in loose soil, which cannot bear external forces.
  3. The YJV22 / YJLV22 cables are laid underground and can withstand external mechanical forces, but cannot withstand large tensile forces.
  4. Special tools should be used for cable laying, such as pay-off racks, guide rollers, etc., to prevent mechanical damage during the laying process and keep away from heat sources.
  5. When laying the cable through the pipe, the inner diameter of the pipe should not be less than 1.5 times the outer diameter of the cable. It is forbidden to squeeze the cable when passing through the pipe. The total area of the cable should not exceed 40% of the total area of the pipe.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Minfeng Cable Group Co., Ltd
Location Room 3101, Huafa International Building, Hanyang District, Wuhan City, Hubei Province.
Contact Person Fannie Fang

Request A Quote

Please check your email address.
Your message must be at least 20 characters.