DLAS Laser FID Hydrocarbon Process Gas Analyzer for O2 CO NH3 CO2 Monitoring 0-100%Vol
Price:
USD2000-10000
MOQ:
1 Unit
Delivery Time:
10-15 working days
Brand:
JUGE
Product Description
Fast Response Laser Gas Analyzer for O2 Co Nh3 CO2 Gas Monitoring and Analysis
Overview
The AG-TDL07 Laser Gas Analyzer is developed for industrial on-line analyzing and online environmental monitoring. Based on semiconductor laser absorption spectroscopy (DLAS) technology, it features an integrated design with high level of integration.
Available in various configurations including in-situ probing type, by-pass type, multi-channel and disc-mounted type, the analyzer can measure gases such as O2, CO, NH3, CO2, CH4, H2O, HC, HF, and others. It supports both macro-analysis and micro-analysis concentration measurements of target gases.
Features
- Utilizes DLAS technology for in-situ online gas analysis
- Double proof probe design without positive pressure purge, no additional data processing unit, simple compact structure with high reliability
- Uses high-power lasers without fiber coupling, suitable for harsh working conditions (such as excessive dust environments)
- Incorporates patented spot light path adjustment technology for easy on-site installation
Main Process Line
Technical Parameters
| Measurement Principle | Tunable Laser Absorption Spectroscopy (TDLAS) |
| Linearity Error | ≤±1% F.S. |
| Span Drift | ≤±1% F.S./6 months |
| Repeatability | ≤1% F.S. |
| Calibration Period | ≤1 time/6 month |
| Explosion-proof Grade | Ex d IIC T6 |
| Protection Levels | IP65 |
| Warming-up Time | ≤15 min |
| Response Time (T90) | ≤1s |
| Analog Outputs | 2-wire 4-20mA signal output (Isolated, maximum load 750Ω) |
| Analog Inputs | 2-way 4-20mA input (temperature-pressure compensation) |
| Digital Outputs | RS485/RS232/GPRS/Bluetooth |
| Relay Output | 3-wire relay (24V, 1A) |
| Ambient Temperature | -30ºC to +60ºC |
| Gas Jet | 0.3-0.8MPa Industrial nitrogen inlet and purification instrument gases etc. |
| Power | 220VAC, power based on specific configuration |
| Installation Method | Sampling probe mounted in the flue/pipe, system installed nearby |
Gas Detection Limits
| Detection Gas Type | Detection Limit | Detection Range |
|---|---|---|
| O2 | 0.01% Vol. | (0-1)% Vol., (0-100)% Vol. |
| CO2 | 10 ppm | (0-1000) ppm, (0-100)% Vol. |
| H2S | 20 ppm | (0-2000) ppm, (0-100)% Vol. |
| HCl | 0.1 ppm | (0-50) ppm, (0-100)% Vol. |
| NH3 | 0.1 ppm | (0-10) ppm, (0-100)% Vol. |
| C2H2 | 0.1 ppm | (0-10) ppm, (0-100)% Vol. |
| CO | 10 ppm | (0-1000) ppm, (0-100)% Vol. |
| H2O | 0.3 ppm | (0-50) ppm, (0-100)% Vol. |
| HF | 0.02 ppm | (0-5) ppm, (0-10000) ppm |
| HCN | 0.3 ppm | (0-30) ppm, (0-1)% Vol. |
| CH4 | 0.4 ppm | (0-40) ppm, (0-100)% Vol. |
| C2H4 | 0.6 ppm | (0-60) ppm, (0-100)% Vol. |
Remark 1: The test conditions for 1m optical path, gas pressure 1bar, gas temperature 300K
Remark 2: By increasing the optical path, proportionally lower detection limit
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Nanjing Juge Environmental Technology Co., Ltd.
Location
Building 17, No. 99 Guangli Road, Moling Subdistrict, Jiangning District, Nanjing, Jiangsu
Contact Person
Leon Chen