ETO Gas Detector Fixed Ethylene Oxide Sterilization Safety Monitoring System Industrial Toxic Gas Alarm Gas Sensor
Our company's online gas detector utilizes original imported smart gas sensors, serving as an intelligent, high-performance instrument capable of continuous online monitoring of combustible gases, toxic/hazardous gases, and specialty gases.
Featuring an integrated flameproof enclosure structure, the detector delivers high sensitivity and precision. Through connection to a GDS gas alarm controller and monitoring management software, it enables real-time concentration display on computers. Additionally, by incorporating an optional wireless module, real-time monitoring data and alarm status can be transmitted to safety control centers.
>>Main technical parameters
| Detection Principle | Constant potential electrolysis, NDIR infrared optics, Catalytic combustion, PID photoionization, Laser TDLAS |
| Measuring Range | 0-10, 0-100, 0-1000 (Customizable range) |
| Unit | PPM, mg/m³, LEL%, VOL%, etc. |
| Resolution |
0.1,0.01,0.001 |
| Sampling Method |
Free diffusion type – Online continuous detection with free diffusion method. |
| Installation Method |
Wall-mounted; Pipeline-mounted (clamp-on or insertion type, with external threads) |
| Indication Error | ≤±3% F.S |
| Repeatability | ≤±2% (F.S/year) |
| Zero Drift | ≤±1% (F.S/year) |
| Response Time |
≤20 seconds (T90) (higher requirements depend on sensor performance) |
| Recovery Time |
≤10 seconds (T90) (higher requirements depend on sensor performance) |
| Power Supply | 12-36 VDC |
| Power Consumption |
≤2.5 W (at DC24V) |
| Environmental Pressure |
80 kPa ~ 120 kPa |
| Environmental Temperature |
-30℃~+50℃ (Typical), -40℃~+80℃ (Limit) |
| Environmental Humidity |
10%~95% RH (non-condensing) |
| Main Material |
① Housing: ADC12 aluminum alloy with Teflon paint finish, wear/corrosion-resistant (316L stainless steel housing optional for harsh environments) ②Gas Chamber: High-strength, wear/corrosion-resistant aluminum profile; External thread M351.5 |
| Output Signal |
① 3-wire 4-20mA current output (compatible with controllers, PLC, DCS) ② RS-485 digital output ③ 2 relay alarm outputs (high/low segments): Passive contact, 30V 1A / 125VAC 0.5A |
| Signal Transmission |
Shielded three-core (or four-core) cable; maximum transmission distance: 1000-2000 meters |
| Alarm Method |
Audible and visual alarm (optional, alarm sound <90 dB) |
| Direct Reading |
Measured value, max/min values |
| Data Download |
RS485 serial port for data export |
| Calibration |
2-4 point calibration; customizable calibration values |
| Explosion-proof Electrical |
① M20 internal thread (Optional: 1/2"NPT, G3/4, G1/2 internal threads) ② Explosion-proof cable gland (Optional, certified) |
| Explosion-proof Mark |
Ex db ib IIC T6 Gb,Ex ib tb IIIC T80°C Db |
| Protection Level |
IP66 |
| Dimensions |
180 mm (H) × 140 mm (W) × 92 mm (D) |
| Weight |
Approx. 1.6 kg (aluminum alloy housing) |
| Compliance Standards |
GB15322.1-2003, GB3836.1-2010, GB3836.2-2010 |
| Quality Assurance |
1-year warranty; free repair during warranty period |
>>List of Commonly Detected Gas Types
|
NO |
Detection |
Range |
Accuracy |
T90 Response time |
Resolution |
Alarm set point (low/high) |
|
1 |
PH3 |
0 – 5 ppm |
±5% (F.S) |
≤ 25 s |
0.01 ppm |
0.3 ppm/5 ppm |
|
2 |
O2 |
0-30%Vol |
±5% (F.S) |
≤ 15 s |
0.10% Vol |
18.0%Vol/23.0%Vol |
|
3 |
EX |
0-100% LEL |
±5% (F.S) |
≤ 15 s |
1% LEL |
25.0%/50.0% LEL |
|
4 |
CO |
0 - 2000 ppm |
±5% (F.S) |
≤ 25 s |
1 ppm |
50 ppm/100 ppm |
|
5 |
H2S |
0 -100 ppm |
±5% (F.S) |
≤ 30 s |
1 ppm |
10 ppm/20 ppm |
|
6 |
SO2 |
0 - 100 ppm |
±5% (F.S) |
≤ 30 s |
0.1 ppm |
2 ppm /10 ppm |
|
7 |
CI2 |
0 - 20 ppm |
±5% (F.S) |
≤ 30 s |
0.1 ppm |
1 ppm /10 ppm |
|
8 |
NH3 |
0 – 200 ppm |
±5% (F.S) |
≤ 50 s |
1 ppm |
25 ppm /50 ppm |
|
9 |
NO2 |
0 - 20 ppm |
±5% (F.S) |
≤ 25 s |
0.1 ppm |
3 ppm/10 ppm |
|
10 |
NO |
0 - 250 ppm |
±5% (F.S) |
≤ 60 s |
1 ppm |
25 ppm/50 ppm |
|
11 |
H2 |
0 - 1000 ppm |
±5% (F.S) |
≤ 60 s |
1 ppm |
50 ppm /100 ppm |
|
12 |
HCN |
0 - 50 ppm |
±5% (F.S) |
≤ 200 s |
0.1 ppm |
10 ppm /20 ppm |
|
13 |
HCL |
0 - 20 ppm |
±5% (F.S) |
≤ 60 s |
0.1 ppm |
5 ppm /10 ppm |
|
14 |
CH4 |
0 - 5% Vol |
±5% (F.S) |
≤ 60 s |
0.1% Vol |
customized |
|
15 |
CO2 |
0 - 5% Vol (0-5000ppm) |
±5% (F.S) |
≤ 60 s |
0.01% Vol (1 ppm) |
customized |
|
16 |
PID(VOCs) |
1-1999 ppm |
±5% (F.S) |
≤ 20 s |
0.1 ppm |
customized |
|
17 |
C3H8 |
0 - 5%Vol |
±5% (F.S) |
≤ 60s |
0.01% Vol |
customize |
|
18 |
O3 |
0 – 5 ppm |
±5% (F.S) |
≤ 30s |
0.02 ppm |
1ppm/2 ppm |
|
19 |
SF6 |
0 – 1000 ppm |
±5% (F.S) |
≤ 60s |
0.2ppm |
25ppm/50 ppm |
|
20 |
HF |
0 – 10 ppm |
±5% (F.S) |
≤ 60s |
0.1ppm |
3ppm/10 ppm |
Remark: Customized alarm setting points and detection ranges are also available.