Modular Online CEMS Continuous Emission Monitoring System For SO2 NO NO2 CO CO2 Gas Analyzer
Overview

This comprehensive monitoring system consists of multiple integrated subsystems: gaseous pollutant monitoring, particulate matter monitoring, flue gas parameter monitoring, and data acquisition and processing. It provides continuous monitoring of critical parameters including dense flue gas flow rate, SO2, NOx, O2, CO, CO2, HCL, HF, NH3, flue gas pressure, and flue gas humidity.

The system calculates emission rates, total emissions, and effectively manages measured data with real-time transmission, remote fault diagnosis, report statistics, and graphical data analysis capabilities, enabling unattended site operation. Featuring a simple structure, wide dynamic range, strong real-time performance, flexible networking, and low operating costs, the modular design allows easy configuration according to customer requirements and seamless integration with internal DCS and environmental protection department data systems.

Key Features
  • High Reliability: Pulsed xenon lamp light source with ten-year lifespan; grating spectroscopy and array sensors with no moving parts; integrated design dust monitor with compact structure
  • Convenient Maintenance: Simple system wiring for easy installation and maintenance; fiber optic connections between light source, gas chamber and spectrometer enable simple part replacement with low costs
  • High Measurement Accuracy: SO2 and NOx analysis using Differential Optical Absorption Spectroscopy (DOAS); effectively compensates for water, dust and other measurement influences; laser backscattering dust measurement with high sensitivity, fast response, built-in self-calibration, and stable performance
Main Technical Parameters
Project Indicators
Measurement standard SO2, NOx, NO, NO2, O2, CO, CO2, NH3, HCL, HF, Dust, Temperature, Pressure, Flow
Measuring method SO2, NOx, NO, NO2: UV (DOAS)
CO, CO2: NDIR
O2: ECD/Zirconia/Paramagnetic oxygen
HCL, HF, H2S, CO, O2: TDLAS
Dust: Laser back scattering/Laser forward scattering backscattering
Temperature: PT100
Pressure: Diffused silicon
Flow: Pitot tube/Ultrasonic
Detection range SO2, NOx, NO, NO2: 0~100ppm, 0~5000ppm
O2, CO, CO2: 0~50ppm, 0~100%
NH3, HCL, HF, H2S: 0~10ppm, 0~500ppm
Dust: 0~10mg/m³, 0~5000mg/m³
Temperature: 0~300℃, 0~500℃
Pressure: -10kPa~+10kPa
Flow: 0-40m/s
Resolution ratio ≤ ±0.1%
Accuracy SO2, NOx, NO, NO2: ≤ ±1.5%FS
O2, CO, CO2: ≤ ±2%FS
NH3, HCL, HF, H2S: ≤ ±1%FS
Repeatability ≤2%FS
Zero drift ≤2%FS
Range drift ≤2%FS
Flow 1.5~2.0 L/min
Response time T90≤50s (Analyzer)
Sampling probe temperature 120~180℃
Compressed air source (0.4~0.8)MPa, 0.25m³/min, Clean and oil-free
Working power AC220V±10%, 50HZ, 3000W
Work environment -5℃~+45℃; Humidity ≤ 90% RH
Cabinet size 800*750*1900mm
Signal transmission RS485, 4-20mA
Protection level Cabinet IP45, Customizable outdoor cabinets
System Composition
CEMS Online SO2 NO NO2 Continuous Emission Monitoring System Flue Gas Analyzer configuration and components
CEMS Online SO2 NO NO2 Continuous Emission Monitoring System Flue Gas Analyzer installation and operation
Related Videos

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Nanjing Juge Environmental Technology Co., Ltd.
Location Building 17, No. 99 Guangli Road, Moling Subdistrict, Jiangning District, Nanjing, Jiangsu
Contact Person Leon Chen

Request A Quote

Please check your email address.
Your message must be at least 20 characters.