Nanjing Inste Automation Co., Ltd.
                                                                                                           
Verified Supplier
11 Years
Since 2015
Menu

High Precision 4-20mA Magnetic Flow Meter Transmitter Electromagnetic Digital Flow Meter

Price Negotiable
Price: USD200-800/ set
MOQ: 1 set
Delivery Time: 2-3 word days
Brand: INSTE
Product Description
High Precision 4-20mA Magnetic Flow Meter Transmitter Electromagnetic Digital Flow Meter
Product Overview

DN80 Smart Electromagnetic Flow Meter: High-Precision ±0.5% Accuracy with 4-20mA Output

Product Introduction

Our DN80 Electromagnetic Flow Meter is a high-performance, industrial-grade solution designed for precise liquid measurement. Built with advanced electromagnetic induction technology, this magmeter provides exceptional reliability for water treatment, chemical processing, and various industrial applications.

Key Features
1. High-Precision Measurement (±0.5% Accuracy)

Accuracy is critical in industrial automation. This electromagnetic flow meter features a sophisticated signal processing algorithm that ensures stable measurement with an accuracy of ±0.5% of reading.

  • Reliable Data: Minimized drift and high repeatability for billing and process control
  • Wide Range: Maintains precision across a broad flow velocity range, ensuring every drop is accounted for
2. Standard DN80 (3-Inch) Robust Design

The DN80 (80mm) size is the industry standard for medium-sized pipelines.

  • Full Bore Construction: No moving parts inside the pipe, meaning zero pressure loss and no risk of mechanical wear
  • Corrosion Resistance: Available with PTFE or Rubber linings and SS316L or Hastelloy electrodes to handle everything from tap water to corrosive acids
3. Seamless Integration (4-20mA & Smart Output)

Designed for the modern smart factory, our electromagnetic flow transmitter offers versatile connectivity:

  • Industry Standard 4-20mA Output: Easy integration with PLC, DCS, and SCADA systems for real-time monitoring
  • Pulse & Digital Communication: Supports Pulse output for totalizer functions and RS485 MODBUS / HART for remote configuration and diagnostics
Technical Specifications
Parameter Specification
Product Name High Precision 4-20mA Magnetic Flow Meter Transmitter Electromagnetic Digital Flow Meter
Nominal Diameter DN80 (3 Inch)
Accuracy ±0.5% of reading
Output Signal 4-20mA
Communication RS485 Modbus RTU / HART
Power Supply AC220V / DC24V / 3.6V Battery Operated
Lining Material PTFE / Neoprene / F46
Electrode Material SS316L / Hastelloy C / Titanium / Tantalum
Protection Class IP65 (Standard) / IP68 (Waterproof)
Parameter Configuration

The L_MagB features 54 configurable parameters that allow users to customize every aspect of the device operation. The comprehensive parameter list is shown below:

Code Parameter Setting Way Grades Range
1 Language Select 2 English
2 Comm Address Set count 2 0~99
3 Baud Rate Select 2 300~38400
4 Sensor Size Select 2 3~3000
5 Flow Unit Select 2 L/h, L/m, L/s, m³/h, m³/m, m³/s
6 Flow Range Set count 2 0~99999
7 Flow Response Select 2 1~50
8 Flow Direction Select 2 Plus/Reverse
9 Flow Zero Set count 2 0~±9999
10 Flow Cutoff Set count 2 0~599.99%
11 Cutoff Enable Select 2 Enable/Disable
12 Total Unit Select 2 0.001m³~1m³, 0.001L~1L
13 SigmaN Enable Select 2 Enable/Disable
14 Analog Type Select 2 0~10mA / 4~20mA
15 Pulse Type Select 2 Frequency / Pulse
16 Pulse Factor Select 2 0.001m³~1m³, 0.001L~1L
17 Frequency Max Select 2 1~5999 Hz
18 MTSensor Enable Select 2 Enable/Disable
19 MTSensor Trip Set count 2 59999%
20 Alarm High Enable Select 2 Enable/Disable
21 Alarm High Value Set count 2 000.0~599.99%
22 Alarm Low Enable Select 2 Enable/Disable
23 Alarm Low Value Set count 2 000.0~599.99%
24 System Alarm Enable Select 2 Enable/Disable
25 Clear Sum Key Set count 3 0~99999
26 Sensor Code 1 User set 4 Finished Y M
27 Sensor Code 2 User set 4 Product number
28 Field Type Select 4 Type1,2,3
29 Sensor Factor Set count 4 0.0000~5.9999
30 Line CRC Enable Select 2 Enable/Disable
31-54 Additional configuration parameters for linearity correction, totalizers, password security, and factory settings
Password Security System

Parameters of converters determine the running status, process and output ways as well as state of output. Correct option and setting of parameters can keep the converters running optimally and achieve higher accuracies in both display and measurement.

Six-Grade Password System:

  • Grade 1 (Manufacturer set: 00521): Read-only access to parameters
  • Grade 2 (Manufacturer set: 03210): Can change parameters 1-24
  • Grade 3 (Manufacturer set: 06108): Can change parameters 1-25
  • Grade 4 (Manufacturer set: 07206): Can change parameters 1-38
  • Grade 5 (Fixed): Can change parameters 1-52
  • Grade 6: Manufacturer-only access

Users can reset passwords for grades 1-4 using grade 5 access. Grade 4 is primarily used for resetting total volume, while grades 1-3 can be assigned to different personnel based on user requirements.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Nanjing Inste Automation Co., Ltd.
Location East Mozhou Road , Nanjing ,Jiangsu , China
Contact Person Qi

Request A Quote

Please check your email address.
Your message must be at least 20 characters.