Safety Electromagnetic Flow Meter 20mA PTFE PFA F46 Liner Material DN200-DN400 EMF Flow Meter
Product Overview

Safety Electromagnetic Flow Meter 20mA with PTFE/PFA/F46 Liner Material for DN200-DN400 pipe sizes. Designed for reliable flow measurement in industrial applications.

Common Problems and Solutions
  1. Flow Reading Fluctuates/Jumps (Most Common)
    Causes: Air bubbles in the pipe, insufficient pipe filling, poor grounding, electromagnetic interference
    • Air removal: Install at the low point of the pipeline or add an exhaust valve upstream
    • Full pipe: Install horizontally with electrodes on the side to avoid air accumulation at the top; install vertically with fluid flowing upward
    • Grounding: Use a dedicated ground wire with resistance <10Ω; install grounding rings for plastic/insulated pipes
    • Anti-interference: Route signal cables away from power cables and ground the shielding layer at one end only
  2. No Flow Reading/Zero Display
    Causes: Empty pipe, reversed wiring, excitation/electrode failure, incorrect parameters
    • Ensure the pipeline is fully filled with no negative pressure
    • Check for reversed excitation and signal wires
    • Verify parameters such as meter diameter, measuring range, and units
    • Measure excitation coil resistance (normal: 80-150Ω)
  3. Inaccurate Measurement (Over/Under Reading)
    Causes: Electrode fouling, damaged liner, insufficient straight pipe length, zero drift
    • Clean electrodes: Use a soft brush or dilute hydrochloric acid to remove insulating deposits
    • Inspect liner: Check for wear, bulges, or cracks
    • Straight pipe requirements: Upstream ≥10D, downstream ≥5D (D = pipe diameter)
    • Zero calibration: Perform zero calibration when the pipe is full and static
  4. Zero Drift/Negative Reading with Flow
    Causes: Poor grounding, contaminated electrodes, low medium conductivity, interference
    • Re-establish reliable grounding to ensure equipotential connection
    • Clean electrodes and check insulation
    • Confirm medium conductivity >5μS/cm
    • Keep away from strong interference sources such as inverters and motors
Routine Maintenance (Preventive Measures)
  • Clean electrodes regularly to prevent fouling coverage
  • Maintain full pipe condition with no air bubbles or negative pressure
  • Ensure reliable grounding, separate from motor/pipe grounding
  • Route signal and power cables separately
  • Perform zero calibration regularly (every 3-6 months)
Safety Electromagnetic Flow Meter installation and components diagram

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Nanjing Inste Automation Co., Ltd.
Location East Mozhou Road , Nanjing ,Jiangsu , China
Contact Person Qi

Request A Quote

Please check your email address.
Your message must be at least 20 characters.