UL2517 5C×24AWG Robot Wire And Cable With SR-PVC Insulation / PVC Jacket
UL2517 5C×24AWG Tinned Copper Stranded Robot Cable with SR-PVC Insulation and PVC Jacket
| 5C×24AWG(40/0.08T)+WS | |||||
| CONDUCTOR | Material | Tinned copper stranded | |||
| Size | 40/0.08±0.008mm | ||||
| O.D.(Ref) | 0.58mm | ||||
| INSULATION | Material | SR-PVC | |||
| Min.average thickness | 0.23mm | ||||
| Min.thickness at any point | 0.18mm | ||||
| O.D. | 1.05±0.05mm | ||||
| CABLING | Filler | Cotton | |||
| Material | Non-woven-1 | ||||
| Construction | 5C×24AWG(40/0.08T)+W | ||||
| SPIRAL | Material | Tinned copper | |||
| Size | 0.10mm , 90% min. | ||||
| WRAP | Material | Non-woven-2 | |||
| JACKET | Material | PVC | |||
| Min.average thickness | 0.76mm | ||||
| Min.thickness at any point | 0.61mm | ||||
| O.D. | 5.00±0.20mm | ||||
Application:For internal wires of industrial control equipment and robot manipulators
This product is suitable for high speed drag chain, bending and high strength applications such as miniaturized linear motors.
Electric Performance:
Rated Temperature:-40~105℃
Voltage rating:300V
Max.conductor DC resistance(20℃):94.2Ω/km
Dielectric Strength AC:2.0kV/1min
Mechanical Performance:
Tensile strength:≥10.3MPa
Elongation:≥100%
Aged condition:136±1℃×168h
Percent of original tensile strength:≥70%
Percent of original elongation:≥65%
Chain test:bending radius:50mm,60times/min.,travel 500mm,5millions cycles min.