Custom ETD44 High Power High Frequency Transformer With 100 Watts Power Output And CE FCC
Price:
$8.5-11.8/pieces
MOQ:
1K
Delivery Time:
7-14 work days (Negotiable)
Brand:
CHIPSEN
Product Description
Customizable ETD44 High Frequency Transformer with 100 Watts Power Output and CE, FCC Certification
The ETD44 High Frequency Transformer is a customizable ferrite magnetic component designed for switch-mode power supplies, isolated control power, auxiliary power conversion, and high-frequency energy transfer. Its ETD44 core platform provides a practical balance among power capability, winding space, thermal performance, insulation design, and PCB installation.
Industry Applications & Specifications
| Industry | Typical Application | Typical Power Inquiry | Typical Switching Frequency | Key Parameters |
|---|---|---|---|---|
| Industrial Automation and PLC | PLC control power, HMI, I/O modules, industrial gateways and auxiliary power supplies | 80 to 250 W | 50 to 150 kHz | Primary inductance, turns ratio, leakage inductance, DCR, regulation, isolation and temperature rise |
| Solar Inverter and Energy Storage | Control board, gate driver, communication, BMS and isolated auxiliary power | 100 to 300 W | 50 to 150 kHz | Core loss, copper loss, flux density, saturation margin, leakage inductance, capacitance and efficiency |
| EV Charger and Power Electronics | Charging controller, communication module, gate driver and auxiliary power conversion | 100 to 300 W | 70 to 150 kHz | Turns ratio, peak current, saturation margin, leakage inductance, interwinding capacitance and DCR |
| Telecom and Network Equipment | 48V bus converter, communication equipment and isolated board power | 100 to 300 W | 80 to 250 kHz | Low DCR, controlled leakage inductance, magnetizing inductance, current density and conversion efficiency |
| Medical Equipment | Monitoring, diagnostic, treatment and isolated auxiliary power equipment | 100 to 250 W | 50 to 150 kHz | Magnetizing inductance, turns ratio, leakage inductance, DCR, capacitance and thermal margin |
All electrical parameters can be customized according to the customer's converter and end-product requirements.
Product Construction
| Construction Item | Standard Reference or Available Option |
|---|---|
| Core Platform | ETD44 ferrite core |
| Mounting Style | Horizontal through-hole mounting |
| Pin Configuration | Standard reference 9 plus 9 pins |
| Core Material | Application-specific ferrite material |
| Insulation System | Functional, basic, supplementary, double or reinforced insulation |
| Mechanical Protection | Varnish impregnation, vacuum impregnation, adhesive reinforcement or potting |
Key Characteristics
- High Efficiency: Optimized core material, turns count, conductor size and winding arrangement reduce core loss and copper loss
- Low Winding Resistance: Low-DCR winding options available using multi-strand wire, Litz wire or foil
- Controlled Leakage Inductance: Can be minimized or intentionally controlled according to converter topology
- Low Noise Construction: Adjustable winding tension, core assembly and mechanical fixation reduce audible noise
- Multiple Output Options: Supports single-output, multiple-output, center-tapped and auxiliary winding configurations
- Flexible Insulation Design: Basic, reinforced and customer-specific insulation constructions available
Applications
- Industrial automation control power supplies
- PLC, HMI and I/O module power
- Solar inverter auxiliary power
- Energy storage system control power
- EV charging equipment
- Telecom and network equipment
- UPS and data center equipment
- Medical equipment power supplies
- Industrial LED drivers
- Robotics equipment
Frequently Asked Questions
Q1: Is ETD44 a fixed power transformer model?
No. ETD44 defines the ferrite core and mechanical platform. Actual power capability depends on topology, input voltage, switching frequency, duty cycle, output current, flux density, thermal conditions, insulation construction and allowable temperature rise.
Q2: What information is required for quotation?
Please provide input-voltage range, converter topology, switching frequency, output voltages, output currents, continuous and peak power, duty cycle, primary inductance, isolation voltage, operating temperature, size limits, pinout and applicable safety requirements.
Q3: Can Chipsen customize the input and output voltages?
Yes. The turns ratio, wire size, winding arrangement and insulation system can be designed for the required input range and single or multiple output rails.
Q4: What is the MOQ?
The standard MOQ is 100 pieces. Prototype and production quantities can be discussed according to material availability and project requirements.
Q5: How long does quotation and sample production take?
Quotation target is within three days after complete technical requirements are received. Sample production can be targeted within seven days after specification, materials and construction are confirmed.
Why Choose Chipsen
- Application-Specific Customization: Developed around your actual circuit requirements
- OEM and ODM Support: Complete customization of electrical and mechanical specifications
- Engineering Collaboration: Technical review covering topology, frequency, insulation, thermal performance and PCB installation
- Flexible Prototype Support: Standard MOQ starts from 100 pieces
- Responsive Project Handling: Quick quotation and sample production timelines
- Warranty Support: Standard 5-year warranty, with extended options available