JFP 400kW 500kVA Open Type Volvo Diesel Genset

This 400kW/500kVA open-frame diesel generator set is powered by genuine Sweden VOLVO PENTA TAD1346GE 6-cylinder inline turbocharged intercooled water-cooled diesel engine. Matched with high-efficiency 100% copper brushless alternator. It supports dual-frequency 50Hz/60Hz to satisfy different national grid standards.

Product Overview

Adopts heavy-duty open-frame base frame for excellent heat dissipation and easy access for inspection and overhaul. 24V DC reliable electric starting system is equipped. Suitable for prime power or emergency standby power for large factories, mining sites, hospitals, commercial complexes and infrastructure projects. ISO & CE certificates are available for international tender and customs clearance.

Main Features
  • Prime power 400kW/500kVA, standby power 440kW/550kVA; genuine Volvo Penta TAD1346GE engine, 4-stroke inline 6-cylinder, turbocharged & air-to-air intercooled, electronic fuel injection EMS2.4 control, low fuel consumption, outstanding heavy-load continuous performance
  • Heavy-duty open-type steel base chassis, good heat-dissipation performance, convenient for field installation, inspection, filter replacement and maintenance
  • 100% copper brushless alternator, H-class insulation grade, IP23 protection grade, built-in AVR automatic voltage regulation, low temperature-rise, stable voltage output under fluctuating industrial loads
  • 3-phase 4-wire output, power factor 0.8 lagging; dual-frequency 50Hz/60Hz optional; rated voltage 400V,480V customizable
  • Rotational speed: 1500RPM for 50Hz, 1800RPM for 60Hz
  • 24V DC electric starting system with maintenance-free battery and battery charger
  • Industrial digital controller, real-time monitor voltage, current, frequency, oil pressure, coolant temperature, exhaust temperature and accumulated running hours
  • Full-range multi-protection: over-voltage, under-voltage, over-current, short-circuit, overspeed, low oil pressure, high-temperature alarm & automatic shutdown
  • Heavy-duty anti-vibration rubber mounts to reduce vibration transmission
  • Optional accessories: ATS auto-transfer switch, silent canopy, container housing, mobile trailer, remote monitoring module, multi-genset parallel cabinet
  • Certificates: ISO, CE optional for import and international bidding projects
Technical Specifications
Item Parameter
Prime Power 400kW / 500kVA
Standby Power 440kW / 550kVA
Engine Brand & Model Genuine VOLVO PENTA TAD1346GE, 6-cylinder inline, turbocharged intercooled
Frequency 50Hz / 60Hz Optional
Rotational Speed 1500RPM(50Hz) / 1800RPM(60Hz)
Cooling Method Water-Cooled
Rated Voltage 400V / 480V customizable
Phase & Wire 3 Phase 4 Wire
Power Factor 0.8 Lagging
Structure Open-Frame Genset
Starting Mode 24V DC Electric Start with battery charger
Alternator 100% Copper Brushless Alternator, H-Class Insulation, IP23 with AVR
Vibration Damping Heavy-duty anti-vibration rubber mounts
Control System Intelligent digital controller with full-range alarm & shutdown protection
Certificates ISO, CE optional
Application Large factory, mining site, hospital, commercial complex prime & emergency standby power
Optional ATS, silent canopy, container, mobile trailer, remote monitoring, parallel cabinet
Competitive Advantages
  • Original Volvo Penta TAD1346GE Swedish industrial engine, mature electronic injection technology, global spare-parts supply network, reliable long-time heavy-load operation
  • Open-frame design delivers excellent heat dissipation, simple inspection and low-cost on-site overhaul
  • Pure-copper brushless alternator ensures high generating efficiency, low temperature-rise and stable output under variable industrial loads
  • Dual-frequency configuration fits multiple-country grid standards, flexible voltage customization
  • Comprehensive alarm and shutdown protection effectively protects genset against abnormal-condition damage
  • Multiple optional configurations available; ISO & CE support global import customs-clearance and tender-project requirements
Application Scenarios

Large-scale manufacturing factories, mining sites, hospitals, commercial complexes, municipal infrastructure projects, providing prime power and emergency standby power for critical industrial and commercial equipment.

Product Gallery

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Nanjing Joyful Power Equipment Co., Ltd
Location No.20 Jiangjia Industrial Park, Gulou District, Nanjing, Jiangsu, China
Contact Person Alice

Request A Quote

Please check your email address.
Your message must be at least 20 characters.