HOOYA USB-310M-B-SU
Price:
Negotiable
MOQ:
550
Delivery Time:
5-6 weeks
Brand:
USB-310M-B-SU
Product Description
Product Overview
This document outlines the electrical and environmental performance specifications for the HS45E product from HAOYU (HONG KONG) LIMITED, adhering to various EIA and MIL-STD test methods.
Brand HAOYU (HONG KONG) LIMITED
Part Number SPEC-USB-001
| Item | Description | Test Methods | Test Specification |
|---|---|---|---|
| 7.1 | Insulation Resistance | EIA 364-21C | 100M minimum (unmated) between adjacent contacts and contacts and shell/ground. Apply 100Volts DC. |
| 7.2 | Low Level Contact Resistance | EIA 364-23b | 40m (Max) initial for VBUS and GND contacts; 10m (Max) initial for all other contacts. Delta 10m (Max) after test. 20mV Max. open circuit at 100mA. |
| 7.3 | Dielectric Withstanding Voltage | EIA 364-20 | There shall be no breakdown when subjected to 100VAC (RMS) for 1 minute between adjacent terminals. |
| 7.4 | Contact Current Rating | EIA364-70 | 5.0A applied collectively to VBUS pins, 1.25A to VCONN pin, and 0.25A to other contacts. Temperature rise shall not exceed 30C. |
| 3.x | Durability | EIA 364-09 | 10000 cycles. Must meet contact resistance (delta 10m Max), insertion force (5N-20N), extraction force (8N-20N), and visual inspection criteria. |
| 3.x | Cable Flexing | EIA 364-41 | 100 cycles in 2 planes at 120 degrees. No discontinuity over 1 microsecond or physical damage. |
| 3.x | Cable Pull-Out | EIA-364-38 | 40N steady state axial load for 1 minute. No discontinuity or physical damage. |
| 3.x | 4-axes continuity test | EIA364-18 | 8N tensile force for 10 seconds in 0, 90, 180, 270 directions. No discontinuity > 1s or physical damage. |
| 8.1 | Temperature Life | EIA 364-17 | 105C without applied voltage for 120 hours. Also 72 hours for preconditioning. Visual inspection required. |
| 8.2 | Thermal Shock | EIA 364-32 | 10 Cycles -55C and +85C. Mated connectors. No evidence of physical damage. |
| 8.3 | Salt Spray | MIL-STD-202F, Method 101D, Condition B | 48 hours at 35C with 5% Salt-solution. Shall meet visual requirements and show no physical damage. |
| 8.4 | Humidity | EIA 364-31 | 90% RH @ 25C for 24 hours, then 95% RH @ 65C for 24 hours. Shall meet visual requirements and additional tests as specified. |
Similar Products
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Shenzhen ECER Network Technology Co., Ltd.
Location
Unit A2603, One Avenue (South Zone), Zhuoyue Meilin Center Plaza, No. 126 Zhongkang Road, Meidu Community, Meilin Subdistrict, Futian District, Shenzhen
Contact Person
Sales