Product Overview

This document outlines the specifications for a USB connector, detailing its electrical and environmental performance characteristics. It is designed for applications requiring reliable data transfer and power delivery.

Brand HAOYU (HONG KONG) LIMITED
Document Number SPEC-USB-001
Revision A
Item Description Test Methods Test Specification
7-1 Insulation Resistance Unmated EIA 364-21C 100M minimum (unmated) between adjacent contacts and contacts and shell ground. Apply 100 Volts DC.
7-2 Low Level Contact Resistance EIA 364-23b 40m(Max) initial for VBUS and GND contacts and all other contacts; delta 10m(Max) after test. 20mV Max. open circuit at 100mA Max.
7-3 Dielectric Withstanding Voltage EIA 364-20 There shall be no breakdown. Subjected to 100VAC (RMS) for 1 minute between adjacent terminals.
7-4 Contact Current Rating EIA364-70 5.0A collectively to VBUS pins, 1.25A to VCONN pin, and 0.25A to other contacts. Temperature rise shall not exceed 30 C at an ambient temperature of 25 C.
8-1 Temperature Life EIA 364-17 105C without applied voltage for 120 hours. 105C without applied voltage for 72 hours (preconditioning). Visual inspection, test sequences defined in EIA 364-1000.01.
8-2 Thermal Shock EIA 364-32 10 Cycles -55C and +85C. USB 3.0 connectors must be mated. No physical damage.
8-3 Salt Spray MIL-STD-202F, Method 101D, Test Condition B 48 hours at 35C with 5% Salt-solution concentration. Shall meet visual requirement, no physical damage. Shall meet requirements of additional tests as specified in test sequence in Section 5.
Cycle Test Durability EIA 364-09 Type C: 10000 cycles. Must meet: Contact resistance (40m > delta 10m Max), Insertion force (5N to 20N), Extraction force (8N to 20N), Visual inspection (no exposed base metal).
Cable Flexing Cable Flexing EIA 364-41 100 cycles in 2 planes at 120 degrees. Dimension x=3.7x cable diameter. No discontinuity over 1 microsecond. No physical damage.
Cable Pull-Out Cable Pull-Out EIA-364-38 40N steady state axial load for 1 minute. No discontinuity or physical damage.
4-axes continuity test 4-axes continuity test EIA364-18 8N tensile force for 10 seconds. Subject to 0, 90, 180, 270 direction. No discontinuity greater than 1s and no physical damage.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Shenzhen ECER Network Technology Co., Ltd.
Location Unit A2603, One Avenue (South Zone), Zhuoyue Meilin Center Plaza, No. 126 Zhongkang Road, Meidu Community, Meilin Subdistrict, Futian District, Shenzhen
Contact Person Sales

Request A Quote

Please check your email address.
Your message must be at least 20 characters.