Technical Specifications
| Item | Test Conditions | Performance Specification |
|---|---|---|
| RATING | ||
| Rated Voltage | 5 V | |
| Rated Current | 3 A | |
| Practical Temperature Range | Within -30C~80C | -30C~80C |
| Standard Atmospheric Conditions | (1) Temperature: 5C to 35C (2) Humidity: 45% to 85% (3) Pressure: 86Kpa to 106Kpa | |
| MECHANICAL | ||
| Connection Force | After connecting and disconnecting using standard plug gauge 3 times | 0.5~2.0Kgf |
| Disconnect Force | After connecting and disconnecting using standard plug gauge 3 times | 0.8~2.0Kgf |
| Terminal Strength | Static load of 0.1N/m (1kgf/cm) applied to the tip of the terminal for 1 min in any direction. No damage, looseness, or play. Electrical and mechanical characteristics shall be satisfied. | |
| ELECTRICAL | ||
| Contact Resistance | Measured at small current (100mA or less), 1000Hz | 40m MAX |
| Insulation Resistance | Apply DC 100V for 1 min between: (1) Body and conductor, (2) Non-contacting conductors, (3) Non-contacting conductors when plug is inserted. | 100M MIN |
| Dielectric Strength | Apply AC 100V rms (50~60Hz) for 1 min, trip current: 0.5mA between: (1) Body and conductor, (2) Non-contacting conductors, (3) Non-contacting conductors when plug is inserted. | Without damage to parts, arcing, or breakdown. |
| DURABILITY | ||
| Solderability Test | Top of terminals dipped 1mm in solder bath at 2505 for 50.5 seconds. | (1) Solder wetting time: 3 seconds (2) Soldering area: 75% |
| Resistance to Soldering Heat Test (Reflow) | Preheat: 180 for 120s. Peak temperature: 2605 within 20 seconds. | No deformation of case or excessive looseness of terminals. Electrical characteristics shall be satisfied. |
| Resistance to Soldering Heat Test (Soldering Iron) | Bit temperature 3305, application time 30.5 seconds. No excessive pressure on terminals. | No deformation of case or excessive looseness of terminals. Electrical characteristics shall be satisfied. |
| Humidity Test | Stored at 402 and 90% to 96% humidity for 96 hours, then maintained at standard atmospheric conditions for 1 hour. | No damage on appearance. Mechanical and electrical characteristics shall be satisfied. |
| Heat Test | Stored at 702 for 96 hours, then subjected to controlled recovery for 1 hour. | No damage on appearance. Mechanical and electrical characteristics shall be satisfied. |
| Cold Test | Stored at -253 for 96 hours, then subjected to controlled recovery for 1 hour. | No damage on appearance. Mechanical and electrical characteristics shall be satisfied. |
| Life Test (Without Load) | 5000 cycles of connection/disconnection at a speed of 10 to 25 cycles/min. | Contact Resistance: 0.1 Disconnection Force: 0.8 to 2.0N Mechanical and electrical characteristics shall be satisfied. |
| Life Test (With Load) | 5000 cycles of connection/disconnection at a speed of 10 to 20 cycles/min under rating condition (non-inductive load). | Contact Resistance: 0.1 Disconnection Force: 0.8 to 2.0N Mechanical and electrical characteristics shall be satisfied. |
| Temperature Cycling Test | 5 cycles of specified temperature profile (e.g., 8 hours at 70, then -20). Allowed to remain in room ambient for 30 minutes. | No deformation or cracks in molded part. Insertion & Extraction Force: 3 to 20N Contact Resistance: Max. 30m Insulation Resistance: Min. 100 M Dielectric Withstanding Voltage: 100VAC/min (between terminals) |
| Cold & Heat Shock Test | 5 cycles of specified temperature profile (e.g., 1 hour at 70, then -20). Allowed to remain in room ambient for 30 minutes. | No deformation or cracks in molded part. Insertion & Extraction Force: 3 to 25N Contact Resistance: Max. 30m Insulation Resistance: Min. 100 M Dielectric Withstanding Voltage: 500VAC/min (between terminals) |