Test Requirements and Methods

This section details the performance requirements and test methods for the product, ensuring quality and reliability across various parameters.

Visual Examination

All components shall be properly assembled and free of burrs, warps, scratches, broken chips, and other abnormalities. Comply with method EIA 364-18B. Visual, functional, and dimensional inspection complies with applicable specification and document.

Item Requirement Test Method
Low Level Contact Resistance 20m Max. Initial, 70m Max. Final EIA-364-21D
Insulation Resistance 500 M Min. Initial, 100 M Min. Final EIA-364-21D (100V DC for 1 minute)
Dielectric Withstanding No evidence of breakdown or flash burn. Current leakage: 0.50 mA Max. EIA-364-20D, Test Method B (200V AC 1 minute)
VSWR (Plug) 1.3 Max. at 0.1~3GHz, 1.5 Max. at 3~6GHz EIA-364-20D
VSWR (Receptacle) 1.3 Max. at 0.1~3GHz, 1.4 Max. at 3~6GHz EIA-364-20D
Item Requirement Test Method
Contact Resistance (Inner Contact) 20 m Max. Initial, 40 m Max. Final EIA-364-28E (100mA DC)
Contact Resistance (Ground Contact) 20 m Max. Initial, 40 m Max. Final EIA-364-28E (100mA DC)
Appearance (Vibration) Looseness, chipping, breakage, or other abnormality shall not occur. EIA-364-27B
Electrical Discontinuity (Vibration) No electrical discontinuity greater than 1 micro-sec. MIL-STD-202, Method 213, Condition B (735m/s)
Contact Resistance (Physical Shock) 20 m Max. Initial, 40 m Max. Final EIA-364-27B (11msec, half sinusoidal)
Appearance (Humidity) Looseness, chipping, breakage, or other abnormality shall not occur. EIA-364-27B
Contact Resistance (Humidity) 20 m Max. Initial, 40 m Max. Final EIA-364-27B (40C, 90~95% RH)
Item Requirement Test Method
Insulation Resistance (Temperature Life) 500 M Min. Initial, 100 M Min. Final EIA-364-17B
D.W. Voltage (Temperature Life) No creeping discharge, flashover, nor insulator breakdown. EIA-364-17B
Appearance (H2S Gas) No abnormality adversely affecting performance. EIA-364-17B
Contact Resistance (H2S Gas) 20 m Max. Initial, 40 m Max. Final EIA-364-17B (90C, 96 hours)
Contact Resistance (H2S Gas) 20 m Max. Initial, 40 m Max. Final EIA-364-17B (40C, 80% RH, 3+/-1ppm H2S, 96 hours)

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Shenzhen ECER Network Technology Co., Ltd.
Location Unit A2603, One Avenue (South Zone), Zhuoyue Meilin Center Plaza, No. 126 Zhongkang Road, Meidu Community, Meilin Subdistrict, Futian District, Shenzhen
Contact Person Sales

Request A Quote

Please check your email address.
Your message must be at least 20 characters.