Surge Protection Device SPD
275VAC Power Surge Protection Device , Class 1 Surge Protection EN 61643-11
60kA Power Surge Protection Device, 275VAC Class I Surge Protector ,Type 1 SPD OBV10-I-15 Surge protectors OBV10-I-15 meet the type 1 requirement class according to IEC 61643-11. These devices protect low-voltage consumer systems from overvoltages of all types and are available in single-pole to four-pole versions.The voltage-limiting,high-performance spark gaps provide several benefits.A short response time, a low protection level and high current leakage capability with
TT Connection Power Surge Protection Device Response Time Less Than 25ns
60KA 100KA Power Surge Protection Device With Short Response Time OBV10-I-15 Surge protectors OBV10-I-15 meet the type 1 requirement class according to IEC 61643-11. These devices protect low-voltage consumer systems from overvoltages of all types and are available in single-pole to four-pole versions.The voltage-limiting,high-performance spark gaps provide several benefits.A short response time, a low protection level and high current leakage capability with long service
Industrial Power Surge Protection Device TT Connection 48V DC
Easy Installation Power Surge Protection Device For Industrial AutomationThe DC surge protector can be called a surge protector, also known as a lightning protector. It is a very commonly used electronic component. Its applicable current and voltage environment is DC 5V~1500VDC. In this kind of power supply system or communication system, DC wave Surge protectors can protect against transient overvoltage surges caused by direct or indirect lightning. They are widely used in
Un Nominal Working Voltage 1000V Surge Protector Breaker 35mm Slide Guide
unNominal working voltage (Un)1000V surge protector breaker Model and specification AM40-1000 Model AM40-1000 MainTechnicalData UnNominalworkingvoltage(Un) 1000V UcMaxcontinuousoperatingvoltage(Uc) 1100VAC Nominaldischargecurrent(kA) 20kA Maxdischargecurrent(kA) 40kA ProtectedMode + - PE,-- PE Protectionlevel(Up) 3.7kV Recommendmaxbackupfuse 63A(gL/gG) Responsetime ≤25ns Work/Faultindication Localindicatewindow: Green=SPDOK|White=SPDFailure Module 3 MechanicalSpecification
Outdoor Building Floor Surge Protection Device SPD Low Voltage 200 / 380VAC
outdoor input in the building and each floor Low voltage(200/380VAC) industrial SPDModel and specification AM40AModelAM40AMainTechnicalData UnNominalworkingvoltage(Un)230/400VUcMaxcontinuousoperatingvoltage(Uc)385VAC OperatingFrequency48-62HzNominaldischargecurrent(kA)20kAMaxdischargecurrent(kA)40kAProtectedModeL1,L2,L3,N-PE(4P)Protectionlevel(Up)1.8kVRecommendmaxbackupfuse63A(gL/gG)Responsetime≤25nsWork/FaultindicationLocalindicatewindow:Green=SPDOK|White=SPDFailureModule4Mec
I25X 420V Series Surge Protector SPD Protect Affected By Level 1 Lightning
II20X 375V series surge protectors protect against surges affected by indirect lightning and direct lightning The main technical parametersModel and specification U1-II20XUc(VAC)Maxi continuous operating voltage275, 385,420,440 VacUp(kV)Voltage protective level2.5kV(8/20μs)Imax(kA)Maxi discharging current50kA(8/20μs)In(kA)Nominal discharging current25kAresponse time≤25nsSignal deterioration indication off-work;on-replaceHousing Material Red thermoplastic materialHousing self
II40X 385V Series Surge Protector SPD Red Thermoplastic Material Housing
II20X 375V series surge protectors protect against surges affected by indirect lightning and direct lightning The main technical parameters Model and specification U1-II20X Uc(VAC)Maxi continuous operating voltage 1000,750,420,385,320,275,175,48Vac Up(kV)Voltage protective level 3.5, 3.0, 1.8, 1.5, 1.5,1.5, 1.3, 0.6 kV (8/20μs)Imax(kA)Maxi discharging current 400kA (8/20μs)In(kA)Nominal discharging current 20kA response time ≤25ns Signal deterioration indication off-work;on
Secondary Power Surge Protector SPD 60kA With Fast Response Time
120k secondary surge protector SPD OBV-I25: Rated voltage(VDC) 240/415Vac Iimp(impulse discharge current for class I test) 30KA In(nominal discharge current for class II test) 60kA Up(voltage protection level) ≤1.5kv response time ≤25ns Signal deterioration indication off-work;on-replace Housing Material Red thermoplastic material Housing self-extinguishing class UL94_V0 Temperature range -40℃~+80℃ humidity range 5%~95% Elevational ≤3000m Method of connecting wire multiple
Class 1 Save Space Power Surge Protector SPD 15kA Only 27mm Width
1+2 class 100kA surge protector SPD OBV-I25: Rated voltage(VDC) 240/415Vac Iimp(impulse discharge current for class I test) 15KA In(nominal discharge current for class II test) 15kA Up(voltage protection level) ≤1.5kv response time ≤100ns Signal deterioration indication off-work;on-replace Housing Material Red thermoplastic material Housing self-extinguishing class UL94_V0 Temperature range -40℃~+80℃ humidity range 5%~95% Elevational ≤3000m Method of connecting wire multiple
Integrated 1 + 2 Class Surge Protection Device SPD 20kA For 240 / 415Vac TN
1+2 class 100kA surge protector SPD OBV-I25: Rated voltage(VDC) 240/415Vac Iimp(impulse discharge current for class I test) 20KA In(nominal discharge current for class II test) 20kA Up(voltage protection level) ≤1.5kv response time ≤100ns Signal deterioration indication off-work;on-replace Housing Material Red thermoplastic material Housing self-extinguishing class UL94_V0 Temperature range -40℃~+80℃ humidity range 5%~95% Elevational ≤3000m Method of connecting wire multiple
Multiple Connecting Wire Surge Protector SPD 1 + 2 Class 50kA
1+2 class 100kA surge protector SPD OBV-I25: Rated voltage(VDC) 240/415Vac Iimp(impulse discharge current for class I test) 500KA In(nominal discharge current for class II test) 500kA Up(voltage protection level) ≤1.5kv response time ≤100ns Signal deterioration indication off-work;on-replace Housing Material Red thermoplastic material Housing self-extinguishing class UL94_V0 Temperature range -40℃~+80℃ humidity range 5%~95% Elevational ≤3000m Method of connecting wire
Sealed Metal Air Gap 100kA Surge Protector SPD With IEC And GB Standards
1+2 class 100kA surge protector SPD OBV-I25: Rated voltage(VDC) 230/400Vac Iimp(impulse discharge current for class I test) 100KA In(nominal discharge current for class II test) 100kA Up(voltage protection level) ≤1.5kv response time ≤100ns Signal deterioration indication off-work;on-replace Housing Material Red thermoplastic material Housing self-extinguishing class UL94_V0 Temperature range -40℃~+80℃ humidity range 5%~95% Elevational ≤3000m Method of connecting wire
H2-20 40 60 80 Series Photovoltaic Surge Protective Device SPD With PBT Shell
H2-20 40 60 80 series photovoltaic surge protective device SPD Model and specification H2-80H2-60H2-20H2-40 Rated voltage of Un(~V) 275V 385V 420V 275V 385V 420V 275V 385V 420V 275V 385V 420V Maximum continuous operating voltage Uc(~V 275V 385V 420V 275V 385V 420V 275V 385V 420V 275V 385V 420V (~kVVoltage protection level of Up(~ kV) 1.2kV 1.8kV 1.9kV 1.4kV 2.0kV 2.1 kV 1.4kV 2.2kV 2.3kV1.6kV 2.4kV 2.5kV In(8/20 us)(kA)Nominal discharge currant In(8/20 us)(kA) 4.0303E+23 Imax
IP20 Din Rail 80KA Surge Protection Device SPD Type 1+2
Din rail 80KA Surge Protection device Type 1+2 with lightning protection class 3+4 Technical Parameters Model: Maximum continuous voltage AC Uc V 275/320/385/440 SPD to EN 61643-11 Type 1+2 SPD to IEC 61643-1 class I+II Lightning impulse current (10/350µs) Iimp kA 15-25 Nominal discharge current (8/20µs) In kA 40-80 Maximum discharge current (8/20µs) Imax kA 80-160 Voltage protection level Up kV < 1,5/1,8/2,0/2,2 Response time tA ns < 25 Maximum back-up fuse A 125 Temperature
2P Class II Surge Arrester 275V For HVAC Applications
Class II Surge Arrester 275V with narrow size 18mm 2P for power system Feature&Benefits - Easy installation or retrofit - Din-rail mountable - Fail-safe /self-protected designRemote indicator (optional) with 3pin NO/NC contact - IP20 finger-safe design Visual indicator - Small foot print Application ● AC/DC distribution ● Power supplies ● Industrial automation ● Telecommunications ● Motor controls systems ● PLC applications ● Power transfer equipment ● HVAC applications ● AC
385V Type 2 Surge Protector With Thermoplastic Housing
Type 2 Surge Protector for house use lower voltage 385V Uc(maximum continuous operating voltage) 385Ucpv Imax(maximum discharge current) 40kA In(nominal discharge current for class II test) 20kA Up(voltage protection level) ≤2.0kv Combination 1P,2P,3P,4P response time ≤25ns Signal deterioration indication Red: replace Green:ok Housing Material thermoplastic material Housing self-extinguishing class UL94_V0 Temperature range -40℃~+80℃ humidity range 5%RH~95%RH Elevational
4P 385V 100KA Surge Protection Device SPD For Lower Voltage Power System
4P 385V 100kA Surge Protection Device SPD For Lower Voltage Power System OBV-II100-3 data Uc(maximum continuous operating voltage) 385V Imax(maximum discharge current) 10kA In(nominal discharge current for class II test) 20kA Up(voltage protection level) ≤2.5kv response time ≤25ns Signal deterioration indication red: need replace green: work Housing Material Flame retardant plastic Housing self-extinguishing class UL94_V0 Temperature range -40℃~+85℃ humidity range ≤95%
Home Use Class III IP20 1500V 3P 40KA Surge Protection Device
Class III IP20 1500V 3P 40kA Surge Protection Device for house use Uc(maximum continuous operating voltage) 1500Ucpv Imax(maximum discharge current) 40kA In(nominal discharge current for class II test) 20kA Up(voltage protection level) ≤2.0kv Combination 3P response time ≤25ns Signal deterioration indication Red: replace Green:ok Housing Material thermoplastic material Housing self-extinguishing class UL94_V0 Temperature range -40℃~+80℃ humidity range 5%RH~95%RH Elevational
4P 275V 20KA Surge Protection Device For Power System
4P Lower Voltage 275V 20kA Surge Protection Device SPD For Power System OBV-II20 data Uc(maximum continuous operating voltage) 275V Imax(maximum discharge current) 10kA In(nominal discharge current for class II test) 20kA Up(voltage protection level) ≤1.5kv response time ≤25ns Signal deterioration indication red: need replace green: work Housing Material Flame retardant plastic Housing self-extinguishing class UL94_V0 Temperature range -40℃~+85℃ humidity range ≤95% Elevationa
25ns Response 120kA Surge Protection Device For Type 1+2
25ns Response 120kA Surge Protection Device For Type 1 And Type 2 OBV12.5/120 data: Uc(maximum continuous operating voltage) 320V Iimp(impulse discharge current for class I test) 12.5kA Imax(maximum discharge current) 120kA In(nominal discharge current for class II test) 80kA Up(voltage protection level) ≤2.3kv Power System L-N/E, single phase response time ≤25ns Housing Material thermoplastic material Housing self-extinguishing class UL94_V0 Temperature range -40℃~+70℃