Heat Recovery Unit
Residential Air Conditioning Heat Recovery Unit Screw Water Cooled Chiller 90 -170 Tons
Heat recovery unit screw type water cooled chiller 90 -170 tons More Energy Saving An EKSC water (ground) source heat pump system uses heat exchangers to directly exchange heat with a geothermal energy source to reduce the consumption of fossil resources. It is basically immune to ambient environment changes, efficient, and energy saving. The operation efficiency around the year is 40-60% higher than traditional central air conditioning systems. Environment Friendly When
Packaged Heat Recovery Unit Scroll Ground Water Heat Pump Chiller
Specifications Basic modules EKWD021CRGR/GV EKWD032CRGR/GV EKWD043CRGR/GV Underground water mode Nominal Cooling Capacity kW 77 115 154 Nominal Heating Capacity kW 84 128 169 Total Power of Nominal Cooling Capacity kW 13.0 20.0 27.0 Total Power of Nominal Heating Capacity kW 17.2 27.0 35.6 Water flow Application side m/h 13.2 19.8 26.4 Heat source side m/h 7.0 10.6 14.1 Heat Recovery Mode Nominal Cooling
Energy Saving Scroll Heat Recovery Unit 8 Ton Air Conditioner Heat Pump
8 tons Total Heat Recovery Air-cooled Heat Pump Unit with max dosmesitc hot water temperature 60 C Unit Features Air-cooled heat pump units of the full heat recovery model feature a brand new European design and R&D technology. They are a perfect combination of air-cooled chilled/hot water unit and air source heat pump hot water unit. Besides providing cooling in summer and heating in winter for buildings, units of this series can also provide hot water of 45C - 60C.
Household R410A Total Heat Recovery Air Cooled Heat Pump Unit With 65 C Hot Water
Household R410A Total Heat Recovery Air-Cooled Heat Pump Unit with 65 C hot water Featuring leading-edge manufacturing and master designs from Italy,the unit is a perfect combination of aesthetics and technology. TheR410A environment-friendly refrigerant is used to providing heating, cooling, and "free" hot water up to 65C around the clock. Compared with traditional household central air conditioning systems plus hot water systems, units of this series can save energy up to
R407C Air Cooled Screw Chiller Heat Recovery Units 85 - 235 Tons
Screw air cooled water chiller total heat recovery unit 85 - 235 tons Specifications Model EKAS 085 EKAS 095 EKAS 115 EKAS 125 EKAS 140 EKAS 150 EKAS 165 EKAS 180 EKAS 190 EKAS 200 EKAS 210 EKAS 225 EKAS 235 Nominal cooling capacity kW 284.1 328.3 388.0 410.3 473.7 509.4 557.3 601.0 636.4 683.3 728.2 797.2 819.9 USRT 80.8 93.3 110.3 116.7 134.7 144.8 158.5 170.9 180.9 194.3 207.1 226.7 233.1 ×104 kcal/h 24.4 28.2 33.4 35.3 40.7 43.8 47.9 51.7 54.7 58.8 62.6 68.6 70.5
R407C Screw Air Cooled Heat Recovery Unit With Spiral Axial Fan 85 - 470 Tons
R407C Screw type air cooled (heat pump) partial heat recovery unit 85 - 470 tons Specifications Model EKAS 085 EKAS 095 EKAS 115 EKAS 125 EKAS 140 EKAS 150 EKAS 165 EKAS 180 Nominal cooling capacity kW 284.1 328.3 388.0 410.3 473.7 509.4 557.3 601.0 USRT 80.8 93.3 110.3 116.7 134.7 144.8 158.5 170.9 ×104kcal/h 24.4 28.2 33.4 35.3 40.7 43.8 47.9 51.7 Nominal heating capacity* kW 322.7 354.7 426.9 431.3 491.6 528.6 578.4 623.7 USRT 91.8 100.9 121.4 122.6 139.8 150.3 164.4 177
Commercial Heat Recovery Unit Ground Source Heat Pump Cooling / Heating Hot Water
Heat recovery unit modular ground source heat pump cooling heating hot water Specifications Basic modules EKWD021CRDR/DV EKWD032CRDR/DV EKWD043CRDR/DV Underground circulation mode Nominal Cooling Capacity kW 76 113 153 Nominal Heating Capacity kW 79 115 159 Total Power of Nominal Cooling Capacity kW 13 20.4 27.2 Total Power of Nominal Heating Capacity kW 16.8 26.0 34.3 Water flow Application side m/h 13.1 19.4 26.3 Heat source side m/h 15.3 22.9 31.0 Heat Recovery Mode
R410A Heat Recovery Unit Modular Water Source Heat Pump 74 KW 110KW 150KW
Specifications Basic modules EKWD021CRQR/QV EKWD032CRQR/QV EKWD043CRQR/QV Water Circulation Mode Nominal Cooling Capacity kW 74 110 150 Nominal Heating Capacity kW 89 148 200 Total Power of Nominal Cooling Capacity kW 14.0 22.3 30.0 Total Power of Nominal Heating Capacity kW 17.2 28.5 37.4 Water flow Application side m/h 12.7 18.9 25.8 Heat source side m/h 15.1 22.8 30.9 Heat Recovery Mode Nominal
Low Temperature Modular Heat Recovery Unit Air Source Heat Pump
Low-Temperature High Efficiency Total Heat Recovery Unit Modular Air-Cooled Heat Pump Specifications Model EKAC 210BRLHR EKAC 420BRLHR EKAC 360BRLHR EKAC 840BRLHR EKAC 1050BRLHR EKAC 1260BRLHR Air conditioning mode Nominal cooling capacity kW 58 116 174 232 290 348 Nominal heating capacity kW 63 126 189 252 315 378 Total power of nominal cooling capacity kW 16 32 48 64 80 96 Total power of nominal heating capacity kW 17 34 51 68 85 102 Water flow rate for nominal cooling
High Efficiency R22 Heat Recovery Unit Air Conditioning Chiller For Hotels / Hospitals
12.1 High Efficiency Total Heat Recovery Modular Air-cooled Chiller Specifications: Model EKAC 230BRSR EKAC 460BRSR EKAC 690BRSR EKAC 920BRSR EKAC 1150BRSR EKAC 1380BRSR Unit combination Master unit EKAC230BRSRM EKAC230BRSRM EKAC230BRSRM EKAC230BRSRM EKAC230BRSRM EKAC 230BRSRM slave unit -- EKAC230BRSRS 2EKAC230BRSRS 3EKAC230BRSRS 4EKAC230BRSRS 5EKAC 230BRSRS Air conditioning mode Nominal cooling capacity kW 65.5 131.0 196.5 262.0 327.5 393.0 Nominal heating capacity kW 69