Infant Incubator
X-Ray Hospital Medical Infant Incubator , Neonatal Incubator For Baby
SK-N106 X-Ray Hospital Medical Infant Incubator , Medical Equipment For Baby Specifications: ● Pre-warm mode control, manual mode control and baby mode control by micro-computer ● Set temperature and baby temperature can be displayed separately ● Horizon angle of heater head and inclination of the bassinet can be adjusted ● The panels around bassinet can be turned outward ● X-ray cassette under the bassinet ● APGAR timer ● Failure alarm indication ● RS232 connector Model SK
Hospital Medical Infant Incubator Hospital , Infant Transport Incubator
Sk-N202 Hospital Medical Infant Incubator , Medical Equipment Specifications: * Power supply: AC220V-230V/50Hz or AC110-120V/50-60Hz * Maximum Power Output: 75VA * Light source:LED * Peak spectrum of radiant light resource:465nm * The highest total irradiance for bilirubin on the effective surface area: ≥ 3.5mw/cm2 (SK-N202 mobile) ≥ 1.7mw/cm2 (SK-N202 fixed) * Uniformity of the total irradiance for bilirubin: > 0.4 * Wave length of blue light: 420-470nm * Lifetime of LED:
Advanced Portable Infant Incubator Temperature Control Infant Phototherapy Unit
Sk-N201 Hospital Medical Infant Incubator , Infant Phototherapy Unit Specifications: * Power supply: AC220V-230V/50Hz or AC110-120V/50-60Hz * Maximum Power Output: 150VA * Light source: blue fluorescent tube * Peak spectrum of radiant light resource: 436nm * The highest total irradiance for bilirubin on the effective surface area: ≥ 1.lmw/cm2 (SK-N201 mobile) ≥ 0.73mw/cm2 (SK-N201 fixed) * Uniformity of the total irradiance for bilirubin: > 0.4 * Wave length of blue light:
Electric Medical Infant Incubator / Newborn Baby Kept Incubator With CE
Sk-N101 Electric Medical Infant Incubator , Infant Radiant Warmer Specifications: * Power supply:AC220V-230V/50Hz or AC110-120V/50-60Hz Maximum power output:600VA * Mode of control:Pre-warm mode control, manual mode control and baby mode control by micro-computer Baby mode temperature control * Range:34.5-37.5℃ * Temperature sensor display range:5-65℃ * Accuracy of skin temperature sensor:±0.3℃ * Temperature uniformity of mattress:≤2℃ * Angle of warmer module:0,30,45for two
Hospital Medical Neonatal Transport Incubator Infant Radiant Warmer
Sk-N102 Electric Medical Infant Incubator , Infant Radiant Warmer Specifications: * Power supply: AC220V-230V/50Hz or AC110-120V/50-60Hz * Maximum Power Output:700VA * Mode of control: Pre-warm mode, manual mode and baby mode are controled by micro- computer * Baby mode temperature control range: 34.5-37.5℃ * Temperature sensor display range: 5℃ -65℃ * Accuracy of skin temperature sensor: ±0.3℃ * Temperature uniformity of mattress: ≤ 2℃ * Angle of warmer module:0,30,60for two
Hospital Nursery Equipment Infant Incubator / Radiant Warmer For Newborn
SK-N002 Electric Medical Infant Incubator For Newborn Baby Use Specifications: * Power supply: AC220V-230V/50Hz or AC110-120V/50-60Hz * Max Power Output: 850VA * Mode of control: Air mode control * Air temperature control range: 25℃ -37℃ (override mode: 37-39℃ ) * Temperature variability: ≤0.5℃ * Temperature uniformity: ≤0.8℃ (mattress is on the horizontal position) * Inclination of the bassinet: ±12. * Noise inside hood: ≤55dB(A) (Environment noise ≤45dB(A) * Optional: with