Refrigeration Solenoid Valve
Danfoss Type EVR 6 032F1209 Refrigeration Solenoid Valve 1/2''
Danfoss Type EVR 6 032F1209 Refrigeration Solenoid Valve 1/2' The shown is danfoss type EVR 6 solenoid valve, 1/2' (12mm) ODF solder port size, 2 way normally closed, 12V DC, 24V DC, 24V AC, 110V AC, 220V AC voltages (other voltages can be customized), ordering code: 032F1209, 032L1209. Refrigeration solenoid valves are typically used in industrial refrigeration and air conditioning systems to control refrigerant flow. At the heart of any solenoid valve is an electrically
Danfoss Type EVR 6 032F1212 Refrigeration Solenoid Valve 3/8''
Danfoss Type EVR 6 032F1212 Refrigeration Solenoid Valve 3/8' The shown is danfoss type EVR 6 solenoid valve, 3/8' (10mm) ODF solder port size, 2 way normally closed, 12V DC, 24V DC, 24V AC, 110V AC, 220V AC voltages (other voltages can be customized), ordering code: 032F1212, 032L1212. When you need to replace a refrigeration solenoid valve, BRANDO carries the right one for your system, plus the solenoid coil to match. Regulate your refrigerant with a thermostatic expansion
Danfoss Type EVR 3 032F1204 Refrigeration Solenoid Valve 3/8''
Danfoss Type EVR 3 032F1204 Refrigeration Solenoid Valve 3/8' The shown is danfoss type EVR 3 solenoid valve, 3/8' (10mm) ODF solder port size, 2 way normally closed, 12V DC, 24V DC, 24V AC, 110V AC, 220V AC voltages (other voltages can be customized), ordering code: 032F1204, 032F1208. Refrigeration solenoid valve: A solenoid valve is an electromechanical valve frequently used to control the flow of liquid or gas. Definitions. Solenoid valves are found in many applications
EVR 20 Series 7/8" ODF 032L1240 032L1254 Refrigeration Solenoid Valve
EVR 20 Series 7/8" ODF 032L1240 032L1254 Refrigeration Solenoid Valve Causes and troubleshooting methods: 1. When the solenoid directional valve coil is open, short-circuited or burned out, it cannot be attracted, causing the slider to not move. Should be replaced. The armature of the solenoid valve is stuck and cannot move, causing the slider to not move. The valve body can be opened for cleaning and adjustment. 2. The flow direction of the solenoid valve is reversed,
EVR 10 5/8'' ODF 032L1214 032L7149 Danfoss Type Refrigeration Valve
EVR 10 5/8' ODF 032L1214 032L7149 Danfoss Type Refrigeration Valve The shown is EVR 10 solenoid valve, 1/2' (12mm), 5/8' (16mm) ODF solder port size, 2 way normally closed, 24V DC, 110V AC, 220V AC, 230V AC voltages (other voltages can be customized), ordering code: 032F1217, 032F1218, 032F1214. 1. Refrigeration Solenoid Valve: * Danfoss Type: EVR 3, EVR 6, EVR 10, EVR 15, EVR 20, EVR 22, EVR 25, EVR 32, EVR 25, EVRA 25, EVRA 32, EVRA 40; * Castel Type: 1020/2, 1020/3, 1064/3
EVR 10 1/2'' Inch ODF 032L1217 032L1188 Refrigeration Solenoid Valve
EVR 10 1/2' Inch ODF 032L1217 032L1188 Refrigeration Solenoid Valve The shown is EVR 10 solenoid valve, 1/2' (12mm), 5/8' (16mm) ODF solder port size, 2 way normally closed, 24V DC, 110V AC, 220V AC, 230V AC voltages (other voltages can be customized), ordering code: 032F1217, 032F1218, 032F1214. 1. Refrigeration Solenoid Valve: * Danfoss Type: EVR 3, EVR 6, EVR 10, EVR 15, EVR 20, EVR 22, EVR 25, EVR 32, EVR 25, EVRA 25, EVRA 32, EVRA 40; * Castel Type: 1020/2, 1020/3, 1064
032L8072 EVR 6 Series 3/8'' Inch SAE Flare Refrigeration Solenoid Valve
032L8072 EVR 6 Series 3/8' Inch SAE Flare Refrigeration Solenoid Valve The shown is EVR 6 solenoid valve, 1/2' (12mm), 3/8' (10mm) SAE flare port size, 2 way normally closed, 24V DC, 110V AC, 220V AC, 230V AC voltages (other voltages can be customized), ordering code: 032F8072, 032F8079. 1. Refrigeration Solenoid Valve: * Danfoss Type: EVR 3, EVR 6, EVR 10, EVR 15, EVR 20, EVR 22, EVR 25, EVR 32, EVR 25, EVRA 25, EVRA 32, EVRA 40; * Castel Type: 1020/2, 1020/3, 1064/3, 1064/4
EVR 6 Series 1/2'' Inch 032L1209 032L7144 ODF Cooling Solenoid Valve
EVR 6 Series 1/2' Inch 032L1209 032L7144 ODF Cooling Solenoid Valve EVR Solenoid Valve Product Introduction: Our plunger solenoid valve are direct or servo operated solenoid valve for liquid, suction, and hot gas lines with fluorinated refrigerants. EVR plunger solenoid valve are supplied complete or as seprate components, i.e. valve body, coil and flanges, if required, can be ordered seprately. EVR solenoid valve features: 1, complete range of solenoid valve for refrigeratio
EVR 3 Series 3/8'' Inch 032F1204 Refrigeration Solenoid Valve
EVR 3 Series 3/8' Inch 032F1204 Refrigeration Solenoid Valve Technical Data: Type Current Type Connection Size Max. working pressure Kv valve [m3/h] Cv valve [gal/min] Coder No. [mm] [in.] [bar] [psi] EVR3 a.c./d.c. - 1/4 45.2 655 0.27 0.32 032F1206 a.c./d.c. - 3/8 45.2 655 0.27 0.32 032F1204 a.c./d.c. 6 - 45.2 655 0.27 0.32 032F1207 a.c./d.c. 10 - 45.2 655 0.27 0.32 032F1208 Dimension: Ice machine ice - making principle 1. Water enters into the storage tank automatically
1-1/8" ODS 1099/9 Castel Type Air Conditioner HM2 Solenoid Valve
1-1/8" ODS 1099/9 Castel Type Air Conditioner HM2 Solenoid Valve 1099/9S: 1-1/8' Inch ODS Connection Diaphragm Pilot Operated NC Refrigeration Solenoid Valve ODS Connection Without Coil. 1099/9A6: 1-1/8' Inch ODS Connection Diaphragm Pilot Operated NC Refrigeration Solenoid Valve ODS Connection With 220/230 VAC(A6) Coil. 1099/9A7: 1-1/8' Inch ODS Connection Diaphragm Pilot Operated NC Refrigeration Solenoid Valve ODS Connection With 240 VAC(A7) Coil. HF2 HF3 HM2 HM3 HM4 CM2
1098/7 7/8'' Inch ODF Solder HM2 Series Refrigeration Solenoid Valve
1098/7 7/8' Inch ODF Solder HM2 Series Refrigeration Solenoid Valve 1098/7S: 7/8' Inch ODS Connection Diaphragm Pilot Operated NC Refrigeration Solenoid Valve ODS Connection Without Coil. 1079/7A6: 7/8' Inch ODS Connection Diaphragm Pilot Operated NC Refrigeration Solenoid Valve ODS Connection With 220/230 VAC(A6) Coil. 1079/7A7: 7/8' Inch ODS Connection Diaphragm Pilot Operated NC Refrigeration Solenoid Valve ODS Connection With 240 VAC(A7) Coil. HF2 HF3 HM2 HM3 HM4 CM2 Coil
1090/6 3/4'' Inch SAE Flare Castel Type Refrigeration HM2 Solenoid Valve
1090/6 3/4' Inch SAE Flare Castel Type Refrigeration HM2 Solenoid Valve 1090/6S: 3/4' Inch SAE Connection Diaphragm Pilot Operated NC Refrigeration Solenoid Valve ODS Connection Without Coil. 1090/6A6: 3/4' Inch SAE Connection Diaphragm Pilot Operated NC Refrigeration Solenoid Valve ODS Connection With 220/230 VAC(A6) Coil. 1090/6A7: 3/4' Inch SAE Connection Diaphragm Pilot Operated NC Refrigeration Solenoid Valve ODS Connection With 240 VAC(A7) Coil. HF2 HF3 HM2 HM3 HM4 CM2
Castel Type 1078/4 1/2'' Inch ODS Connection HM2 Solenoid Valve
Castel Type 1078/4 1/2' Inch ODS Connection HM2 Solenoid Valve 1078/4S: 1/2' Inch ODS Connection Diaphragm Pilot Operated NC Refrigeration Solenoid Valve ODS Connection Without Coil. 1078/4A6: 1/2' Inch ODS Connection Diaphragm Pilot Operated NC Refrigeration Solenoid Valve ODS Connection With 220/230 VAC(A6) Coil. 1078/4A7: 1/2' Inch ODS Connection Diaphragm Pilot Operated NC Refrigeration Solenoid Valve ODS Connection With 240 VAC(A7) Coil. HF2 HF3 HM2 HM3 HM4 CM2 Coil can
1070/4 1/2'' Inch SAE Flare Castel Type Refrigeration Solenoid Valve
1070/4 1/2' Inch SAE Flare Castel Type Refrigeration Solenoid Valve 1070/4S: 1/2' Inch SAE Connection Diaphragm Pilot Operated NC Refrigeration Solenoid Valve ODS Connection Without Coil. 1070/4A6: 1/2' Inch SAE Connection Diaphragm Pilot Operated NC Refrigeration Solenoid Valve ODS Connection With 220/230 VAC(A6) Coil. 1070/4A7: 1/2' Inch SAE Connection Diaphragm Pilot Operated NC Refrigeration Solenoid Valve ODS Connection With 240 VAC(A7) Coil. HF2 HF3 HM2 HM3 HM4 CM2 Coil
1068/3 Diaphragm Pilot Operated ODS 3/8'' Cooling Solenoid Valve
1068/3 Diaphragm Pilot Operated ODS 3/8' Cooling Solenoid Valve 1068/3S: 3/8' Inch Diaphragm Pilot Operated NC Refrigeration Solenoid Valve ODS Connection Without Coil. 1068/3A6: 3/8' Inch Diaphragm Pilot Operated NC Refrigeration Solenoid Valve ODS Connection With 220/230 VAC(A6) Coil. 1068/3A7: 3/8' Inch Diaphragm Pilot Operated NC Refrigeration Solenoid Valve ODS Connection With 240 VAC(A7) Coil. HF2 HF3 HM2 HM3 HM4 CM2 Coil can be mounted on the valve. Castel type
1064/3 3/8'' Inch SAE Flare Castel Refrigeration Solenoid Valve
1064/3 3/8' Inch SAE Flare Castel Refrigeration Solenoid Valve 1064/3S: 3/8' Diaphragm Pilot Operated NC Refrigeration Solenoid Valve SAE Flare Connection Without Coil. 1064/3A6: 3/8' Diaphragm Pilot Operated NC Refrigeration Solenoid Valve SAE Flare Connection With 220/230 VAC(A6) Coil. 1064/3A7: 3/8' Diaphragm Pilot Operated NC Refrigeration Solenoid Valve SAE Flare Connection With 240 VAC(A7) Coil. HF2 HF3 HM2 HM3 HM4 CM2 Coil can be mounted on the valve. The shown is 1064
1020/2S 1/4'' Direct Acting SAE Flare NC Refrigeration Solenoid Valve
1020/2S 1/4' Direct Acting SAE Flare NC Refrigeration Solenoid Valve 1020/2S: 1/4' Direct Acting NC Refrigeration Solenoid Valve SAE Flare Connection Without Coil. 1020/2A6: 1/4' Direct Acting NC Refrigeration Solenoid Valve SAE Flare Connection With 220/230 VAC(A6) Coil. 1020/2A7: 1/4' Direct Acting NC Refrigeration Solenoid Valve SAE Flare Connection With 240 VAC(A7) Coil. HF2 HF3 HM2 HM3 HM4 CM2 Coil can be mounted on the valve. Technical Data: Operating Principles Model
EVR 6 3/8'' 032L1212 032L5219 Danfoss Type Refrigeration Solenoid Valve
EVR 6 3/8' 032L1212 032L5219 Danfoss Type Refrigeration Solenoid Valve Technical Data: Type Current Type Connection Size Max. working pressure Kv valve [m3/h] Cv valve [gal/min] Coder No. [mm] [in.] [bar] [psi] EVR6 a.c./d.c. - 1/2 45.2 655 0.80 0.92 032F1209 a.c./d.c. - 3/8 45.2 655 0.80 0.92 032F1212 a.c./d.c. 10 - 45.2 655 0.80 0.92 032F1213 a.c./d.c. 12 - 45.2 655 0.80 0.92 032F1236 Dimension: Pilot-operated solenoid valve operation In a pilot-operated solenoid valve, the
EVR 6 1/2'' 032L1209 032L7144 Danfoss Type Solenoid Valve
EVR 6 1/2' 032L1209 032L7144 Danfoss Type Solenoid Valve Technical Data: Type Current Type Connection Size Max. working pressure Kv valve [m3/h] Cv valve [gal/min] Coder No. [mm] [in.] [bar] [psi] EVR6 a.c./d.c. - 1/2 45.2 655 0.80 0.92 032F1209 a.c./d.c. - 3/8 45.2 655 0.80 0.92 032F1212 a.c./d.c. 10 - 45.2 655 0.80 0.92 032F1213 a.c./d.c. 12 - 45.2 655 0.80 0.92 032F1236 Dimension: Solenoid valves play an important role within refrigeration and air conditioning systems,
EVR 15 NC 032F1225 7/8'' Danfoss Type Liquid Line Solenoid Valve 220V
EVR 15 NC 032F1225 7/8' Danfoss Type Liquid Line Solenoid Valve 220V EVR 15 refrigeration solenoid valve; 032F1225, 032L1225 ordering code; 7/8' port size; solder connection type. EVR is a direct or servo operated solenoid valve for liquid, suction, and hot gas lines with HCFC and HFC refrigerants. Product Features: 1. A Complete Range of Solenoid Valves for Refrigeration, Freezing and Air Conditioning Systems 2. AC and DC Coils are Interchangeable on All Valve Body Versions