Aerosol generator/dop PAOleak detection
AG-60 Aerosol Generator for HEPA Leak Detection 50-4725cfm 220V
Portable Laskin-Nozzle aerosol generator with 1-4 nozzles, producing 10-100ug/l concentration. Rugged stainless steel, dual-mode operation, and external air support for triple fog volume. Ideal for HEPA/ULPA filter testing in cleanrooms and HVAC systems.
HEPA Test Aerosol Generator TDA-5C 1500-65000 CFM 110-240V
TDA-5C aerosol generator for HEPA filter certification. Features digital temp control, 4-hour continuous operation, and 1500-65000 CFM airflow range. Supports PAO/DOP polydispersed aerosols with 110-240V power. Ideal for leak testing large filtration systems.
Aerosol Generator AG-60 for HEPA Leak Detection 220V 50Hz Cleanroom DOP PAO
Portable Laskin-Nozzle aerosol generator with 1-4 nozzles, 10-100ug/l concentration, and 50-4725cfm/min airflow. Rugged stainless steel, dual-mode operation, ideal for HEPA filter testing in cleanrooms, biosafety cabinets, and HVAC systems.
PAO-4 HEPA Filter Leak Detection Aerosol Concentrate 100% for Aerosol Generator Testing
PAO-4 aerosol concentrate is a non-toxic, odorless fluid for HEPA filter leak detection. With 100% concentration and FDA recommendation as a DOP substitute, it ensures accurate testing. Flash point 432°F, density 0.819, and water insoluble. Ideal for industrial and cleanroom applications.
HEPA Filter PAO Test Aerosol Generator AG60 220V AC 50-2000cfm
Compact AG60 aerosol generator for HEPA filter PAO leak detection. Features 220V AC power, 50-2000cfm airflow, built-in pump, and optional external compressed air. Supports PAO, DOP, and polydispersed aerosols. Ideal for clean rooms and operating rooms.
AG-60 Cold Aerosol Generator for HEPA Leak Detection PAO DOP 220V 50-2000 cfm
The AG-60 cold aerosol generator delivers precise HEPA leak detection using PAO or DOP reagents. Features a built-in air compressor, 220V AC power, and air flow range of 50-2000 cfm. Compatible with photometer 2i. Ideal for cleanrooms, labs, and HVAC systems. Customizable and ready to ship.
Portable Cold Aerosol Generator AG-60 for HEPA Leak Detection 4725cfm/min
The AG-60 portable cold aerosol generator features built-in Laskin nozzles and pump, delivering 10-100ug/l concentration at up to 4725cfm/min. Ideal for HEPA filter leak testing with PAO, DOP, or polydispersed aerosols. Supports 220V or optional gas power. Compact, reliable, and customizable for industrial use.
Portable Aerosol Generator AG-60 for HEPA PAO Leak Detection 50-2000 CFM
Compact stainless steel aerosol generator with built-in pump for HEPA filter PAO leak testing. Generates 10-100 ug/L aerosol at 50-2000 CFM. Features Laskin nozzles, pressure control, and optional external air. Ideal for cleanrooms and BSCs.
Cold Aerosol Generator AG-60 for PAO HEPA Leak Detection 220V 50-2000cfm
The AG-60 is a portable Laskin-Nozzle aerosol generator for PAO, DOP, and polydispersed aerosols. It delivers 10-100ug/l concentration at 50-2000cfm. Built with rugged stainless steel, it features a big filling port and optional external compressed air. Ideal for HEPA filter leak testing in cleanrooms and labs.
AG250 Portable Aerosol Generator 230V 0-250 L/h for HEPA Filter Detection Test
Compact stainless steel aerosol generator for clean room and HEPA filter testing. Features adjustable flow 0-250 L/h, 80 ml filling capacity, and binary nozzle for high particle generation. Easy handling, low maintenance, and 230V power supply. Made in Germany.
KM AG250 Portable Stainless Steel Aerosol Generator 250 L/h for HEPA Filter Detection Test
Compact AG250 aerosol generator for HEPA filter testing and clean room validation. Features adjustable flow meter (0-250 L/h), binary nozzle, and stainless steel housing. Compatible with DEHS, DOP, PAO. Made in Germany. Ideal for VDI 2083/DIN 1946 compliance.