Medical Test Equipment
ISO80369-20 Annex B and C Medical Liquid Leakage Tester
ISO80369-20 Annex B and C Medical Liquid Leakage Tester Standard ISO80369-20 Annex B and Annex C Precision Leakage Testing Solution Our state-of-the-art Pressure and Positive-Pressure Liquid Leakage Tester provides medical device manufacturers with precise liquid leakage testing according to ISO80369-20 Annex B and Annex C standards. Featuring an advanced control system, this high-performance tester delivers accurate, repeatable results for all pressure testing and positive
ISO 80369-20 Connector Assembly Device for Medical Testing
ISO 80369-20 Connector Assembly Device for Medical Testing Product Specifications Attribute Value Standard ISO80369-20 Annex B, Annex C, Annex D, Annex E, Annex G, Annex H Assembly Force 26.5N - 27.5N Assembly Torque 0.018N.m - 0.17N.m for lock connectors Product Description Our Connector Assembly Device for ISO 80369-20 is a precision-engineered tool designed to apply the required force and torque simultaneously when connecting a reference connector with a test sample. This
ISO 80369-7 Female Ring Gauge HRC58-62 Hardness Steel
ISO 80369-7 Female Ring Gauge For Male Luer Connector Testing Our female ring gauge is precision-engineered to verify the dimensional accuracy of male luer connectors as specified in ISO 80369-7. This essential quality control tool helps medical device manufacturers ensure their luer fittings meet international standards. Key Features Precision Machined - Manufactured to exacting tolerances for reliable testing Material Durability - Made from hardened stainless steel for long
ISO 80369-7-Figure C.6 Male Reference Connector For Testing Female Luer Lock Connector
Our ISO 80369-7 Figure C.6 Male Reference Connector is the premium testing tool designed specifically for evaluating female luer lock connectors according to international ISO 80369-7 standards. This precision-engineered male reference connector ensures accurate assessment of axial load separation resistance and override resistance performance in medical fluid connections. Key Features: Fully compliant with ISO 80369-7 Figure C.6 specifications for luer connector testing
ISO 80369-7-Figure C.5 Female Reference Luer Slip Connector For Testing Male Luer Connectors
This ISO 80369-7 Figure C.5 compliant female reference luer slip connector is specifically designed for testing male luer connectors according to international standards. It serves as the reference device for evaluating leakage resistance, separation force under axial load, stress cracking susceptibility, and non-interconnectable characteristics with other small-bore connectors. Key Features: Precision Machined - Exact dimensions per ISO 80369-7 Figure C.5 specifications
ISO 80369-7-Figure C.4 Male Reference Luer Lock Connector For Testing Female Luer Connectors
ISO 80369-7: 2017 Small-bore connectors for liquids and gases in healthcare applications - Part 7: Connectors for intravascular or hypodermic applications a. Maximum distance from tip of male luer lock connector to the first complete profile of the internal thread (see Table B.3, dimension t). b. Double-start, right-hand thread of 2,5 mm pitch. NOTE : R may be 0,5 mm (maximum) × 45° chamfer. This ISO 80369-7 Figure C.4 Male Reference Luer Lock Connector is a high-precision
ISO 80369-7-Figure C.3 Female Reference Connector For Testing Male Luer Lock Connector
Our precision-engineered ISO 80369-7 Figure C.3 female reference connector is specifically designed for testing male luer lock connectors according to international standards. This essential medical device testing equipment enables accurate evaluation of axial load separation resistance and override resistance in luer lock connections, ensuring compliance with ISO 80369-7 standards for small-bore connectors.This female test connector serves as the standardized reference
ISO 80369-7-Figure C.2 Male Reference Luer Slip Connector For Testing Female Luer Connectors
ISO 80369-7: 2017 Small-bore connectors for liquids and gases in healthcare applications - Part 7: Connectors for intravascular or hypodermic applications NOTE 1 Cone taper (0,06:1). NOTE 2 R may be 0,5 mm (maximum) × 45° chamfer. The minimum length of the male taper of 10,5 mm is required for testing non-interconnectable characteristics. A minimum length of the male taper of 7,5 mm may be used for the performance tests of Clause 6. ISO 80369-7-Figure C.2 Male Reference Luer
ISO 80369-7-Figure C.1 Female Reference Luer Lock Connector For Testing Male Luer Connectors
ISO80369-7-Figure C.1 Female reference luer lock connector for testing male luer connectors for leakage, separation from unscrewing, stress cracking and non-interconnectable characteristics. Our ISO 80369-7 Figure C.1 compliant female reference luer lock connector is the industry-standard testing device specifically designed for evaluating male luer connectors according to international medical standards. This precision-engineered luer lock testing equipment enables
IEC60601-1-11 & IEC60601-1-12 Altitude Simulation Chamber / Decompression Chamber
Altitude Simulation Chamber (Decompression Chamber) - IEC60601-1-11 & IEC60601-1-12 Compliant 1. Product Overview The Altitude Simulation Chamber is a precision-engineered decompression testing system designed for medical device validation, aerospace testing, and high-altitude research. Fully compliant with IEC60601-1-11 and IEC60601-1-12 standards, this chamber provides accurate atmospheric pressure simulation from 500hPa to 1013hPa (equivalent to 5,000m altitude to sea
ISO 80601-2-69 Figure 21.101 Standard Resistance For Test Equipment
ISO 80601-2-69 figure 21.101 standard resistance 201.9.6.2.1.101 Additional requirements for audible acoustic energy a) The A-weighted sound pressure level emitted by the oxygen concentrator, when tested in accordance with the method in this subclause, shall be disclosed in the instructions for use: 1) for an oxygen concentrator with a continuous flow mode, i) at a flowrate setting of 3 l/min, or ii) the maximum flowrate setting if this is less than 3 l/min, iii) as well as
304 Steel Obstruction 15mm Rectangular Cross Section IEC 60601-1
IEC 60601-1 304 Steel Obstruction Rectangular Cross Section IEC 60601-1 304 steel Obstruction a solid vertical plane obstruction with a rectangular cross-section, 15 mm high and at least 20 mm wide that is affixed flat on the floor. The upper corners of the obstruction may have radiuses of up to 2 mm applied.
IEC 60601-1 304 Steel Obstruction Rectangular Cross Section
IEC 60601-1 304 steel Obstruction The obstruction (304 steel) have a rectangular cross section of 10 mm ± 0.5 mm high and at least 80 mm wide with a radius of 2 mm± 0.1 mm at the top edges. Length 1.2meter.
ISO 18250-3 Figure C.6 Female Reference Connector For Reservoir Delivery Systems
ISO 80369-3 Figure C.5 Female Reference Connectors ISO 80369-3 Small-Bore Connectors for Liquids and Gases in Healthcare Applications - Part 3: Connectors for Enteral Applications; ISO 80369-3 Figure C.5 Female Reference Connector is for testing male enteral reservoir connector for: ISO 18250-3 Clause 6.2: Positive Pressure Liquid Leakage ISO 18250-3 Clause 6.3: Subatmospheric Pressure Air Leakage ISO 18250-3 Clause 6.4: Stress Cracking ISO 18250-3 Clause 6.5: Resistance To
ISO 18250-3 Figure C.5 Male Reference Connector For Healthcare Applications
ISO 80369-3 Figure C.5 Male Reference Connectors ISO 80369-3 Small-Bore Connectors for Liquids and Gases in Healthcare Applications - Part 3: Connectors for Enteral Applications; ISO 80369-3 Figure C.5 Male Reference Connector is for testing female enteral reservoir connector for: ISO 18250-3 Clause 6.2: Positive Pressure Liquid Leakage ISO 18250-3 Clause 6.3: Subatmospheric Pressure Air Leakage ISO 18250-3 Clause 6.4: Stress Cracking ISO 18250-3 Clause 6.5: Resistance To
ISO 18250-3 Figure C.4 Cross Reference Connector For Reservoir Delivery Systems
ISO 80369-3 Figure C.4 Cross Reference Connectors ISO 80369-3 Small-Bore Connectors for Liquids and Gases in Healthcare Applications - Part 3: Connectors for Enteral Applications; ISO 80369-3 Figure C.4 Cross Reference Connectors is for testing cross port reservoir connector for: ISO 18250-3 Clause 6.5: Resistance To Separation From Axial Load ISO 18250-3 Clause 6.7: Resistance To Overriding
ISO 18250-3 Figure C.3 Reference Connector For Reservoir Delivery Systems
ISO 80369-3 Figure C.3 Cross Reference Connectors ISO 80369-3 Small-Bore Connectors for Liquids and Gases in Healthcare Applications - Part 3: Connectors for Enteral Applications; ISO 80369-3 Figure C.3 Cross Reference Connectors is for testing cross port reservoir connector for: ISO 18250-3 Clause 6.2: Positive Pressure Liquid Leakage ISO 18250-3 Clause 6.3: Subatmospheric Pressure Air Leakage ISO 18250-3 Clause 6.4: Stress Cracking ISO 18250-3 Clause 6.6: Resistance To
ISO 18250-3 Figure C.2 Cross Port Reservoir Reference Connector For Enteral
ISO 80369-3 Figure C.1 and C.2 Female Reference Connectors ISO 80369-3 Small-Bore Connectors for Liquids and Gases in Healthcare Applications - Part 3: Connectors for Enteral Applications; Annex C; Figure C.1 and Figure C.2 define the Female Reference Connectors are used in the tests specified in ISO 80369-3, Clause 6. Keeping with the experienced requirements of the medical industry; these ISO 80369-3 Figure C.1 and C.2 Female Reference Connectors are made from hardened
Enteral Application ISO 18250-3 Reference Connector For Reservoir Delivery Systems
ISO 80369-3 Figure C.1 and C.2 Female Reference Connectors ISO 80369-3 Small-Bore Connectors for Liquids and Gases in Healthcare Applications - Part 3: Connectors for Enteral Applications; Annex C; Figure C.1 and Figure C.2 define the Female Reference Connectors are used in the tests specified in ISO 80369-3, Clause 6. Keeping with the experienced requirements of the medical industry; these ISO 80369-3 Figure C.1 and C.2 Female Reference Connectors are made from hardened