KingPo Technology Development Limited
                                                                                                           
Verified Supplier
26 Years
Since 2000
Menu
Home Products Medical Test Equipment

Medical Test Equipment

China ASTM D5035 Disposable Mask Band Breaking Strength Tester for Ear Loop Tensile Test for sale

ASTM D5035 Disposable Mask Band Breaking Strength Tester for Ear Loop Tensile Test

Price: To be Quoted
MOQ: 1
Delivery Time: 7 Days

ASTM D5035 Disposable Mask Band Breaking Strength Tester The KingPo Technology Mask Band Breaking Strength Tester is designed to test the tensile strength and breaking force of mask ear loops, mask bands, and their connection points with the mask body. This equipment is suitable for disposable medical masks, surgical masks, protective masks, and other mask products requiring reliable strap strength testing. Product Overview For mask manufacturers and quality inspection

China Loading pad, BS EN 50637:2017-Figure 201.103 for sale

Loading pad, BS EN 50637:2017-Figure 201.103

Price: To be quoted
MOQ: 1
Delivery Time: 7 working days

Loading pad, BS EN 50637:2017-Figure 201.103 Loading pad designed according to the standard BS EN 50637:2017-Figure 201.103 Model KP-06373 According to standard BS EN 50637:2017-Figure 201.103

China Impactor, BS EN 50637:2017-Figure 201.104 for sale

Impactor, BS EN 50637:2017-Figure 201.104

Price: To be quoted
MOQ: 1
Delivery Time: 7 working days

Impactor, BS EN 50637:2017-Figure 201.104 Impactor designed according to the standard BS EN 50637:2017-Figure 201.104. Constructed from steel with a total weight of 17 ± 0.1kg. Model KP-06374 Standard BS EN 50637:2017-Figure 201.104 Total Weight 17 ± 0.1kg Surface Roughness 1.6μm Material Steel Product Images

China IEC 60601-2-52 Medical Bed Tester, Side rail strength and latch reliability tester for sale

IEC 60601-2-52 Medical Bed Tester, Side rail strength and latch reliability tester

Price: To be quoted
MOQ: 1
Delivery Time: 7 working days

IEC 60601-2-52 Medical Bed Tester, Side rail strength and latch reliability tester IEC 60601-2-52 Medical Bed Tester, Side rail strength and latch reliability tester It meets the strength test of the side rails of Medical hospital beds in accordance with IEC 60601-2-52 "Medical electrical equipment - Part 2-52: Particular requirements for the basic safety and essential performance of medical beds" standard. It is designed and manufactured in accordance with the requirements

China IEC 60601-2-52 Medical Bed Tester -Impactor for sale

IEC 60601-2-52 Medical Bed Tester -Impactor

Price: To be quoted
MOQ: 1
Delivery Time: 7 working days

IEC 60601-2-52 Medical Bed Tester - Impactor Product Description IEC 60601-2-52 - figure BB.2 Medical Bed Tester - Impactor BB.2.2 The effect of impacts to the MATTRESS SUPPORT PLATFORM The MEDICAL BED shall be able to withstand the effect of impacts to the MATTRESS SUPPORT PLATFORM being applied during NORMAL USE. Compliance Test Procedure Place the mattress, as specified by the MANUFACTURER, onto the MATTRESS SUPPORT PLATFORM Position moving elements free of supporting

China IEC 60601-2-52 Medical Bed Tester,Dynamic forces due to loading from persons, Medical Beds Strength and durability tester for sale Video

IEC 60601-2-52 Medical Bed Tester,Dynamic forces due to loading from persons, Medical Beds Strength and durability tester

Price: To be quoted
MOQ: 1
Delivery Time: 7 working days

IEC 60601-2-52 Medical Bed Tester Dynamic forces due to loading from persons, Medical Beds Strength and durability tester According to IEC60601-2-52 Section 201.9.8.3.3.1 for dynamic loading force tests from human weight According to IEC60601-2-52 Appendix CC.2.2 Impact test of mattress support table According to IEC60601 section 9.4.2.3 Instability According to IEC60601 section 9.8.3.3 human body test mass IEC60601 section 9.8.3.3 Extension mode: motor drive Impact height: 0

China IEC60601-Clause 9.8.3.3 For Dynamic Loading Force Tests From Human Weight for sale Video

IEC60601-Clause 9.8.3.3 For Dynamic Loading Force Tests From Human Weight

Price: To be quoted
MOQ: 1
Delivery Time: 7 working days

Dynamic forces due to loading from persons- IEC60601-Clause 9.8.3.3 1. According to IEC60601-2-52 Section 201.9.8.3.3.1 for dynamic loading force tests from human weight. According to IEC60601-2-52 Appendix CC.2.2 Impact test of mattress support table. According to IEC60601 section 9.4.2.3 Instability. According to IEC60601 section 9.8.3.3 human body test mass. 2 IEC60601 section 9.8.3.3 2.1) Extension mode: motor drive 2.2) Impact height: 0~300mm adjustable 2.3) Material of

China ISO 20696 Apparatus For Testing Sterile Urethral Catheters Until Kinking for sale

ISO 20696 Apparatus For Testing Sterile Urethral Catheters Until Kinking

Price: To be quoted
MOQ: 1
Delivery Time: 30 working days

ISO 20696 Apparatus for testing Sterile urethral catheters until kinking

China IEC 60601-1 ME Equipment Rough Handling Tester AC 220V 50/60HZ for sale

IEC 60601-1 ME Equipment Rough Handling Tester AC 220V 50/60HZ

Price: To be quoted
MOQ: 1
Delivery Time: 30 working days

ME Equipment Rough Handling Tester Comply with IEC60601-1,GB9706.1-2020 standard 9.4.2.4.2, 9.4.2.4.3, 15.3.5 chapter requirements Technical parameters: 1. Power supply: AC 220V 50/60HZ 2, driving mode: servo motor, horizontal drive, automatic simulation of human hands to push ME equipment to cross the threshold of motion and rough handling test. 3, Speed: 0.8m/s± 0.1m /s (speed 0-2m/s can be set) 4, pushing force range: 0-2000N, accuracy: ± 1% 5, count: 0~9999 times can be

China IEC 60601-2-52 Medical Beds Side Rail Strength And Latch Reliability Tester for sale

IEC 60601-2-52 Medical Beds Side Rail Strength And Latch Reliability Tester

Price: To be quoted
MOQ: 1
Delivery Time: 30 working days

IEC 60601-2-52 Medical beds side rail strength and latch reliability tester According to standard IEC 60601-2-52-cl.201.9.8.3.3.3 Through PLC program control, 7 inch touch screen display, the use of electric cylinder to apply the test required force value, through high-precision sensor automatic data acquisition, can be arbitrarily set the test load value, load application time, test force peak acceleration capture function, maintain force stability function, reach the set

China Iso / Dis 18193 2020 Annex B Kink Resistance Test Set Up for sale

Iso / Dis 18193 2020 Annex B Kink Resistance Test Set Up

Price: To be quoted
MOQ: 1
Delivery Time: 7 working days

ISO/DIS 18193:2020- Cardiovascular implants and artificial organs — Cannulae for extracorporeal circulation ISO/DIS 18193:2020-Annex B Test set-up for kink resistance

China Female Reference Conical Fitting For Testing Male 6% Luer Lock Fittings For Separation Force And R for sale

Female Reference Conical Fitting For Testing Male 6% Luer Lock Fittings For Separation Force And R

Price: To be quoted
MOQ: 1
Delivery Time: 7 working days

ISO/DIS 18193:2020- Cardiovascular implants and artificial organs — Cannulae for extracorporeal circulation ISO/DIS 18193:2020-Figure A.11 — Female reference conical fitting for testing male 6 % (Luer) lock fittings for separation force and resistance to overriding Packaging

China Steel Female Conical Fitting Iso / Dis 18193 2020-Figure A.4 Reference for sale

Steel Female Conical Fitting Iso / Dis 18193 2020-Figure A.4 Reference

Price: To be quoted
MOQ: 1
Delivery Time: 7 working days

ISO/DIS 18193:2020- Cardiovascular implants and artificial organs — Cannulae for extracorporeal circulation ISO/DIS 18193:2020-Figure A.4 Reference steel female conical fitting Packaging

China Iso 80601-2-12 Test Conditions For Acoustic Tests Test Lung for sale

Iso 80601-2-12 Test Conditions For Acoustic Tests Test Lung

Price: To be quoted
MOQ: 1
Delivery Time: 5 working days

ISO 80601-2-12 Test conditions for acoustic tests -test lung Adjustable parameter Test condition For a ventilator intended to provide tidal volume VT ≥ 300 ml 300 ml ≥ VT ≥ 50 ml VT ≤ 50 ml Tidal volume, VTa 500 ml 150 ml 30 ml Set rate 10 breaths/min 20 breaths/min 30 breaths/min I:E ratio 1:2 1:2 1:2 BAP 10 hPa (10cmH2O) 10 hPa (10cmH2O) 10 hPa (10cmH2O) Linear resistance,Rb 5 hPa·(l/s) −1 ±10% 20hPa·(l/s)−1 ±10% 50hPa·(l/s)−1 ±10% Isothermal Compliance, Cb 50 ml·hPa −1 ±10

China ISO 18250-1 Subatmospheric Pressure Air Leakage Tester With Result Printing for sale Video

ISO 18250-1 Subatmospheric Pressure Air Leakage Tester With Result Printing

Price: To be quoted
MOQ: 1
Delivery Time: 25 working days

ISO 80369-20:2015 and ISO 18250-1:2018 Annex D Subatmospheric Pressure Air Leakage Tester with test result printing function Technical parameters ●According to standards: ISO80369-20-Annex D ●Pressure gauge range:0~-80kpa ●Pressure gauge accuracy: ±0.25%FS ●Test time: 0-9999s Can be set ●Test time: 0-9999s Can be set ●Control mode: PLC+7 inch touch screen ●Output and input pipe size: φ4mm ●Dimensions: 360*380*210 mm W * D *h ●Weight: 11.5kg ●Power supply: 220V 50HZ This

China ISO 80601-2-70 Figure 21.101 Standard Resistance Medical Test Equipment for sale

ISO 80601-2-70 Figure 21.101 Standard Resistance Medical Test Equipment

Price: To be quoted
MOQ: 1
Delivery Time: 5 working days

ISO 80601-2-70 figure 21.101 standard resistance Key D is the internal diameter: (4 ± 0,1) mm L is the length: (40 ± 1) mm A is the angle (45 ± 1) ° Break all edges with 0,15 mm to 0,20 mm radius or 45° chamfer. Drawing is not to scale. Connector: 15/22mm standard connector can be made according to customer requirements

China Iso 18193-Figure C.2 Vascular Model Of Superior Vena Cava Right Atrium For Testing Dual Lumen Cannula Recirculation for sale

Iso 18193-Figure C.2 Vascular Model Of Superior Vena Cava Right Atrium For Testing Dual Lumen Cannula Recirculation

Price: To be quoted
MOQ: 1
Delivery Time: 7 working days

ISO18193:2021- Cardiovascular implants and artificial organs — Cannulae for extracorporeal circulation ISO18193:2021-Annex C Test set-up for recirculation Figure C.1 — Circuit for recirculation testing of dual-lumen cannula using ink or particles. Figure C.2 — Vascular model of superior vena cava, right atrium, and inferior vena cava for testing dual-lumen cannulae recirculation

China KP-1230S Dielectric Strength Tester for Quadripolar Connector Testing with Monophasic Truncated Exponential Waveform Compliant with ISO 27186:2020 for sale Video

KP-1230S Dielectric Strength Tester for Quadripolar Connector Testing with Monophasic Truncated Exponential Waveform Compliant with ISO 27186:2020

Price: Negotiable
MOQ: 1
Delivery Time: 20

KP-1230S Dielectric Strength Tester Compliant with ISO 27186:2020 Annex C Product Overview The KP-1230S Dielectric Strength Tester is a professional test instrument designed to generate test pulses for evaluating quadripolar connector systems in active implantable medical devices. Engineered in strict accordance with YY/T 0972-2016 Appendix C requirements, this system tests whether implantable cardiac rhythm management devices experience permanent damage when subjected to

China ISO 5362 Compliant Anesthesia Breathing Bags Leakage Tester with 0-100kpa Pressure Range and 0-100ml/min Flow Range for sale

ISO 5362 Compliant Anesthesia Breathing Bags Leakage Tester with 0-100kpa Pressure Range and 0-100ml/min Flow Range

Price: To be quoted
MOQ: 1
Delivery Time: 20 working days

ISO 5362 Anesthesia Breathing Bags Leakage Tester The ISO 5362 Anesthesia Breathing Bags Leakage Tester is designed to evaluate the leakage rate of anesthesia breathing bags in compliance with ISO 5362 standards. Product Description This specialized tester is manufactured according to ISO 5362 Annex A requirements for precise measurement of anesthesia breathing bag leakage rates. Specifications Standard Compliance ISO 5362-Annex A Pressure Range 0-100kPa Pressure Accuracy ±0

China IEC 60601-2-34 Figure 202.102 Test circuit for high-frequency surgery interference measurement for sale

IEC 60601-2-34 Figure 202.102 Test circuit for high-frequency surgery interference measurement

Price: To be quoted
MOQ: 1
Delivery Time: 20 working days

IEC 60601-2-34 Figure 202.102 Test circuit for high-frequency surgery interference measurement IEC 60601-2-34 Figure 202.102 Test circuit for high-frequency surgery interference measurement