Fire Pump Set
HSC UL Fire Pump Set With TECHTOP Engine And Tornatech Controller 1000GPM 150PSI
HSC UL Fire Fighting motor Pump sets with TECHTOP Engine and Tornatech Controller 1000GPM 150PSI Product Details 1 Motor Pump Set Pump: NM Fire Split Case Model: SCF150-100-320(UL) Q=1000usgpm H=150psi n=2980rpm Material: Casing---Ductile Cast iron Impeller---SS304 Shaft--- AISI 4340 Shaft sleeve---SS304 Seal------ Gland packing Wear ring----Bronze Bearing---SKF Engine: TECHTOP&UL Model: TDC 405TS150U2B 110KW/50HZ/380V/3PH Controller : Tornatech Application: Industrial fields
Horizontal Split Case Fire Pump Set Driven by De Maas Fire Diesel Engine FM Approved
Horizontal Split Case Fire Pump Set Driven by De Maas Fire Diesel Engine FM Approved Configuation: Pump NM Fire Split Case Model SCF125-80-350G Rated flow 750 GPM Rated head 120m Speed 2980 rpm Engine Demaas FM Approved Controller Tornatech GPD series Fuel Tank NM Fire 600L double wall Jockey pump CNP CDL20-10 Single stage horizontal split case fire pump for firefighting applications. NFPA-20 design. UL Listed and FM Approved. HSC Pumps are engineered for reliable operation
2000 GMP Double Suction Diesel Engine Fire Pump Set With UL / FM Certificates Be accordance with NFPA 20
2000 GMP Double Suction Diesel Engine Fire Pump Set With UL / FM Certificates Be accordance with NFPA 20 Main Parameters: Pump NM Fire Split Case Type: SCF200-150-330 Rated Flow: 2000 usgpm Rated Head: 90m Speed: 2980rpm Engine: NM Fire Type: NM6-110D 121HP Fuel tank NM Fire 1000L single wall Controller: Tornatech Type: GPD-24-220/240 Jockey pump CNP CDL12-9 Motor Techtop F-TDC444TS200U2B Controller Tornatech GPY-380V/200HP/3PH/50HZ Horizontal Split Case (HSC) pumps are given
Firefighting Split Case Centrifugal Pump 205PSI For Office Building / Schools
Ductile Cast Iron Made UL/FM/NFPA20 Certification Centrifugal Fire Pump For Firefighting Application Horizontal Split Case: Horizontal split case pumps are the most common type of fire pump. These pumps are specifically designed and tested for fire service applications where reliability of performance is of vital importance. Split case pumps are characterized by: • Easy access to all working parts; • Rugged construction; • Liberal water passages; and • Efficient operation.
Ductile Cast Iron Centrifugal Fire Pump 170PSI 120m For Office Building
Ductile Cast iron Made Split Case Centrifugal Fire Pump Capacity With UL/FM/NFPA20 Certification split case fire pumps that meet NFPA standards , as well as being UL listed, FM approved. Fire pump sets are available with electric motor and diesel engine driver. Every pump is subjected to a thorough inspection and a series of tests to ensure that it meets the required specifications before leaving the factory. KEY FEATURES Complete compact unit Horizontal Tailored to the
750GPM@120PSI Fire Fighting Water Pump With With Air / Water Cooling Method
Ductile Cast iron Made Centrifugal Fire Pump Capacity With UL/FM/NFPA20 Certification 750GPM @ 120PSI Centrifugal End Suction Pump Series with Hydraulically balanced impeller to extend bearing life. Available in electric motor or diesel engine driven configurations. Capacity to 750 GPM Pressures to 225 PSI Features and Benefits Top centerline discharge with foot supported casing. Ease of installation. Simplifies piping layout. Reduces problems associated with piping strain.
Industrial High Pressures Split Case Fire Pump Centrifugal 1000GPM / 175PSI
Split Case Fire Pump UL/FM/NFPA20 Certification Centrifugal Fire Pump Capacity For Firefighting Applications The Split Case Fire Pump is designed to provide water to stand pipe, sprinkler, chemical mitigation and hydrant systems for fire supression in industrial and commercial facilities. Features and Benefits: Available in capacities up to 4,000 GPM Pressures up to 205 PSI In compliance with NFPA #20, UL or FM Performance and hydrostatic tests. Dynamic balance impellers.
High Efficiency Centrifugal Fire Pump 4000Usgpm Ductile Cast Iron Materials
Ductile Cast Iron UL/FM/NFPA20 Certification Centrifugal Fire Pump Capacity Up To 4000Usgpm How it Works: The most common split case pump is a single-stage, between bearing, non-self-priming centrifugal volute pump. The design of the pump allows for easy removal of the pump’s top casing to enable easy access to the pump’s components without interfering with the motor or the piping system. The independent bearing casing allows for easy maintenance without the need for
High Precision Centrifugal Fire Pump 1000GPM /145PSI For Storage Warehouses
1000GPM @ 145PSI UL/FM/NFPA20 Certification Centrifugal Fire Pump Capacity For Firefighting Applications The fire pump starts when the pressure in the fire sprinkler system drops below a threshold. The sprinkler system pressure drops significantly when one or more fire sprinklers are exposed to heat above their design temperature, and opens, releasing water. Alternately, other fire hoses reels or other firefighting connections are opened, causing a pressure drop in the fire
Horizontal Single Stage Centrifugal Pump NFPA20 Standard 195.9KW Max Shaft Power
For Firefighting Applications 750GPM @ 195PSI Centrifugal Fire Pump Capacity UL/FM/NFPA20 Certification A split case pump is a type of centrifugal pump in which the pump’s casing is split into two separate chambers. This type of pump is different from an inline pump or an end suction pump in which the discharge nozzle and the suction nozzle are both included in one chamber. There are two main types of the split case pump. When the casing is split along a vertical plane with
NFPA Standard Double Suction Split Case Pump Centrifugal 2500GPM@135PSI
UL List FM Approval Centrifugal Split case Fire Pump With the Capacity Up To 2500GPM @ 135PSI Parameters: HEAD PUMP MODEL SPEED MAX SHAFT POWER PSI FEET METER RPM HP KW 135 312 95 SCF250-200-430 (10x8") 1800 (60Hz) 375 279.4 Centrifugal Split Case Pump : A split case pump is a type of centrifugal pump in which the pump’s casing is split into two separate chambers. This type of pump is different from an inline pump or an end suction pump in which the discharge nozzle and the
High Efficiency Centrifugal Fire Pump 2000GPM Capacity NFPA20 Certification
UL/FM/NFPA20 Certification Centrifugal Fire Pump With the Capacity 2000GPM @ 190PSI Parameters: HEAD PUMP MODEL SPEED MAX SHAFT POWER PSI FEET METER RPM HP KW 190# 437# 134# SCF200-150-460 (8x6") 1800 (60Hz) 410 305.5 How it Works: The most common split case pump is a single-stage, between bearing, non-self-priming centrifugal volute pump. The design of the pump allows for easy removal of the pump’s top casing to enable easy access to the pump’s components without interfering
3000GPM 125PSI Single Stage Double Suction Centrifugal Pump For Firefighting
UL/FM/NFPA20 Certification 3000GPM @ 125PSI Centrifugal Fire Pump Capacity For Firefighting Applications Horizontal Split Case The protection of life is not a matter for compromise This is particularly true for fire protection systems where they are only as strong as their 'weakest link' and compromise may result in avoidable loss of life or property. That is why NM fire pumps are designed specifically for the very particular needs of fire protection and are approved by most
Split Case Pump Diesel Driven Fire Pump Firefighting Water or Sea water
Split Case Pump Diesel Driven Fire Pump Firefighting Water or Sea water Fire Pumps are used to supply water for automatic sprinkler systems, standpipes or fire hydrants. NFPA No. 20 classifies fire pumps as split case, vertical turbine, end suction, or In-Line design. In-Line fire pumps have capacities of 50, 75, 100, 150, 200, 250, 300, 400, 450, 500, and 750 GPM; End Suction pumps are rated for 100, 200, 250, 300, 400, 450, 500, and 750 GPM; Split case and vertical turbine
NFPA 20 Standard Cummins Diesel Fire Pump Engine 24KW - 1227KW CCCS Certification
NFPA 20 Standard Cummins Diesel Fire Pump Engine 24KW - 1227KW CCCS Certification Description Engine Series - Cummins QSB4.5 Exhaust Emissions - EPA Tier3 When performance matters,we take notice.Our engines ar e an assurance of safety specifically designed to fit your needs.The cummins CFP5E fire pump drive engine features a cast-iron parent bore block structurally designed to reduce noise and increase durability. Standards NFPA20 EN12845 Performance Ranges Power : 24Kw
Stainless Steel Material Vertical Type Jockey Pump With NFPA 20 Standard
Stainless Steel Material Vertical Type Jockey Pump For Fire Pump Set In Line With NFPA 20 Standard A jockey pump is also known as a pressure maintenance system pump. The pump is a very important component in a fire pump system as well as the entire fire protection system. It is designed to maintain the pressure in a fire sprinkler protection system elevated to a certain level when the system is not active. This is meant to ensure that the fire pump does not have to operate
NFPA20 Fire Pump Set With Vertical Multistage Electric Motor Driven , Jockey Pump Set
NFPA20 Fire Pump Set With Vertical Multistage Electric Motor Driven , Jockey Pump Set A jockey pump is a pump connected to a fire sprinkler system and is intended to maintain pressure in a fire protection piping system to an artificially high level so that the operation of a single fire sprinkler will cause a pressure drop which will be sensed by the fire pump automatic controller, causing the fire pump to start. The jockey pump is essentially a portion of the fire pump's
Jockey pump 50 / 60 hz Pressure Maintain Pump CDL Series Worked for Fire Fighting System
Jockey pump 50 / 60 hz Pressure Maintain Pump CDL Series Worked for Fire Fighting System The jockey pump shall be used to maintain a constant water pressure inside the fire fighting ring main. The jockey pump shall therefore automatically start on low pressure set point and shall stop once the pressure has been raised to the normal operating pressure of the fire fighting system. The normal operating pressure of the system shall be determined according to the rquirements of
NFPA20 Standard Electric Motor Driven Fire Pump Set , Ul Fm Pump For Fire Fighting Use
NFPA20 Standard Electric Motor Driven Fire Pump Set , Ul Fm Pump For Fire Fighting Use Horizontal split case pumps are the most common type of fire pump. These pumps are specifically designed and tested for fire service applications where reliability of performance is of vital importance. Split case pumps are characterized by: • Easy access to all working parts; • Rugged construction; • Liberal water passages; and • Efficient operation. Split case fire pumps are specified
UL / FM Listed Split Case Single Stage Fire Pump Set With NFPA 20 Standard
UL / FM Listed Split Case Single Stage Fire Pump Set With NFPA 20 Standard Main Parameters: Pump NM Fire Split Case Type: SCF150-125-250 Rated Flow: 1000usgpm Rated Head: 90m Speed: 2980rpm Engine: NM Fire Type: NM4-108B 121HP Fuel tank NM Fire 600L single wall Controller: Tornatech Type: GPD-24-220/240 Jockey pump CDL10-11 Split Case Pump A split case pump is a type of centrifugal pump in which the pump’s casing is split into two separate chambers. This type of pump is