Differential Circuit Breaker
NBSE Fire Resistant Differential Switch Circuit Breaker NFC62411
NBSe africa type 2p/4p adjustable PG type earth leakage circuit breaker The DDC breaker is divided into 2 poles and 4 poles. It can be applied to the circuit breaker installed on the control panel of the primary equipment, and can also be applied to the control terminal of the shopping mall, base station and home power supply board. Feature 1)This product has a high level of safety protection. 2)Not affected by ambient temperature. 3)Multi-step adjustable of rated current. 4
Nbse 2fils 4 Fils PG 4 Pole MCCB Circuit Breaker , Earth Leakage Device
NBSe 2fils 4 fils PG 10-30A 30-60A France disjoncteur 500mA circuit breaker specifictions CE,CERTIFICATED .Quality guarantees 2 years .Professional manufacture for more than 20 years We can supply all kinds of MCCB ODM and OEM orders are welcome. 1) Applicable circuit: AC 50Hz (or 60Hz) 2) Rated insulation voltage: 690V 3) Rated operating voltage: up to 660V (690V) 4) Rated operating voltage: up to 250V(DC) 5) Rated operating current: 63A-800A 6) For distributing energy of
DDC 500mA Single Three Phase Differential Circuit Breaker Earth Leakage Selective Branch
NBSe DDC 300mA 500mA Earth Leakage Selective Branch Single Three Phase Circuit Breaker 1. Detailed Baco Type Circuit Brekaer Description Features: a) A compact and diversified range b) All the 2 and 4 poles devices have the same depth and the overall dimensions are reduced according to the 4 poles version c) Consumer combined circuit breaker: 2 and 4 poles 500mA, 500mA selective () and non residual current circuit breaker d) Ratings from 15A to 90A e) Residual current circuit
DDC Double Pole Differential Circuit Breaker NFC61450 Rcbo Protection Device
NBSe DDC 4P 30-60A France disjoncteur 500mA circuit breaker 30-45-60A 1. Application The DDC breaker is divided into 2 poles and 4 poles. It can be applied to the circuit breaker installed on the control panel of the primary equipment, and can also be applied to the control terminal of the shopping mall, base station and home power supply board. Feature as below: 1)This product has a high level of safety protection. 2)Not affected by ambient temperature. 3)Multi-step
Adjustable Current DDC230 Rcbo Circuit Breaker NFC62411
NBSe RCBO: Sell Adjustable Current Leakage Circuit Breaker DDC230 - RCBO 1. Application The DDC breaker is divided into 2 poles and 4 poles. It can be applied to the circuit breaker installed on the control panel of the primary equipment, and can also be applied to the control terminal of the shopping mall, base station and home power supply board. Feature as below: 1)This product has a high level of safety protection. 2)Not affected by ambient temperature. 3)Multi-step
DDC 500mA Single Three Phase Selective Branch Differential Circuit Breaker
NBSe DDC 300mA 500mA Earth Leakage Selective Branch Single Three Phase Circuit Breaker 1. Detailed Baco Type Circuit Brekaer Description Features: a) A compact and diversified range b) All the 2 and 4 poles devices have the same depth and the overall dimensions are reduced according to the 4 poles version c) Consumer combined circuit breaker: 2 and 4 poles 500mA, 500mA selective () and non residual current circuit breaker d) Ratings from 15A to 90A e) Residual current circuit
Compact 240v 3 Phase Module Case Circuit Breaker 2P Poles
NBSe Compact 240v 415v 30a 60a 3 phase 500ma earth leakage molded case circuit breaker 1. Application The DDC breaker is divided into 2 poles and 4 poles. It can be applied to the circuit breaker installed on the control panel of the primary equipment, and can also be applied to the control terminal of the shopping mall, base station and home power supply board. Feature as below: 1)This product has a high level of safety protection. 2)Not affected by ambient temperature. 3
Nbse Earth Leakage Differential Circuit Breaker 220v/240v High Fire Resistant
NBSe africa type 2p/4p adjustable PG type earth leakage circuit breaker The DDC breaker is divided into 2 poles and 4 poles. It can be applied to the circuit breaker installed on the control panel of the primary equipment, and can also be applied to the control terminal of the shopping mall, base station and home power supply board. Feature 1)This product has a high level of safety protection. 2)Not affected by ambient temperature. 3)Multi-step adjustable of rated current. 4
BHG PG 500mA Differential Circuit Breaker 10A-60A Molded Case Type 30-40-50-60A
baco circuit breaker, TG residual current circuit breaker TG BACO RCCB USED for AC 50/60HZ CE AND ISO9000 OEM PRCESSING BHG Breaker are suitable in AC 50Hz, 250/440V circuit with overload and earth leakage protection. The rated current is adjustable from 10A up to 60A. User can select suitable current to better protection against overload and short circuit. The products comply with NFC 61450. Features a) A compact and diversified range b) All the 2 and 4 poles devices have
Compact 240v 3 Phase Earth Leakage Circuit Breaker , Molded Case Circuit Breaker
NBSe Compact 240v 415v 30a 60a 3 phase 500ma earth leakage molded case circuit breaker 1. Application The DDC breaker is divided into 2 poles and 4 poles. It can be applied to the circuit breaker installed on the control panel of the primary equipment, and can also be applied to the control terminal of the shopping mall, base station and home power supply board. Feature as below: 1)This product has a high level of safety protection. 2)Not affected by ambient temperature. 3
Africa Type 2p/4p Adjustable Pg Type Differential Circuit Breaker 10-15-20-25-30a
NBSe africa type 2p/4p adjustable PG type earth leakage circuit breaker,5-10-15A/10-15-20-25-30A/15-30-45A/30-40-50-60A PG series adjustable residual current breaker(gardy rccb,gardy elcb)is suitable for AC 50/60Hz,230/400V circuit,prevents from overloading,short-circuit etc.On the occasion of shock hazard or earth leakage,it will trip immediately.At the same time,the rated current of overload protection can be adjustable. africa type 2p/4p adjustable PG type earth leakage
30ma Differential Switch Circuit Breaker , Double Pole Circuit Breaker Single Phase
NBSe Differential circuit breaker 30mA for 230V single-phase 1. Specification and Configuration POLE: 2P, 4P Ue: 230/400V In: 5-15A(5, 10, 15)A; 10-30A(10, 20, 30)A; 10-30A(10, 15, 20, 25, 30)A; 30-60A(30, 45, 60)A; 60-90A(60, 75, 90)A Breaking Capacity : 3KA 2. Application The DDC breaker is divided into 2 poles and 4 poles. It can be applied to the circuit breaker installed on the control panel of the primary equipment, and can also be applied to the control terminal of the
Nbse 2fils 4 Fils PG 4 Pole MCCB Circuit Breaker , Earth Leakage Device, 4 pole rcbo
Nbse 2fils 4 Fils PG 4 Pole MCCB Circuit Breaker , Earth Leakage Device, 4 pole rcbo specifictions CE,CERTIFICATED .Quality guarantees 2 years .Professional manufacture for more than 20 years We can supply all kinds of MCCB ODM and OEM orders are welcome. 1) Applicable circuit: AC 50Hz (or 60Hz) 2) Rated insulation voltage: 690V 3) Rated operating voltage: up to 660V (690V) 4) Rated operating voltage: up to 250V(DC) 5) Rated operating current: 63A-800A 6) For distributing
Nbse RCBO Earth Leakage Miniature Circuit Breaker Adjustable Current DDC230
NBSe RCBO: Sell Adjustable Current Leakage Circuit Breaker DDC230 - RCBO 1. Application The DDC breaker is divided into 2 poles and 4 poles. It can be applied to the circuit breaker installed on the control panel of the primary equipment, and can also be applied to the control terminal of the shopping mall, base station and home power supply board. Feature as below: 1)This product has a high level of safety protection. 2)Not affected by ambient temperature. 3)Multi-step
2p 4p Differential Circuit Breaker Baco Edf 340-45-60a Nfc62411 Standard
NBSe NFC62411 BACO EDF 2P 4P 5/15A 10/30A 15/45A 30/60A Circuit Breaker Specification and Configuration POLE: 2P, 4P Ue: 230/400V In: 5-15A(5, 10, 15)A; 10-30A(10, 20, 30)A; 10-30A(10, 15, 20, 25, 30)A; 30-60A(30, 45, 60)A; 60-90A(60, 75, 90)A Breaking Capacity : 3KA Application The DDC breaker is divided into 2 poles and 4 poles. It can be applied to the circuit breaker installed on the control panel of the primary equipment, and can also be applied to the control terminal
30-60a Adjustable Shunt Trip Circuit Breaker 30-45-60a France Disjoncteur
NBSe DDC 4P 30-60A France disjoncteur Adjustable Trip Circuit Bbreaker 30-45-60A 1. Application The DDC breaker is divided into 2 poles and 4 poles. It can be applied to the circuit breaker installed on the control panel of the primary equipment, and can also be applied to the control terminal of the shopping mall, base station and home power supply board. Feature as below: 1)This product has a high level of safety protection. 2)Not affected by ambient temperature. 3)Multi
NBSe DDC RCBO 2P Differential Circuit Breaker 10-30A 500mA 10-15-20-25-30A
NBSe DDC RCBO 2P Differential Circuit Breaker 10-30A 500mA 10-15-20-25-30A Advantage Our products have the guarantee period of 36 calendar months,that is a high quality and reliability; Our products have an excellent ratio between price and quality ,you can possess them by competitive price and high quality; The fast and flexible production form aim at the customer require; The deliveries exactly in accordance with customer orders The fast transportation. Adopt electromagneti
DDC Double Pole Circuit Breaker , 4 Pole Differential Switch Circuit Breaker
NBSe DDC 4P 30-60A France disjoncteur 500mA circuit breaker 30-45-60A 1. Application The DDC breaker is divided into 2 poles and 4 poles. It can be applied to the circuit breaker installed on the control panel of the primary equipment, and can also be applied to the control terminal of the shopping mall, base station and home power supply board. Feature as below: 1)This product has a high level of safety protection. 2)Not affected by ambient temperature. 3)Multi-step
Nbse 30-60a Differential Circuit Breaker 15-30-45a/30-40-50-60a Molded Case
baco circuit breaker, Factory design with more than 20 years production experience Normal operation and mounting requirement Circumstance temperature -5°C ~ +40°C, average temperature within 24h not exceeding +35°C. Altitude above sea level less than 2000 m. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C. Installation class II or III. Pollution class 2. Installation method DIN Rail mounting type. The external magnetism shall not be more than 5 times of