Rotating Anode X Ray Tube Assembly
White 150kV Rotating Anode X Ray Tube Assembly For CR / DR Machine Durable
Equivalent To:Toshiba E7876 150kV Rotating anode X‐Ray tube assembly for CR or DR machine Quick Detail: ◆ X-ray tube assembly for all routine diagnostic examinations with conventional or digital radiographic and fluoroscopic workstations ◆ The insert features: 12° Rhenium-Tungsten molybdenum target (RTM) ◆ Focal spots: Small 0.6, Large: 1.2 ◆ Maximum tube voltage: 150kV ◆ Accommodated with IEC60526 type high-voltage cable receptacles ◆ High voltage generator should accord
Diagnostic Examinations Rotating Anode X Ray Tube Assembly 12 ° Target Angle
Equivalent To:Toshiba E7876 150kV Rotating anode X‐Ray tube assembly for CR or DR machine Quick Detail: ◆ X-ray tube assembly for all routine diagnostic examinations with conventional or digital radiographic and fluoroscopic workstations ◆ The insert features: 12° Rhenium-Tungsten molybdenum target (RTM) ◆ Focal spots: Small 0.6, Large: 1.2 ◆ Maximum tube voltage: 150kV ◆ Accommodated with IEC60526 type high-voltage cable receptacles ◆ High voltage generator should accord
High Performance Rotating Anode X Ray Tube Assembly for medical x ray machine
150kV X‐Ray tube assembly Equivalent To Toshiba E7252/RAD14/RAY-14 Conditions for operation, storage and transport Limits Operation Limits Transport and Storage Limits Ambient temperature From 10℃to 40℃ From- 20℃to 70℃ Relative humidity ≤75% ≤93% Barometric pressure From 70kPa to 106kPa From 70kPa to 106kPa Stator key values 1-phase stator Test point C-P C-S Winding resistance ≈18.0…22.0Ω ≈45.0…55.0Ω Max. permissible operating voltage(run-up) 230V±10% Recommend operating
430 × 430mm Dental X Ray Machine , High Voltage Portable X Ray Machine
Equivalent To:Toshiba E7876 150kV Rotating anode X‐Ray tube assembly for CR or DR machine Description: .● The designation is composed as follows: SRMWHX7520 Tube A High voltage socket with 90 degree direction SRMWTX75-0.6/1.2-150 B High voltage socket with 270 degree direction Technical Data: Property Specification Standard Nominal input power(s) of the anode F 1 F 2 IEC 60613 20kW(50/60Hz) 50kW(50/60Hz) Anode heat storage capacity 163kJ (220kHU) IEC 60613 Maximum cooling
Dental X Ray Unit Rotating Anode X Ray Tube Assembly For Medical X Ray Machine
Rotating Anode X‐Ray tube assembly for medical x ray machine Description .● The designation is composed as follows: SRMWHX7360 Tube A High voltage socket with 90 degree direction SRMWTX73-0.6/1.2-150H B High voltage socket with 270 degree direction Technical Data Property Specification Standard Nominal input power(s) of the anode F 1 F 2 IEC 60613 20kW(50/60Hz) 30kW(150/180Hz) 50kW(50/60Hz) 74kW(150/180Hz) Anode heat storage capacity 212 k (300kHU) IEC 60613 Maximum cooling
Rotating Anode X Ray Equipment , 20KW / 46KW Powerful Mobile X Ray Unit
150kV Rotating Anode X‐Ray tube assembly Equivalent To Toshiba E7843/RAD12/RAY-12 for DR or CR Machine Description .● The designation is composed as follows: SRMWHX7420 Tube A High voltage socket with 90 degree direction SRMWTX74-0.6/1.2-150 B High voltage socket with 270 degree direction Quick Detail: ◆ X-ray tube assembly for all routine diagnostic examinations with conventional or digital radiographic and fluoroscopic workstations ◆ The insert features: 12° Rhenium
2800RPM Rotating Anode X Ray Tube Assembly 110kJ Anode Heat Storage Capacity
150kV X‐Ray tube assembly Equivalent To Toshiba E7843/RAD12/RAY-12 Technical Data Property Specification Standard Nominal input power(s) of the anode F 1 F 2 IEC 60613 20kW(50/60Hz) 46kW(50/60Hz) Anode heat storage capacity 110kJ (150kHU) IEC 60613 Maximum cooling capacity of the anode 475W Heat storage capacity 900kJ Max. continuous heat dissipation without Air-circular 180W Anode material Anode top coating material Rhenium-Tungsten-TZM(RTM) Rhenium-Tungsten-(RT) Target
1 Phase Stator 70V DC Digital X Ray Machine For Fluoroscopic Workstations
125kV Rotating anode X‐Ray tube assembly for CR or DR machine Equivalent To: Toshiba E7239 Stator key values 1-phase stator Test point C-M C-A Winding resistance ≈18.0…22.0Ω ≈45.0…55.0Ω Max.permissible operating voltage(run-up) 230V±10% Recommend operating voltage(run-up) 160V±10% Braking voltage 70VDC Run-on voltage in exposure 80Vrms Run-on voltage in fluoroscopy 20V-40Vrms Run-up time(depending on starter system) 1.2s Quick Detail: ◆ X-ray tube assembly for all routine