XLPE Power Cable
IEC/BS/UL/GB Copper Conductor 0.6/1kV XLPE Power Cable
Xlpe Insulated Electrical Power Cable 0.6/1kv With Copper Conductor Applications For laying indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces. Laying single core cable in magnetic ducts is not allowed. Certificates CE, SGS, KEMA and more others at request Ordering Advice Rated Voltage Application Standard: IEC/BS/UL/GB Number of Cores Conductor Size & Construction Type of Insulation Armored or unarmored. If armor, the
CU/XLPE/CTS/SWA/PVC Steel Wire Armoured Power Cable MV Copper Cable
Application Used in transformer stations, switching blocks, in electric power plants and industrial plants. Medium voltage power cable for static application in ground, within and outside facilities, outdoor, in cable canals, in water, in conditions where cables are not exposed to heavier mechanical stress and tensile strain. Construction Conductor Compact Stranded Copper Conductor, Class 2 as per IEC 60228 Circular solid Copper Conductor, Class 1 as per IEC 60228 Flexible
Underground XLPE Power Cable With 18KV 30KV Armored
Underground Power Cable With 18/30KV And Below And Steel Wire Armored Construction Conductor : Compact stranded copper conductor, Cl.2 as per IEC 60228 Conductor Screen: Semi-conductor Insulation : XLPE(cross-linked polyethylene) rated at 90 ℃ Insulation Screen: Semi-conductor Screen : Copper tape Interlining: PVC type ST2 to IEC 60502, black Armouring: SWA(Steel Wire Armouring) Sheath : PVC type ST2 to IEC 60502, black Standards: International: IEC 60502, IEC 60228, IEC
1KV Power XLPE Power Cable With Class 2 Compacted Round Conductor
1KV Power Cable Made By IEC 60502.1standard With Class 2 Compacted Round Conductor Conductor : Plain annealed copper solid or stranded (class 1 or 2) conductor complying with IEC 60228 Insulation : XLPE(cross-linked polyethylene) rated at 90 ℃ Sheath : PVC type ST2 , according to IEC 60502, black Note: Insulation identification as per standards or customer requirement Applications For laying indoors and outdoors. Able to bear certain traction during installation, but not
Compacted Round Conductor XLPE Power Cable Corrugated Aluminum PVC Sheathed
220kV Cross-linked polyethylene insulated corrugated aluminum sheathed PVC sheathed longitudinal water resistance cable Construction Technical data Maximum Conductor Temperature: under normal (90 ℃), emergency (130℃) or short circuit no more than 5 s (250℃) conditions. Min. Ambient Temp.: The cable shall be pre heated if the ambient temperature is below 0℃ Min. Bending Radius: 20(d+D)±5% 1. Conductor: 1.1 Compact round conductors, composed of several layers of concentric
630mm2 Cross Linked Polyethylene Cable 64/110kV Corrugated Aluminum PE Sheathed
630mm2 64/110kV Cross-linked polyethylene insulated corrugated aluminum sheathed PE sheathed power cable Construction Technical data Maximum Conductor Temperature: under normal (90 ℃), emergency (130℃) or short circuit no more than 5 s (250℃) conditions. Min. Ambient Temp.: The cable shall be pre heated if the ambient temperature is below 0℃ Min. Bending Radius: 20(d+D)±5% Certificates CE, SGS, KEMA and more others at request Ordering Advice Rated Voltage Application Standard
110kV XLPE Power Cable Metallic Screen , Cross Linked Polyethylene Wire
110kV Cross-linked polyethylene insulated corrugated aluminum sheathed PVC sheathed power cable Construction Standards International: IEC 60840 IEC 62067 China: GB∕T 11017, GB∕T 18890 Other standards such as BS,VDE and ICEA upon request 1. Conductor: 1.1 Compact round conductors, composed of several layers of concentric spiral-wound wires. 1.2 Segmental conductors, conductors are composed of several segment-shaped conductors assembled together to form a cylindrical core. 2.
Cu Conductor XLPE Power Cable , Electrical MV XLPE Cable XLPE PVC Insulation
MV Power Cable Cu Conductor 3 Cores XLPE Insulation Electrical Power Cable Detailed Product Description Ordering Advice Rated Voltage Application Standard: IEC/BS/UL/GB Number of Cores Conductor Size & Construction Type of Insulation Armored or unarmored. If armor, the armor type & material The Requirement of Sheath Length of Cable & Packing Requirement Other Requirement Technical data Rated voltage: 18/30 kV Maximum Conductor Temperature: under normal (90 ℃), emergency (130℃
Underground XLPE Power Cable 18/30KV 120mm2 Laying In Room Tunnel Pipes
18/30 (36) KV, 120 mm2 3 Cores Copper Conductor XLPE Insulated Underground Cable Detailed Product Description Construction Conductor : Compact stranded copper conductor, Cl.2 as per IEC 60228 Conductor Screen: Semi-conductor Insulation : XLPE(cross-linked polyethylene) rated at 90 ℃ Insulation Screen: Semi-conductor Screen : Copper tape Sheath : PVC type ST2 to IEC 60502, black Note: Insulation identification as per standards or customer requirement Applications Laying in
Stranded XLPE Power Cable , 185 / 300mm2 XLPE Cable CE SGS Certificated
185/300mm2 x 3 core,12/20kv,XLPE Stranded Power Cable(CU/XLPE/STA/PVC) Detailed Product Description Ordering Advice Rated Voltage Application Standard: IEC/BS/UL/GB Number of Cores Conductor Size & Construction Type of Insulation Armored or unarmored. If armor, the armor type & material The Requirement of Sheath Length of Cable & Packing Requirement Other Requirement Note: Insulation identification as per standards or customer requirement Applications 12/20kV XLPE power Cable
Copper XLPE Insulated PVC Sheathed Cable 12/20kV 50-500mm 1 Or 3 Cores
50-500mm 1 or 3 cores XLPE PVC insulated 12/20kv power cable Detailed Product Description Note: Insulation identification as per standards or customer requirement Applications 12/20kV XLPE power Cable is used indoor or outdoor, in tunnel, cable furrow or pipe, to be laid underground, be applicable to the well, water inside and fall in the bad soil. Certificates CE, SGS, KEMA and more others at request Standards International: IEC 60502, IEC 60228 China: GB/T 12706.2-2008
Multi Core XLPE Power Cable 3x95mm2 3x120mm2 3x240mm2 Copper Tape Screen
Medium Voltage 12/20kv XLPE copper tape metallic powercable with 500mm2 Detailed Product Description Standards International: IEC 60502, IEC 60228 China: GB/T 12706.2-2008 IEC60502.2 HS620 S1 Other standards such as BS,VDE and ICEA upon request Technical data Rated voltage: 12/20 kV Maximum Conductor Temperature: under normal (90 ℃), emergency (130℃) or short circuit no more than 5 s (250℃) conditions. Min. Ambient Temp.: The cable shall be pre heated if the ambient
Medium Voltage 12/20kV XLPE Power Cable 500mm2 IEC 60502-2 IEC 60228
Medium Voltage 12/20kv XLPE copper tape metallic powercable with 500mm2 Detailed Product Description Construction Conductor : Compact stranded copper conductor, Cl.2 as per IEC 60228 Conductor Screen: Semi-conductor Insulation : XLPE(cross-linked polyethylene) rated at 90 ℃ Insulation Screen: Semi-conductor Screen : Copper tape Sheath : PVC type ST2 to IEC 60502, black Note: Insulation identification as per standards or customer requirement Applications 12/20kV XLPE power
Single Phase XLPE Copper Cable Copper Tape Shield For Laying Indoors Outdoors
8.7/15kV Single Phase XLPE Insulation Cable Copper Tape Shield Electric Cable Ordering Advice Rated Voltage Application Standard: IEC/BS/UL/GB Number of Cores Conductor Size & Construction Type of Insulation Armored or unarmored. If armor, the armor type & material The Requirement of Sheath Length of Cable & Packing Requirement Other Requirement Applications For laying indoors and outdoors . Able to bear certain traction during installation , but not external mechanical
Medium Voltage XLPE Power Cable , 3 Core XLPE Unarmoured Cable Copper Tape Screen
3 core medium voltage XLPE insulated unarmored power cable with 8.7/15kV Standards International: IEC 60502, IEC 60228 China: GB/T 12706.2-2008 Other standards such as BS,VDE and ICEA upon request Construction Conductor : Compact stranded copper conductor, Cl.2 as per IEC 60228 Conductor Screen: Semi-conductor Insulation : XLPE(cross-linked polyethylene) rated at 90 ℃ Insulation Screen: Semi-conductor Screen : Copper tape Sheath : PVC type ST2 to IEC 60502, black Note:
Black Sheath 3 Core XLPE Cable Semi Conductor Insulation Screen IEC 60502.2 Standard
Three cores 6/10KV copper conductor XLPE insulation power cable Standards International: IEC 60502, IEC 60228 China: GB/T 12706.2-2008 Other standards such as BS,VDE and ICEA upon request Applications For laying indoors and outdoors . Able to bear certain traction during installation , but not external mechanical forces . Laying single core cable in magnetic ducts is not allowed. Construction 1. Conductor : Compact stranded copper conductor , Cl 2 as per IEC 60228 2.
Single Phase XLPE Power Cable PVC Jacket Copper Tape Shield Multipurpose
Single Phase XLPE Insulation Cable Copper Copper Tape Shield Electric Cable Construction 1. Conductor : Compact stranded copper conductor , Cl 2 as per IEC 60228 2. Conductor Screen : semi-conductor 3. Insulation : XLPE ( cross-linked polyethylene ) rated at 90 " C 4. Insulation Screen : semi-conductor 5. Screen : Copper tape 6. sheath : PVC or fr-pvc type ST to IEC 60502 , black Code Designation YJ : XLPE insulation V : PVC sheath ZR : Flame resistant Applications For laying
0.6/1kV XLPE Electrical Cable Class 1 / 2 Copper Conductor PP Material Filler
Xlpe Insulated Electrical Power Cable 0.6/1kv With Copper Conductor Applications For laying indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces. Laying single core cable in magnetic ducts is not allowed. Certificates CE, SGS, KEMA and more others at request Ordering Advice Rated Voltage Application Standard: IEC/BS/UL/GB Number of Cores Conductor Size & Construction Type of Insulation Armored or unarmored. If armor, the
Muti Cores XLPE PVC Cable , LV Power Cable CE IEC KEMA Certification
Muti-Cores XLPE PVC Insulated Power Cable CE IEC KEMA Certification Certificates CE, SGS, KEMA and more others at request Ordering Advice Rated Voltage Application Standard: IEC/BS/UL/GB Number of Cores Conductor Size & Construction Type of Insulation Armored or unarmored. If armor, the armor type & material The Requirement of Sheath Length of Cable & Packing Requirement Other Requirement Standards International: IEC 60502.1, IEC 60228 China: GB/T 12706.1-2008 Other standards
XLPE Insulated Low Voltage Power Cable PVC Sheath IEC60502 BS7870 Standard
LV 0.6kv / 1kv Xlpe Insulated Power Cable Pvc Sheath IEC60502 BS7870 Standard Ordering Advice Rated Voltage Application Standard: IEC/BS/UL/GB Number of Cores Conductor Size & Construction Type of Insulation Armored or unarmored. If armor, the armor type & material The Requirement of Sheath Length of Cable & Packing Requirement Other Requirement Standards International: IEC 60502.1, IEC 60228 China: GB/T 12706.1-2008 Other standards such as BS,VDE and ICEA upon request