Ultrasonic Transducer
Ultrasonic Thickness Gauge Probe 2MHz 10mm for Steel Measurement 2.0-250mm
High-precision 2MHz ultrasonic probe with 10mm crystal diameter, measuring 2.0 to 250mm thickness. Durable design for industrial use, compatible with all ultrasonic thickness gauges. Ideal for B2B quality control.
Customized Size Ultrasonic Transducer Probe DA503 2MHz 0.63 Inch Equivalent DM5E GE
High-performance ultrasonic transducer probe DA503, equivalent to DM5E of GE. Features 2MHz frequency, 0.63 inch crystal diameter, Lemo00 connector, and 5-300mm steel range. Durable, precise, and customizable for industrial NDT applications.
15 MHz TOFD Transducer Olympus Style Housing 3 mm Element NDT Flaw Detector
High-resolution 15 MHz TOFD transducer with 3 mm composite element in Olympus-style housing. Ideal for crack sizing via Time of Flight Diffraction. Offers excellent sensitivity and broadband performance for demanding NDT applications.
Replaceable USA Style Single Straight Beam BNC Probe 2.25 MHz 1 Inch Crystal
This replaceable USA style single straight beam BNC probe operates at 2.25 MHz with a 1 inch crystal. Features high sensitivity, wide bandwidth, and precise angular deviation. Ideal for industrial NDT applications. Custom options available.
USA Style Ultrasonic Contact Probe 2.25MHz 1inch Single Straight Beam BNC Probe
High-sensitivity USA style ultrasonic contact probe with 2.25MHz frequency and 1inch crystal. Features -5dB sensitivity, >45% bandwidth, and BNC connector. Ideal for industrial NDT. Custom frequencies and sizes available.
Mini Angle Beam Probe Transducer 5MHz 6x6mm High Sensitivity for Thin Materials
Mini angle beam probe transducer with 5MHz frequency and 6x6mm size. Features short 5mm approach distance for improved near-surface resolution. Ideal for thin materials and small diameter pipe welds. PEEK wedge withstands up to 248°F (120°C). Available in 45°, 60°, and 70° angles with microdot or Lemo 00 connector options.
Dual Contact Ultrasonic Transducer 2MHz 12mm for Wall Thickness Corrosion Detection
Dual element transducer designed for wall thickness and corrosion detection with excellent near surface flaw resolution. Available in 1-4MHz frequencies and 12-24mm crystal sizes. Custom options and certifications available for industrial NDT applications.
Single Element Ultrasonic Transducer DTM Delay Line Probe 2.25 MHz 1/4 Inch
High-resolution DTM delay line probe for thin material measurement and flaw detection. Features replaceable delay line, heavy damping, and contouring for curved parts. Available in 2.25 MHz and 5 MHz with Microdot connector.
Single Element Ultrasound Contact Transducer Probe 2MHz 12mm Ceramic Face with Protective Membrane
High-resolution single element straight beam contact transducer with ceramic face and protective membrane. Available in 0.5-4MHz frequencies and 12-24mm crystal sizes. Ideal for NDT applications requiring durability and sensitivity. Custom options available.
Angle Beam Ultrasonic Transducer Probe 2MHz 4MHz 8x9mm 45 60 70 Degree Top Mounted
High sensitivity angle beam ultrasonic probe with top mounted design, sensitivity better than KK 6-8dB. Bandwidth 45-55% at -6dB. Available in 2 and 4MHz, 8x9mm size, 45/60/70 degree angles. Includes maker certificate and Lemo00 equivalent connector.
TMTECK Dual Longitudinal Focus Probe 1.5MHz 10x20mm for High Noise Material NDT Welding Inspection
TMTECK dual longitudinal focus probes are specially designed for high noise material NDT industries. Features include customizable contact face for pipe radius, multiple frequency and crystal size options, and Lemo 00 connectors. Ideal for austenitic and duplex stainless steel welding inspection.
Angle Beam Probe Ultrasonic Transducer BBP 20x22mm 2MHz 4MHz 45 60 70 Degree
High sensitivity BBP angle beam probe with 45-55% bandwidth at -6dB, 6-8dB better than KK. Durable 20x22mm crystal, Lemo 00 connector. Available in 2/4MHz, 45/60/70 degree angles. Ideal for industrial NDT.
TWB Screw In 45 Degree Angle Transducer Wedge Equivalent Olympus Type 1/4
Designed for ultrasonic transducers, this 45° angle wedge enhances versatility for precise inspections. Durable construction ensures reliable performance. Compatible with Olympus type systems. Custom sizes available.
Phased Array Probe 4L16-1.0X16-M24-F2.5-D3 for Industrial NDT
High-performance phased array probe with 64 elements, 1.0 mm pitch, and 2.5 MHz frequency. Designed for precise industrial NDT. Durable, customizable, and certified for reliable inspection.
Tmteck Linear Array Probe 128 Elements Medical Ultrasound Transducer
High-resolution linear array probe with 128 elements for precise medical imaging. Durable design with 2-year warranty and lifetime repair service. Custom options available. Ideal for diagnostic ultrasound systems.
ABCT 8x9mm 2MHz 45 Degree Angle Beam Transducer High Sensitivity for GE Olympus
High sensitivity 8x9mm angle beam transducer with 45-55% bandwidth at -6dB. 6-8dB better sensitivity than KK. Lemo00 connector standard. Compatible with GE, Olympus gauges. Available in 2MHz and 4MHz with 45, 60, 70 degree angles.
Dual Armored Cable GE C123 High Temperature Probe Cable for DA590 Ultrasonic Transducer 4ft
Dual armored stainless steel jacket protects against burns and cuts. Connects DA590 high temp probe to DM5E thickness gauges. 4 feet length ensures reliable signal transmission in harsh industrial environments.
PT-08 Probe Transducer for Ultrasonic Thickness Gauge 5MHz 8mm
High-precision PT-08 probe transducer for ultrasonic thickness gauges. Features 5MHz frequency and 8mm diameter for accurate 0.8-100mm measurements. Durable design with -10 to 50°C operating range. Ideal for industrial inspection and quality control.
TM-08 Ultrasonic Probe Transducer 5MHz 8mm for Thickness Gauge 1.2-230mm Steel
High-performance TM-08 ultrasonic probe transducer with 5MHz frequency and 8mm diameter. Measures steel thickness from 1.2 to 230mm. Durable design with -10 to 60°C operating range. CE certified, ideal for industrial NDT applications. Custom options available.
DA312 Compatible 10MHz UT Probe Cable Ultrasonic Thickness Gauge 7.5mm 2xMicrodot
Equiv. GE DA312 10MHz UT probe for DMS GO thickness gauge. Features 7.5mm contact, 0.6-60mm range, dual crystal, side connection, and -20-70°C operation. Durable and precise for industrial NDT.