Edible Oil Testing Equipment
Palm oil and peanut oil detection instrument ST149 fully automatic oil oxidation stability tester
ST149 automatic plant oil oxidation stability index (OSI) is designed and manufactured in strict accordance with GB/T 21121-2007 determination of oxidation stability of animal and vegetable oils (Accelerated oxidation test). It is controlled by a single chip microcomputer and displayed by a liquid crystal LCD. The results are automatically generated and printed. ISO 6886 Oxidative Stability Test Apparatus for Animal and Vegetable Fats and Oils OSI (oxidative stability index):
Edible Oil Testing Equipment ST123A Stainless steel oil sampler made of 304 stainless steel
Product Description: ST123A plant oil sample is made of 304 stainless steel in the system, one-time maximum sampling of up to 500g. Products are suitable for grease sampling. Hot Sale Molten Metal Oil Bottom Sampler Brass/Stainless Steel Manual Asphalt Liquid Oil Sampler, Oil Sample Bottle Features: Product is simple, just at the time of sampling in the cover lines on three nylon rope, will cover the edge of the two cylinder hove tight, then slowly put the sampler into the
Essential ST110B fully automatic Lovibon colorimeter for grain and oil enterprises and testing institutions
ST110B auotomatic lovibond colorimeter is new intelligent colorimeter.It adopt RGB color recognition method. The result is display by LCD. it using the international general Lovibond color degrees as the standard, can measure various liquids, colloids, solid and powder of chroma samples. Vegetable Oil Cooking Oil Edible Oil Lovibond Tintometer Colorimeter Technical parameter: 1. measuring range: Red 0.1~79.9 Lovibond unit Yellow 0.1~79.9 Lovibond unit Blue 0.1~40 Lovibond
Abbe refractometer digital display reading, visual aiming, and temperature correction ST121C
Main uses: determination of the refractive index ND average dispersion (nF-nC) of liquid or solid and the mass fraction of dry solids in sugar and water solution, namely hammer Brix, which can be used for the detection and analysis of sugar, pharmaceutical, beverage, petroleum, food, chemical industry production, scientific research and teaching departments. Visual aiming, digital reading, temperature correction can be carried out. Main technical parameters: Measuring range
Edible Oil Testing Equipment ST121A Abbe refractometer with dedicated constant temperature device
ST121A Abbe refractometer is an instrument capable of measuring the refractive index ND and average dispersion NF-NC of transparent, translucent liquids or solids. With a thermostat connected to the instrument, it is possible to measure the refractive index ND at temperatures ranging from 0 ℃ to 70 ℃, and to measure the percentage of sugar content in the sugar solution from 0-95% (equivalent to a refractive index of 1.333-1.531). Therefore, this instrument is one of the
Automatic Vegetable Oil Oxidation Stability Tester National Standard Law Can only detect liquids
ST149 automatic plant oil oxidation stability index (OSI) is designed and manufactured in strict accordance with GB/T 21121-2007 determination of oxidation stability of animal and vegetable oils (Accelerated oxidation test). It is controlled by a single chip microcomputer and displayed by a liquid crystal LCD. The results are automatically generated and printed. ISO 6886 Oxidative Stability Test Apparatus for Animal and Vegetable Fats and Oils OSI (oxidative stability index):
ST-13Automatic potentiometric titration Determination of acid value of edible oil Automatic constant value adding liquid
The ST-13A automatic potentiometric titrator is designed in accordance with standards such as the determination of acid value in foods (GB5009.229-2016), the cold solvent automatic potentiometric titration method (the second method), and the determination of peroxide value in foods (GB5009.229-2019). The instrument uses potentiometric titration to automatically identify the titration end point and automatically calculate the results. This instrument is suitable for the
Automatic oil oxidation stability tester Both liquid and solid can be measured using the oxygen pressure change method
According to ST149B automatic oxidation stability instrument, food is kept relatively stable in a short period of time under the closed condition of room temperature and under the environment of oxygen without overpressure. When the food is heated and pressurized, the blocking effect of food on oil oxidation will be weakened. After the sample is placed in the test tank and sealed, oxygen is pumped into the test chamber and the sample is heated. Oxygen consumption is indicated
Edible Oil Testing Equipment SH110B Lovibon colorimeter has high accuracyer
ST110B auotomatic lovibond colorimeter is new intelligent colorimeter.It adopt RGB color recognition method. The result is display by LCD. it using the international general Lovibond color degrees as the standard, can measure various liquids, colloids, solid and powder of chroma samples. Vegetable Oil Cooking Oil Edible Oil Lovibond Tintometer Colorimeter Technical parameter: 1. measuring range: Red 0.1~79.9 Lovibond unit Yellow 0.1~79.9 Lovibond unit Blue 0.1~40 Lovibond
Edible Oil Testing Equipment ST149B Automatic oxidation stability tester (oxygen pressure change method)
According to ST149B automatic oxidation stability apparatus according to the food in the room temperature in a closed condition, oxygen under the environment of no overpressure in a short time to maintain a relatively stable, when the temperature increases pressure, the food itself on the oxidation of oil will be weakened. After the sample is placed in the test tank and sealed, oxygen is pumped into the test chamber and the sample is heated. Oxygen consumption is indicated by
Color LCD Screen Smoke Point Tester Dialogue Interface Meet GB / T20795 Standard
ST-123B Automatic smoke point tester is based on the national standards GB/T20795-2006 " vegetable oil smoking point tester Determination" This instrument adopts LCD screen to display .It can preset smoke point temperature and sample mark number. It has menu that can prompt and guide. It adopts simulation tracking to display the function curve of temperature rising and test time It has the functions of English operation prompt,test date,test time and other parameters. This
SH123Calibration of built-in curve for visual measurement of vegetable oil smoke point tester
ST123Oil smoke point meter is a special instrument for determining vegetable oil smoke point developed according to Article 5 "Second Method Visual Determination Method" of the national standard GB/T20795-2006 "Vegetable Oil Smoke Point Determination", which is suitable for quality supervision, import and export inspection, oil processing, oil storage and transportation, food processing, scientific research, agricultural breeding, schools and other departments that need to
GB / T20759 Edible Oil Testing Equipment For Grain And Oil Testing Center
ST-123B Automatic smoke point tester is based on the national standards GB/T20795-2006 " vegetable oil smoking point tester Determination" This instrument adopts LCD screen to display .It can preset smoke point temperature and sample mark number. It has menu that can prompt and guide. It adopts simulation tracking to display the function curve of temperature rising and test time It has the functions of English operation prompt,test date,test time and other parameters. This
High Degree Automatic Edible Oil Testing Equipment Oxidation Stability Tester oxygen pressure change method
Automatic plant oil oxidation stability instrument (oxygen pressure change method) The ST149B Automatic Oxidation Stability Tester maintains a relatively stable environment for a short period of time under an oxygen-free environment according to the food at room temperature. When the temperature and pressure are increased, the food's resistance to the oxidation of fat will be weakened. This product complies with ISO 6886: 2004 "Animal and vegetable fats and oils-Determination
Peanut Oil Edible Oil Testing Equipment Oxidative Stability Index Determination
ST149 automatic plant oil oxidation stability index (OSI) is designed and manufactured in strict accordance with GB/T 21121-2007 determination of oxidation stability of animal and vegetable oils (Accelerated oxidation test). It is controlled by a single chip microcomputer and displayed by a liquid crystal LCD. The results are automatically generated and printed. OSI (oxidative stability index): during the determination, hot air at a certain temperature is introduced into the
Automatic Plant Oil Oxidation Stability Index OSI Accordance With ISO 6886
Automatic Plant Oil Oxidation Stability Index (OSI)Accordance With ISO 6886(Accelerated Oxidation Test) ST149 automatic plant oil oxidation stability index (OSI) is designed and manufactured in strict accordance with GB/T 21121-2007 determination of oxidation stability of animal and vegetable oils (Accelerated oxidation test). It is controlled by a single chip microcomputer and displayed by a liquid crystal LCD. The results are automatically generated and printed. OSI
Abbes Refractometer ND=1.300 ~ 1.700 Refrigeration External Cycle Sugar Content 0 - 95% ST121A
ST121A Abbes Refractometer Abbes Refractometer ND=1.300 ~ 1.700 Refrigeration external cycle Sugar content 0-95% ST121A ST121A Abbe refractometer is an instrument capable of measuring the refractive index ND and the average dispersion NF-NC of transparent or semi-transparent liquids or solids. When equipped with a thermostatic device, it can determine the refractive index ND within a temperature range of 0℃ ~ 70℃ and measure the sugar concentration in a solution from 0% ~ 95%
Abbes Refractometer 0℃ ~ 70℃ Measure ND=1.3000 ~ 1.7000 Transparent And Semi Transparent Liquid ST121
ST121 Abbes refractometer Abbes refractometer 0℃ ~ 70℃ measure ND=1.3000 ~ 1.7000 Transparent and semi transparent liquid ST121 ST121 Abbe refractometer is an instrument capable of measuring the refractive index ND and average dispersion NF-NC of transparent, semi-transparent liquids or solids. When equipped with a thermostat, it can measure the refractive index ND within a temperature range of 0℃ ~ 70℃, and can also determine the percentage of sugar concentration in sugar
Particle Hardness Tester Test Travel 200mm Test Speed 0.5 ~ 500mm/Min ASTM D4179
ST120K Particle hardness tester Particle hardness tester Test travel 200mm Test speed 0.5 ~ 500mm/min ASTM D4179 Standard: GB/T 2946, HG/T2783, HG/T3927, GB/T 30202.3, GB/T 44750, ASTM D3802, ASTM D4179 ST120K hardness strength tester mainly includes a dedicated software for the main unit, spare probes, and accessories. Its basic structure generally consists of a mechanical device capable of deforming the sample, a container for holding the sample, and a recording system for
Corn Wheat Hardness Index Tester Rotor Diameter 100mm Current 2.5A power 180W ISO 20547
ST120C Wheat Hardness Index Teste Standard: GB/T 21304 ISO 20547 ICC ST120C Wheat Hardness Index Meter complies with GB/T 21304-2007 "Measurement of Wheat Hardness - Hardness Index Method." It is suitable for analyzing wheat quality in flour mills, grain storage facilities, and grain inspection departments, enabling testing and identification of wheat. It guides wheat variety selection, procurement, and trade, provides direction for specialty flour production, and measures