Circuit Breaker
AC50/60HZ GB14048.2 EA16 50KA Air Circuit Breaker
Air Circuit Breaker EcoMaster series EA16 AC50/60HZ 50KA GB14048.2 Extremely high breaking capacity—AC690V Icu is up to 50KA, the circuit breaker volume is the same as DW450-1600, and the drawer-type transmission mechanism, secondary circuit structure, operating mechanism structure, intelligent controller structure, etc. are all optimized and designed to improve reliability. Rated current:400A,630A,800A,1000A,1250A,1600A Why choose wetown: Telecommunication function. It can
50HZ EM630 630A 400V Moulded Case Circuit Breakers
EcoMaster Series Molded Case Circuit Breaker EM630 ln250-630A 400V The new EcoMaster Series Molded Case circuit breaker, with four types of frame rated current covering 10A-1000A,breaking capacity up to 100kA(Icu) 75kA (Ics), has comprehensive intelligent tripping and residual current protection products. The circuit breaker meets the following standards ● IEC60947-1 and GB 14048.1-2006 general rules for low-voltage switchgear and control equipment ● IEC60947-2 and GB 14048.2
KEMA VM3 400V 100kA 75kA 160A Mccb Circuit Breaker
VM3 Series Molded Case Circuit Breaker ln10-160A 400V The new VM3 Series Molded Case circuit breaker, with four types of frame rated current covering 10A-1000A, breaking capacity up to 100kA (Icu) 75kA (Ics), has comprehensive intelligent tripping and residual current protection products. The circuit breaker meets the following standards: ● IEC60947-1 and GB 14048.1-2006 general rules for low-voltage switchgear and control equipment ● IEC60947-2 and GB 14048.2-2008 low
T2Y 1000A KEMA IP30 ACB Low Voltage Breaker
The circuit breakers which are really suitable for wind power generation and photovoltaic power generation. It has a total of 4 frame sizes, and the rated current is up to 6,300A. The attachments of low-voltage circuit-breaker is underpressure tripper;auxiliary contact;Alarm contacts;shunt release;Electric operating mechanism, manual operating mechanism. low-voltage circuit-breaker is applicated to industrial power distribution. Why choose wetown: The plastic case is made
CQC13-462174 Intelligent 50HZ Phase Change Switch
Intelligent phase-change switch,50HZ Why choose wetown: Being equipped with remote reclosing function, the overcurrent, the overvoltage protection function at the same time; It can replace some functions of reactive compensation devices such as SVG and be used as three-phase unbalanced switching; Switching time ≤5ms; Telecommunication function. The structure is more simple and reasonable, the integration, the intelligence degree is higher, is more suitable for the
T2Y AC690V ASTA IP30 Low Voltage Air ACB Breaker
low-voltage circuit-breaker,IP30,ACB low-voltage circuit-breaker is applicated to industrial power distribution. The circuit breakers which are really suitable for wind power generation and photovoltaic power generation. It has a total of 4 frame sizes, and the rated current is up to 6,300A. The attachments of low-voltage circuit-breaker is underpressure tripper;auxiliary contact;Alarm contacts;shunt release;Electric operating mechanism, manual operating mechanism. Why choose
IP30 GB14048.1 Low Voltage AC400V Circuit Breaker
low-voltage circuit-breaker,AC400V,AC690V The attachments of low-voltage circuit-breaker is underpressure tripper;auxiliary contact;Alarm contacts;shunt release;Electric operating mechanism, manual operating mechanism. The circuit breakers which are really suitable for wind power generation and photovoltaic power generation. It has a total of 4 frame sizes, and the rated current is up to 6,300A. low-voltage circuit-breaker is applicated to industrial power distribution. Why
IEC 60947-1 GB14048.2-2008 AC690V Low Voltage Circuit Breaker
low-voltage circuit-breaker,IEC 60947-1,2;GB14048.2-2008,GB14048.1 Why choose wetown: The plastic case is made from DSM materials; The contact is made of duke contact; The arc extinguishing chamber adopts box type arc extinguishing chamber; The internal accessories adopt box type accessories for easy installation. The circuit breakers which are really suitable for wind power generation and photovoltaic power generation. It has a total of 4 frame sizes, and the rated current
KEMA ASTA VW3 60HZ 50KA 690V Air Circuit Breaker
Air Circuit Breaker EcoMaster series EA16 AC50/60HZ 50KA GB14048.2 Extremely high breaking capacity—AC690V Icu is up to 50KA, the circuit breaker volume is the same as DW450-1600, and the drawer-type transmission mechanism, secondary circuit structure, operating mechanism structure, intelligent controller structure, etc. are all optimized and designed to improve reliability. Rated current:400A,630A,800A,1000A,1250A,1600A Why choose wetown: Telecommunication function. It can
KEMA 160A 400V EM160 Molded Case Circuit Breaker
EcoMaster Series Molded Case Circuit Breaker EM160 ln10-160A 400V The new EcoMaster Series Molded Case circuit breaker, with four types of frame rated current covering 10A-1000A,breaking capacity up to 100kA(Icu) 75kA (Ics), has comprehensive intelligent tripping and residual current protection products. The circuit breaker meets the following standards: ● IEC60947-1 and GB 14048.1-2006 general rules for low-voltage switchgear and control equipment ● IEC60947-2 and GB 14048.2
KEMA AC50/60HZ EA40 GB14048.2 Air Circuit Breaker
Air Circuit Breaker EcoMaster series EA40 AC50/60HZ GB14048.2 Extremely high breaking capacity—AC400V's Icu is as high as 100KA, and the body is different from DW45 splicing type, which is a one-piece plastic compression structure, which enhances reliability and reduces temperature rise compared with similar products. Rated current:2000A,2500A,2900A,3200A,3600A,4000A Operational performance Number of operating cycles (service life) mechanical 10000 electric 400v 6000 690v
Phase Change Switch 400V 250A Intelligent Circuit Breaker
low-voltage circuit-breaker The structure is more simple and reasonable, the integration, the intelligence degree is higher, is more suitable for the processing manufacture and the mass production intelligent commutation switch. Intelligent phase-change switch is applicated to rural power distribution. Why choose wetown: It can replace some functions of reactive compensation devices such as SVG and be used as three-phase unbalanced switching; Switching time ≤5ms; Being
CQC13-462174 Intelligent Phase Change Switch 250A T2Cu Circuit Breaker
Intelligent phase-change switch,250A,T2Cu Why choose wetown: Telecommunication function. It can replace some functions of reactive compensation devices such as SVG and be used as three-phase unbalanced switching; Switching time ≤5ms; Being equipped with remote reclosing function, the overcurrent, the overvoltage protection function at the same time; The structure is more simple and reasonable, the integration, the intelligence degree is higher, is more suitable for the
WZH1-250 Intelligent Phase Change Switch 400V Circuit Breaker
Intelligent phase-change switch,400V,WZH1-250 Intelligent phase-change switch is applicated to rural power distribution. The structure is more simple and reasonable, the integration, the intelligence degree is higher, is more suitable for the processing manufacture and the mass production intelligent commutation switch. Why choose wetown: It can replace some functions of reactive compensation devices such as SVG and be used as three-phase unbalanced switching; Switching time
Intelligent CQC13-462174 Automatic Phase Changeover
Intelligent phase-change switch,CQC13-462174 Why choose wetown: It can replace some functions of reactive compensation devices such as SVG and be used as three-phase unbalanced switching; Switching time ≤5ms; Being equipped with remote reclosing function, the overcurrent, the overvoltage protection function at the same time; Telecommunication function. The structure is more simple and reasonable, the integration, the intelligence degree is higher, is more suitable for the