Patient Monitor Parts
EDAN CADENCE II Fetal Monitor TOCO and US Interface Connector Cable 01.13.104312-01 01.13.104311-01
EDAN CADENCE II Fetal Monitor TOCO and US Interface Connector Cable 01.13.104312-01 01.13.104311-01 Description US probe interface: A round interface with more contacts than TOCO, including an ultrasonic transmitter drive line, echo receiver line, shielded ground line, and probe identification line. It can withstand pulse voltages of tens or even hundreds of volts generated by the ultrasonic transmitter circuit, while also sensitively receiving echo signals at the microvolt
Edan CADENCE II Fetal Monitor Connecting Cable Between Display and Printer Board 01.13.17607
Edan CADENCE II Fetal Monitor Connecting Cable Between Display and Printer Board 01.13.17607 Description The connection cable between the display board and the printer board of the EDAN CADENCE II fetal monitor is primarily responsible for transmitting monitoring waveforms, data, and control commands to the thermal printing module, which then prints the data into reports for doctors to review. It uses a wide, flexible, flat cable with small interface spacing and metal
Edan CADENCE II Dual Fetal Monitor Connection Cable for Power Supply and Battery Board 01.13.17570
Edan CADENCE II Dual Fetal Monitor Connection Cable for Power Supply and Battery Board 01.13.17570 Description The connection between the battery pack and power board of the EDAN CADENCE II fetal monitor is primarily responsible for handling high-current charging and discharging, as well as monitoring the battery's safety status. It's not simply two positive and negative wires; it includes multiple detection lines. A crucial one is the battery temperature detection line,
EDAN Cadence II Fetal Monitor Connector Wiring Between Mainboard with Power Supply Board 01.13.17568
EDAN Cadence II Fetal Monitor Connector Wiring Between Mainboard with Power Supply Board 01.13.17568 Description The connection cable between the EDAN Cadence II fetal monitor's motherboard and power board is primarily responsible for power distribution and signal transmission. This cable harness is a combination of power and signal lines. The power lines, which deliver the main power supply, are thicker and can withstand the high current surges during printing. The signal
Edan CADENCE II Fetal Monitor Connector Cable for Power Supply Board 01.13.17551-02
Edan CADENCE II Fetal Monitor Connector Cable for Power Supply Board 01.13.17551-02 Description The power supply board connector cable of the EDAN CADENCE II fetal monitor are primarily used for energy transmission, voltage regulation, and power distribution. It is an integrated multi-output harness, including a high-voltage DC line after AC rectification, a low-voltage DC output line after transformer conversion, a battery charging control line, and a power status signal
Edan CADENCE II Fetal Monitor Grounding Wire Connecting Cable 01.13.17012 01.13.31088-01
Edan CADENCE II Fetal Monitor Grounding Wire Connecting Cable 01.13.17012 01.13.31088-01 Description These 2 connecting cables are the grounding components of the EDAN CADENCE II fetal monitor. They ensure that in the event of a leakage current, the fault current can be quickly discharged to the ground through the ground wire, guaranteeing the safe operation of the device. The cable sheath is marked with the standard yellow-green ground wire color, has a high voltage
PHiliph MX40 Touch Screen Front Pannel With Board without Speaker Models 2012 or Later
PHiliph MX40 Touch Screen Front Pannel With Board without Speaker Models 2012 or Later Product Introduction MX40 Touch Screen with Front Panel is the front-facing user interface assembly of the MX40 wearable patient monitor. This component integrates the 2.8‑inch QVGA color touch‑sensitive LCD display, the protective front housing, and the internal printed circuit board into a single replaceable assembly. The front panel features three basic function buttons located on the
COMEN STAR8000C Patient Monitor 5-Pin ECG to Power Cable 009-000661-00_A
Connection Wiring for STAR8000C COMEN STAR8000C Patient Monitor 5-Pin ECG to Power Cable 009-000661-00_A ► Brief Description This internal ECG power connector, designed specifically for the COMEN STAR8000C patient monitor, is a core precision component ensuring seamless power and signal exchange between the device's mainboard and the ECG module. Its interface size, pin definitions, and internal slots fit perfectly, allowing for seamless replacement of aging or damaged
ABS Plastic Lift Side Panel for Nihon Kohden BSM-4113K Patient Monitor, Medical Spare Parts
BSM-4113K Monitor Lift Side Panel ABS Plastic Lift Side Panel for Nihon Kohden BSM-4113K Patient Monitor ► Brief Description The Nihon Kohden BSM-4113K is a classic bedside monitor widely used in medical institutions, capable of monitoring patients' physiological parameters such as electrocardiogram, blood pressure, and blood oxygen saturation. The left panel integrates crucial power management components, serving as the first line of defense for patient and device safety. It
PHiliph Goldway CTG7 Fetal Monitor Key Membrane Original Spare Part Medical Equipment
PHiliphh Goldway CTG7 Fetal Monitor Key Membrane New Original Spare Part Medical Equipment ►Brief Description The PHiliphhGoldway CTG7 fetal monitor keyboard membrane is a flexible film that covers the monitor's keyboard. It is made of durable materials to withstand frequent use and is designed to protect the keys underneath from dust, water and other contaminants. The key membrane is made of flexible plastic and is designed with indicator buttons. This keyboard membrane is
PHiliph M3015A Module Top Cover Case M3012-44102 Measurement Server Extension Part
PHiliph M3015A Module Top Cover Case M3012-44102 Measurement Server Extension Part Brief Introduction: This top cover is an original Philiph accessory for the M3015A Patient Parameter Module, model number M3012-44102. Made of medical-grade white engineering plastic, it has a rectangular structure with positioning grooves and snap-fit interfaces for the module. Its dimensions and holes perfectly match the M3015A module's body, serving as a core external protective and
BLT Biolight Q5 Patient Monitor Module Fan 0.08A 12V AD0412MB-G70 Plastic and Metal Original Monitor Fan
BLT Biolight Q5 Patient Monitor Module Fan 0.08A 12V AD0412MB-G70 Plastic and Metal Original Monitor Fan This is the original built-in fan for the BLT Biolight Q5 patient monitor. The model number is AD0412MB-G70, with an operating current of 0.08A and a voltage of 12V. The fan has low power consumption and a compact, lightweight design, so it won't take up too much space inside the monitor. The fan casing is made of silver stainless steel, while the internal blades are made
Mindray Datascope Passport 2 Patient Monitor Comm-Port 3 Module Assembly 0998-00-0178-05
Comm-Port for Mindray Passport 2 Mindray Datascope Passport 2 Patient Monitor Comm-Port 3 Module Assembly 0998-00-0178-05 ► Brief Description The Comm-Port on the Mindray Datascope Passport 2 Patient Monitor is a communication port that enables communication with external devices such as VISA or Patient Net central stations, remote displays, gas modules, and nurse call systems. The communication port is permanently mounted in a recessed area at the bottom of the monitor. This
Biolight BLTt Q5 Patient Monitor Battery Board Q5BAT02 13-056-0010 metal material
Biolight BLTt Q5 Patient Monitor Battery Board Q5BAT02 13-056-0010 metal material ► Brief Description The Q5BAT02 Battery Board is specifically designed for the BLTt Q5 monitor. Its compact size saves internal space and features a customized connector to ensure a secure connection with the motherboard. With an input power range of 110-220V, it provides a stable power supply to the Q5 monitor. The battery board is a green metal plate with metal pin connectors for connecting to
Mindray Datascope Passport 2 Patient Monitor With Rear Cover and Handle TM 08517-L3
Mindray Datascope Passport 2 Patient Monitor With Rear Cover and Handle TM 08517-L3 Product Introduction: This is the original factory-installed back cover and handle assembly for the Mindray Datascope Passport 2 patient monitor, part number TM 08517-L33. Made of white medical-grade engineering plastic, it consists of a back cover and a handle, allowing medical staff to easily lift and quickly transport the equipment. It is ideal for scenarios involving bedside movement,
Good condition Handle for BLT Biolight Q5 Patient Monitor Used plastic Handle for repair replacement
Good condition Handle for BLT Biolight Q5 Patient Monitor Used plastic Handle for repair replacement This product is a handle for the BLT Q5 Patient Monitor, an original accessory for the Q5 monitor. The handle's main function is to facilitate transport and secure the equipment; it's a core component in the device's portable design. This handle is white and made of sturdy plastic. It's mounted directly on top of the Q5 monitor. As seen in the product image, the handle is
BLT Biolight Q5 Patient Monitor Display driver board HX-D-1 E339169 original patient monitor parts ready to ship
BLT Biolight Q5 Patient Monitor Display driver board HX-D-1 E339169 original patient monitor parts ready to ship This accessory is the display driver board for the BLT Q5, a circuit conversion board. As seen in the accessory's image, the board's model number is HX-D-1 E339169, indicating it's the original display driver board for the device. Its main function is to convert host signals into drive signals that the display screen can recognize, thus generating the parameters
SpO2 Board 9006-30-33900 For Mindray PM7000 Patient Monitor Used-good Medical Equipment Parts
SpO2 Board 9006-30-33900 for Mindray PM7000 Patient Monitor Used-goodUsed-good Mindray PM7000 SpO2 Board 9006-30-33900 ► Brief Introduction SpO2 Board 9006-30-33900 is a key component of Mindray PM7000 patient monitor, used to monitor the patient's blood oxygen saturation (SpO2) and pulse rate, provide accurate blood oxygen concentration levels, and help medical staff evaluate the patient's respiratory function and circulatory system status. Its core function is to receive
Plastic Mindray T8 Patient Monitor Handle Frame Patient Monitor Handle Frame Parts
Mindray T8 Patient Monitor Handle Frame Mindray T8 Patient Monitor Handle Frame Patient Monitor Handle Frame Parts Mindray Parts Patient Monitor Parts Mindray T8 Patient Monitor Handle Frame Brief Introduction The Mindray T8 Patient Monitor Handle Frame is a handle device used for the Mindray T8 monitor machine. This handle can usually be used to carry the monitor, making it easier for doctors to carry the monitor. Feature Machine handles for medical equipment are generally
Mindray PM8000 PM-8000 Patient Monitor Front Panel Casing With Screen
Medical Bedside Monitor Parts Mindray PM8000 PM-8000 Patient Monitor Front Panel Casing With Screen Mindray PM8000 PM-8000 Patient Monitor Front Panel Casing with Screen ► Brief Introduction The Mindray PM8000 PM-8000 Patient Monitor Front Panel Casing with Screen refers to the outer casing of the patient monitor device. It includes the front panel, which houses the screen or display of the monitor. This casing provides protection and support for the internal components of