Medical Air Flow Sensor
YJJ HAFUHT0050L4AXT MEMS Thermal Mass Flow Sensor 0-50SLPM for Medical / Industrial Applications
Product Description: YJJ HAFUHT0050L4AXT MEMS Thermal Mass Flow Sensor 0-50SLPM for Medical / Industrial Applications Features: I. Core Parameters (25℃, 1 atm) Model: HAFUHT0050L4AXT Measurement medium: Dry and clean air / Non-corrosive gas Range: 0–50 SLPM (Standard liters per minute) Accuracy: ±0.5% FS (Full Scale) Resolution: Minimum 0.002 SLPM Response time: ≤1 ms (Fast dynamic measurement) Output interface: I2C (Digital), Slave Address 0x49, 3.3V level Power supply
YJJ HAFUHH0050L4AXT MEMS Thermal Mass Flow Sensor for Medical Use 0-50SLPM
Product Description: YJJ HAFUHH0050L4AXT MEMS Thermal Mass Flow Sensor for Medical Use 0-50SLPM Features: I. Core Parameters (25℃, 1 atm) Model: HAFUHH0050L4AXT Measurement medium: Dry and clean air / Non-corrosive gas Range: 0–50 SLPM (resolution up to ±0.05 SLPM) Accuracy: ±0.5% FS (full scale), ±0.5% reading Repeatability: ±0.1% FS Response time: ≤ 1 ms (rapid dynamic measurement) Output interface: I2C (digital), 3.3V level Power supply voltage: 3–10 VDC (typical 3.3/5V)
YJJ MF5006-N2M-E-0.5-50-15-AB-D-A MEMS Thermal Gas Mass Flowmeter 0.5-50 SLPM 1.5MPa
Product Description: YJJ MF5006-N2M-E-0.5-50-15-AB-D-A MEMS Thermal Gas Mass Flowmeter 0.5 - 50 SLPM 1.5MPa Features: I. Model Disassembly (Detailed Meanings of Each Position) MF5006-N2M-E-0.5-50-15-AB-D-A MF5006: Series, DN6 (Inner Diameter 6mm, 1/4" Interface) N2: Standard Gas = Nitrogen (N₂) M: MEMS Thermal Mass Flow Principle E: Aluminum Alloy Shell 0.5: Minimum Range 0.5 SLPM (Standard Liters Per Minute at 20°C / 1 atm) 50: Maximum Range 50 SLPM 15: Maximum Working
YJJ MF2025BE-AB-A MEMS Thermal Gas Mass Flowmeter for Industrial Gas Measurement
Product Description: YJJ MF2025BE-AB-A MEMS Thermal Gas Mass Flowmeter for Industrial Gas Measurement Features: I. Model Disassembly (MF2025BE-AB-A) MF2025: Series, **DN25 (1")** diameter B: Basic type (with display) E: Aluminum alloy tube body AB: Output combination RS485 + 4-20mA A: Standard range / conventional configuration II. Core Parameters 1. Measurement Performance Measured medium: Air, nitrogen, oxygen, argon, carbon dioxide, etc. dry and clean gases Diameter: DN25
YJJ M1174442-S1 Respiratory Flow Sensor Medical Respiratory Monitoring Equipment
Product Description: YJJ M1174442-S1 Respiratory Flow Sensor Medical Respiratory Monitoring Equipment Features: M1174442-S1 Respiratory Flow Sensor | Parameters + Applications I. Basic Information Model: M1174442-S1 Type: Reusable differential pressure type respiratory flow sensor (suitable for both newborns and adults) Applicable equipment: GE 9100C Respiratory Machine (specific original accessory) II. Core Technical Parameters Measurement Principle: Differential pressure
YJJ FS7002-A FS7002-C MEMS Wind Speed /Flow Sensor 0-5m/s Equipment Cooling Ventilation Monitoring
Product Description: YJJ FS7002-A FS7002-C MEMS Wind Speed /Flow Sensor 0-5m/s for Equipment Cooling Ventilation Monitoring Features: I. Core Parameters FS7002 Model: FS7002 (standard range) Measurement medium: Clean, dry air / non-corrosive gas Wind speed range: 0–5 m/s (bidirectional) Repeatability: ±3% FS Response time: < 20 ms Output signal: Analog voltage 0.2–3.3 VDC (non-linear) Power supply: 5 VDC ±1%, working current < 10 mA, power consumption < 50 mW Operating
YJJ FS7002-B MEMS Wind Speed /Flow Sensor 0-5m/s for Equipment Cooling Ventilation Monitoring
Product Description: YJJ FS7002-B MEMS Wind Speed /Flow Sensor 0-5m/s for Equipment Cooling Ventilation Monitoring Features: I. Core Parameters (FS7002-B) Model: FS7002-B (standard range) Measurement medium: Clean, dry air / non-corrosive gas Wind speed range: 0–5 m/s (bidirectional) Repeatability: ±3% FS Response time: < 20 ms Output signal: Analog voltage 0.2–3.3 VDC (non-linear) Power supply: 5 VDC ±1%, working current < 10 mA, power consumption < 50 mW Operating
YJJ AMS2106-R00 0-25SLPM Intelligent Digital Gas Mass Flowmeter Medical Field
Product Description: YJJ AMS2106-R00 0-25SLPM Intelligent Digital Gas Mass Flowmeter Medical Field Features: I. Basic Information Brand: ASAIR (your current core domestic supplier) Model: AMS2106-R00 Principle: MEMS thermal mass flow measurement, directly measures mass flow, no need for temperature and pressure compensation R00 meaning: Basic general model, standard range, RS485-Modbus-RTU communication output Measured gases: air, nitrogen, oxygen, argon, CO₂, etc., clean and
YJJ MF4608-R2-20-V-A MEMS Micro-Electro-Mechanical Thermal Gas Mass Flow Sensor
Product Description: YJJ MF4608-R2-20-V-A MEMS Micro-Electro-Mechanical Thermal Gas Mass Flow Sensor Features: I. Basic Information Model Interpretation MF4608: MF4600 series, 0 - 20 SLPM standard range model R2: RS485 - Modbus communication 20: Range 0 - 20 SLPM (standard liters / minute) V: 0 - 5V analog voltage output A: Measured medium is air (Air) Detection Principle: MEMS micro-electromechanical thermal mass flow sensing (direct measurement of mass flow, no need for
MF5006-N2M-e-0.5-50-15-AB-D-A High-precision MEMS Thermal Gas Mass Flow Meter for Real-time Flow Monitoring
MF5006-N2M-e-0.5-50-15-AB-D-A High-precision MEMS Thermal Gas Mass Flow Meter for Real-time Flow Monitoring Product Application: MF5006-N2M-e-0.5-50-15-AB-D-A is a high-precision MEMS thermal gas mass flow meter. It is professionally calibrated for nitrogen gas, specially used for real-time flow monitoring and quantitative control of nitrogen. Widely applied in laboratory gas distribution, industrial nitrogen supply pipelines, semiconductor manufacturing, atmospheric
MF2025BE-AB-A Gas Mass Flow Meter for Accurate Flow Detection of Clean Gases Such As air Oxygennitrogen Inert Gas
MF2025BE-AB-A Gas Mass Flow Meter for Accurate Flow Detection of Clean Gases Such As air Oxygennitrogen Inert Gas Product Application:MF2025BE-AB-A is a high-precision thermal gas mass flow meter. It is specially designed for accurate flow detection of clean gases such as air, oxygen, nitrogen and inert gas. Widely applied in industrial gas monitoring, laboratory gas distribution systems, medical gas pipelines, environmental protection testing equipment and automated
M1174442-S1 High-precision Medical Differential Pressure Flow Sensor for Hospital Anesthesia Machines
M1174442-S1 High-precision Medical Differential Pressure Flow Sensor for Hospital Anesthesia Machines Product Application: M1174442-S1 is a high-precision medical differential pressure flow sensor manufactured by GE. It is specially designed for GE 9100C and ZY9100 anesthesia ventilator equipment. The sensor accurately monitors gas flow and pressure changes in the breathing circuit. It is widely used in hospital anesthesia machines, clinical ventilators and respiratory
MF5006-N2M-E-0.5-50-15-AB-D-A Gas Mass Flowmeter MEMS With LCD
MF5006-N2M-E-0.5-50-15-AB-D-A Gas Mass Flowmeter MEMS With LCD Principle:** MEMS thermal mass flow measurement; directly measures mass flow without the need for temperature or pressure compensation. Features: * High sensitivity for low-flow ranges; low pressure drop * Explosion-proof design, suitable for industrial and hazardous environments * Simultaneous analog and digital communication capabilities, facilitating network integration * Equipped with a local display for
MF2025BE-AB-A Gas Mass Flowmeter Integrated Display Thermal Mass
MF2025BE-AB-A Gas Mass Flowmeter Integrated Display Thermal Mass Working Principle and Features 1. Principle:** MEMS thermal mass flow sensing; measures mass flow directly, requiring no temperature or pressure compensation. Features: * Integrated design; compact and easy to install * Bidirectional measurement capability; excellent stability * Supports networking (RS485) and local display Typical Applications * Industrial compressed air / nitrogen / oxygen metering *
M1174442-S1 Differential Pressure Flow Sensor Respiratory Flow
M1174442-S1 Differential Pressure Flow Sensor Respiratory Flow Core Features 1. Measures bidirectional airflow (inhalation/exhalation) within the breathing circuit, and calculates tidal volume, minute ventilation, and flow waveforms. 2. Operates based on the differential pressure principle: airflow passing through a restriction orifice generates a pressure differential, which the sensor converts into an electrical signal for processing by the host unit. 3. Consists of the
FS7002-B Accurate 0.2-0.8VDC Zero Voltage Medical Air Flow Sensor with 20ms Response Time
FS7002-B Accurate 0.2-0.8VDC Zero Voltage Medical Air Flow Sensor with 20ms Response Time Features Designed for free space air mass flow speed Fast response time Compact footprint Both analog interface Large turn-down ration over 100:1 Flow switch capability Applications Free space gas flow speed measurement Filter clogging sensing Compact space flow measurement Instrumentation Wearable device applications Motor or fan monitor Specification: Flow range 0~5 Repeatability +3.0
FS1015CL-100-ISO-C Thermal gas mass Flow Sensor Interface ISO 15mm
FS1015CL-100-ISO-C Thermal gas mass Flow Sensor Interface ISO 15mm Typical Applications: 1. Ventilators/Anesthesia Machines: Oxygen, air, and CO₂ mixed gas flow monitoring 2. Endoscopes: CO₂ pneumoperitoneum flow control 3. Medical Gas Analyzers: Precise flow sampling 4. Other Clean Gases: Nitrogen, argon, etc. (calibration required) Speicification: Response Time ≤8 ms (typical) Output Signal Analog 0.5–4.5 VDC (linearly corresponding to 0–100% flow); Digital I²C Power Supply
FS1015CL-100-ISO-C MEMS Mass Flow Sensor for Medical Ventilators & Anesthesia Machines Respiratory Therapy Equipment
FS1015CL-100-ISO-C MEMS Mass Flow Sensor for Medical Ventilators & Anesthesia Machines Respiratory Therapy Equipment Applications: Medical ventilators & anesthesia machines Respiratory therapy equipment Medical gas monitoring & control Endoscopic gas flow systems Industrial clean gas flow meters Flow Range 0 ~ 100 SLPM Accuracy ±(2.0 + 0.5% FS) % Repeatability ±0.5% of reading Supply Voltage 5.0 V DC ±5% (4.75~5.25 V) Output Signal Analog linear: 0.5 ~ 4.5 V DC Response Time
YJJ AMS1000A04 Thermal Gas Mass Flow Meter MEMS Chip for Industrial Process Control - 0-200L/min
Product Description: YJJ AMS1000A04 Thermal Gas Mass Flow Meter MEMS Chip for Industrial Process Control - 0-200L/min Features: Core Parameters (AMS1000A04) Measurement Principle: Thermal Mass Flow (MEMS Chip) Detected Gases: Air, N2, O2, CO2, Ar, He, etc. - Dry, clean, non-corrosive, non-flammable, and non-explosive gases Range (A04): 0 - 200 L/min (Standard) Accuracy: ±4% RD (2 ≤ x < 50 L/min) ±2% RD (50 ≤ x ≤ 200 L/min) Repeatability: ≤ ±0.5% FS Response Time (T90): ≤ 1
YJJ FLS2101P NEWPORT(NEWPORT)E360 Outgoing Flow Sensor
Product Description: YJJ FLS2101P NEWPORT(NEWPORT)E360 Outgoing Flow Sensor Features: Introduction The e360 ventilator (Newport Medical, Costa Mesa, CA) supplies invasive or noninvasive ventilatory support and monitoring for infant, pediatric, and adult patients. Description of unique features Circuit Check ensures that intelligent breath management functions are calibrated to the installed breathing circuit system. Quick Setup (Worldwide [WW] Version) makes set up easier for