MP-3B Alcohol Gas Sensor Lower Consumption Small Size Fast Response And Resume Highest Sensitivity For Detecting Whether Ethanol Steamy Exist In Other Places
MP-3B Alcohol Gas Sensor Lower Consumption Small Size Fast Response And Resume Highest Sensitivity For Detecting Whether Ethanol Steamy Exist In Other Places MP-3B model with advanced planar construction is comprised of heater and metal oxide semiconductor material of subminiature Al2O3 ceramic plate, fetch out electrode down-lead, encapsulation in metal base and cap. When the target gas (alcohol) exists , The sensor’s conductivity is more higher along with the gas concentrat
MP-4 MP-4C Flammable Gas Sensor Lower Consumption Small Size Fast Response And Resume For Industrial Flammable Gas Alarm And Portable Gas Detector
MP-4 Flammable Gas Sensor Lower Consumption Small Size Fast Response And Resume For Industrial Flammable Gas Alarm And Portable Gas Detector MP-4 model with advanced planar construction is comprised of heater and metal oxide semiconductor material of subminiature Al2O3 ceramic plate, fetch out electrode down-lead, encapsulation in metal base and cap. When the target gas exists, the sensor’s conductivity is more higher along with the gas concentration rising. Please use simple
MP-2 Smoke Gas Sensor Good Sensitivity To LPG Smoke In Wide Range Small Size For Domestic Smoke Leakage Alarm Industrial Smoke Gas Alarm And Portable Smoke Detector
MP-2 Smoke Gas Sensor Good Sensitivity To LPG Smoke In Wide Range Small Size For Domestic Smoke Leakage Alarm Industrial Smoke Gas Alarm And Portable Smoke Detector MP-2 model with advanced planar construction is comprised of heater and metal oxide semiconductor material of subminiature Al2O3 ceramic plate, fetch out electrode down-lead, encapsulation in metal base and cap. When the target gas exists , the sensor’s conductivity is more higher along with the gas concentration
MH-Z14A MH-Z14B Intelligent Infrared Carbon Dioxide Module HVAC Refrigeration Indoor Air Quality Monitoring For Air Cleaner Device
MH-Z14A MH-Z14B Intelligent Infrared Carbon Dioxide Module HVAC Refrigeration Indoor Air Quality Monitoring For Air Cleaner Device Profile: MH-Z14A MH-Z14B NDIR Infrared gas module is a common type, small size sensor, using non-dispersive infrared (NDIR) principle to detect the existence of CO2 in the air, with good selectivity, non-oxygen dependent and long life. Built-in temperature sensor can do temperature compensation; and it has digital output and PWM output. This
MH-742B Combustible Gas Sensor High Sensitivity High Resolution Low Power Consumption High sensitivity High Resolution Low Power Consumption
MH-742B Combustible Gas Sensor High Sensitivity High Resolution Low Power Consumption High sensitivity High Resolution Low Power Consumption Product Description: MH-742B is a universal type intelligent sensor to detect combustible gas,taking advantage of non-dispersive infrared (NDIR) principle. With high selectivity, no oxygen dependence, high performance and long lifespan features, MH-742B also has built-in temperature compensation feature. MH-742B is a compact and high
MG-812 MG812 Is A Semiconductor Oxide Chemical Sensor That Uses The Principle Of A Solid Electrolyte Battery To Detect CO2
MG-812 MG812 Is A Semiconductor Oxide Chemical Sensor That Uses The Principle Of A Solid Electrolyte Battery To Detect CO2 Product description: MG-812 is a semiconductor oxide chemical sensor that uses the principle of a solid electrolyte battery to detect CO2. When the sensor is kept at a certain operating temperature and placed in a CO2 atmosphere, electrode reaction occurs in the positive and negative electrodes of the battery, electromotive force is generated between the
MEu-2O2 Oxygen Sensor Is A Fixed Potential Type Sensor Oxygen Undergoes A Reduction Reaction On The Working Electrode
MEu-2O2 Oxygen Sensor Is A Fixed Potential Type Sensor Oxygen Undergoes A Reduction Reaction On The Working Electrode Description : MEu-2O2 oxygen sensor is a fixed potential type sensor. Oxygen undergoes a reduction reaction on the working electrode, and at the same time, a corresponding oxidation reaction occurs on the counter electrode, releasing charges to form a current. The current is proportional to the oxygen concentration and follows Faraday's law. The size can
ME4-SO2-E4 Sulfur Dioxide Sensor Is A cConstant Potential Electrolytic SO2 Sensor SO2 And O2 Undergo Corresponding REDOX Reaction At The Working Electrode And The Opposite Electrode And Release Charge
ME4-SO2-E4 Sulfur Dioxide Sensor Is A cConstant Potential Electrolytic SO2 Sensor SO2 And O2 Undergo Corresponding REDOX Reaction At The Working Electrode And The Opposite Electrode And Release Charge Product description: ME4-SO2-E4 sensor is a constant potential electrolytic SO2 sensor. SO2 and O2 undergo corresponding REDOX reaction at the working electrode and the opposite electrode and release charge to form current. The concentration of SO2 is proportional to the current
ME4-NO2-E4 Outdoor NO2 Sensor The Sensor's Fourth Electrode Auxiliary Electrode Is Used To Compensate The Zero Current So That It Has A Strong Signal Level Low Zero Current Characteristics
ME4-NO2-E4 Outdoor NO2 Sensor The Sensor's Fourth Electrode Auxiliary Electrode Is Used To Compensate The Zero Current So That It Has A Strong Signal Level Low Zero Current Characteristics Product description: The ME4-NO2-E4 sensor is a constant potential electrolytic NO2 sensor. NO2 and O2 undergo corresponding REDOX reaction on the working electrode and the opposite electrode and release charge to form current. The current generated is proportional to the concentration of
ME4-NO2 Nitrogen Dioxide Gas Sensor Is Constant Potential Electrolysis Type Oxidation-reduction Reaction With Nitrogen Dioxide And Oxygen Take Place Respectively On The Working Electrode
ME4-NO2 Nitrogen Dioxide Gas Sensor Is Constant Potential Electrolysis Type Oxidation-reduction Reaction With Nitrogen Dioxide And Oxygen Take Place Respectively On The Working Electrode Profile : ME4-NO2 nitrogen dioxide gas sensor is constant potential electrolysis type. Oxidation-reduction reaction with nitrogen dioxide and oxygen take place respectively on the working electrode and on the counter electrode. The process releases electric charge and generates current. The
ME4-H2S Hydrogen Sulfide Gas Sensor Oxidation-reduction Reaction With Hydrogen Sulfide And Oxygen Take Place Respectively On The Working Electrode And On The Counter Electrode
ME4-H2S Hydrogen Sulfide Gas Sensor Oxidation-reduction Reaction With Hydrogen Sulfide And Oxygen Take Place Respectively On The Working Electrode And On The Counter Electrode ME4-H2S hydrogen sulfide gas sensor is constant potential electrolysis type. Oxidation-reduction reaction with hydrogen sulfide and oxygen take place respectively on the working electrode and on the counter electrode. The process releases electric charge and generates current. The current is in direct
YJJ 7H AC704-400 Electrochemical 7 Series Hydrogen H2 Sensor
Product Description: 7H Electrochemical 7 Series Hydrogen H2 Sensor Features: CiTiceLs may exhibit a response to certain gases in a sample other than the target gas. 7H CiTiceLs have been tested with a number of commonly cross-interfering gases and the results are given below. The table shows the typical response to be expected from a sensor when exposed to a given test gas concentration (relevant to safety, e.g. TLV levels). Every effort has been made to ensure the accuracy
ME3-SO2 Electrochemical Sensor Which Utilizes The Electrochemical Oxidation Process Of Target Gas On The Working Electrode Inside The Electrolytic Cell
ME3-SO2 Electrochemical Sensor Which Utilizes The Electrochemical Oxidation Process Of Target Gas On The Working Electrode Inside The Electrolytic Cell ME3-SO2 electrochemical sensor detect gas concentration by measuring current based on the electrochemical principle, which utilizes the electrochemical oxidation process of target gas on the working electrode inside the electrolytic cell, the current produced in electrochemical reaction of the target gas are in direct
ME3-NO2 Electrochemical Gas Sensor Detect Gas Concentration By Measuring Current Based On The Electrochemical Principle
ME3-NO2 Electrochemical Gas Sensor Detect Gas Concentration By Measuring Current Based On The Electrochemical Principle ME3-NO2 electrochemical sensor detect gas concentration by measuring current based on the electrochemical principle, which utilizes the electrochemical oxidation process of target gas on the working electrode inside the electrolytic cell, the current produced in electrochemical reaction of the target gas are in direct proportion with its concentration while
YJJ 5SF AD526-W0G Electrochemical Sulfur Dioxide SO2 Sensor
Product Description: 5SF AD526-W0G Electrochemical Sulfur Dioxide SO2 Sensor Features: CiTiceLs may exhibit a response to certain gases in a sample other than the target gas. The table below shows the typical response of 5SF sensors to a number of common cross-interfering gases. The figures are expressed as a percentage of the primary sensitivity (i.e. sulphur dioxide = 100%). Every effort has been made to ensure the accuracy of this document at the time of printing. In
YJJ 5OxLL Oxygen (O2) Gas Sensor for Emissions Part Number: AA783-33J
Product Description: 5OxLL Oxygen (O2) Gas Sensor for Emissions Part Number: AA783-33J Features: The purpose of this document is to present the performance specification of the 5OxLL longlife oxygen sensor. This document should be used in conjunction with the 4OxLL / 5OxLL (Emissions) Characterisation Note, the 4OxLL / 5OxLL Operating Principles (OP19) and the Product Safety Datasheet (PSDS 5). The data provided in this document are valid at 20°C, 50% RH and 1013 mBar for 3
YJJ Low Range NO 5NFL Nitric Oxide Sensor Product Code: AF508-W0P
Product Description: Low Range NO 5NFL Nitric Oxide Sensor Product Code: AF508-W0P Features: The purpose of this document is to present the performance specification of the 5NFL nitric oxide gas sensor. This document should be used in conjunction with Operating Principles (OP20) and the Product Safety Datasheet (PSDS 18). The data provided in this document are valid at 20°C, 50% RH and 1013 mBar for 3 months from the date of sensor manufacture. Output signal can drift below
ME3-HF Electrochemical Sensor Detect Gas Concentration By Measuring Current Based On The Electrochemical Principle
ME3-HF Electrochemical Sensor Detect Gas Concentration By Measuring Current Based On The Electrochemical Principle ME3-HF electrochemical sensor detect gas concentration by measuring current based on the electrochemical principle, which utilizes the electrochemical oxidation process of target gas on the working electrode inside the electrolytic cell, the current produced in electrochemical reaction of the target gas are in direct proportion with its concentration while
YJJ 4PH3-20 Four-Series Electrochemical Gas Sensor Phosphine Sensor CLE-1121-400
Product Description: 4PH3-20 Four-Series Electrochemical Gas Sensor Phosphine Sensor CLE-1121-400 Features: Product model CLE-1121-400 Range 0 to 20 ppm Load 100 ppmSensitivity 1.4 ± 0.6 mA/ppm Baseline (20℃)
YJJ 4NO2-20 CLE-0321-400 Nitrogen Dioxide Electrochemical Sensor
Product Description: 4NO2-20 CLE-0321-400 Nitrogen Dioxide Electrochemical Sensor Features: Performance Characteristics electrochemical gas sensor is a microfuel cell original, but it is developed on the basis of the original oxygen sensor. It has been successfully developed because of low power consumption, good selectivity, high sensitivity and low efficiency. The main design features of the electrochemical gas sensor are capillary adsorption of liquid electrolyte, small