CO-AF Carbon Monoxide Sensor Small With Filter Membrane 5000ppm For Carbon Monoxide Gas Analyzer
CO-AF Carbon Monoxide Sensor Small With Filter Membrane 5000ppm For Carbon Monoxide Gas Analyzer CROSS Filter capacity ppm·hours H2S 250,000 SENSITIVITY Filter capacity ppm-hours NO2 600,000 Filter capacity ppm-hours NO 20,000 Filter capacity ppm-hours SO2 300,000 H2S sensitivity % measured gas @ 20ppm H2S < 0.1 NO2 sensitivity % measured gas @ 10ppm NO2 < 0.1 Cl2 sensitivity % measured gas @ 10ppm Cl2 < 0.1 NO sensitivity % measured gas @ 50ppm NO < 5 SO2 sensitivity %
YJJ SO-E2-250 Limiting Current Oxygen Sensor Zirconia Oxygen Sensor Can replace SO-B0-250
Product Description: SO-E2-250 Limiting Current Oxygen Sensor Zirconia Oxygen Sensor Can replace SO-B0-250 Features: First, the limit current oxygen sensor SO-E2-250 working principle: Because the carrier of the current in the zirconia electrolyte is oxygen ions, when a voltage is applied to the zirconia electrolyzer, oxygen is pumped through the zirconia disk to the anode. If... give The cathode of the electrolytic cell is covered with a hole, and the rate of oxygen flow to
YJJ 4H2-1000 CLE-0613-400 Electrochemical Hydrogen Sensor (H2)
Product Description: 4H2-1000 CLE-0613-400 Electrochemical Hydrogen Sensor (H2) Features: Product model CLE-0613-400 Range 0 to 1000 ppm Maximum load 2000 ppm Sensitivity 0.02 ± 0.01 mA/ppm Baseline (20oC) < ± 0.2A Baseline drift is equivalent to 0 to 10 ppm (-20 oC to 50 oC) Resolution 10 ppm Response time (T90) £70 seconds linearity Long-term stability < 2% signal value/month Working condition Operating temperature -20 oC to 50 oC Operating humidity 15 to 90%RH (non
YJJ NAP-55A Small Low Power Combustible Gas Sensor Body Sensor Probe
Product Description: NAP-55A Small Low Power Combustible Gas Sensor Body Sensor Probe Features: NAP-55A is a small and low power sensor. The NAP-55A is intended for gas detection and leak testing. Compared with some products, NAP-55A has only half the weight and half the power consumption To produce lighter detectors. The following are the basic parameters, but it is recommended for civilian use. Sensor test circuit and NAP-66A like. First, small low-power gas sensor NAP-55A
YJJ ECO-SURE 2112B3000 Fire alarm Electrochemical Carbon Monoxide CO Sensor In Parking lot
Product Description: ECO-SURE 2112B3000 Fire alarm Electrochemical Carbon Monoxide CO Sensor In Parking lot Features: Carbon Monoxide CO Gas Measurement System - ECO-Sure X CO sensor with extended warranty, 4-20mA transmitter and mounting kit in aluminum housing. PG11 cable sealing sleeve. Measuring range: Standard: 0-300ppm CO. Optional: 0-500ppm CO Size: Includes 4 series sensors Part number: 2112B1013X Power supply: 24V d.c. Output: 4-20mA Carbon Monoxide The carbon
YJJ 0364-034-30049 H2 3E 4% 0–4% (100% LEL) Electrochemical Sensor H23E4% Hydrogen Sensor Hydrogen Probe
Product Description: H2 3E 4% Electrochemical Sensor H23E4% Hydrogen Sensor Hydrogen Probe Features: Sensoric H2 3E 4 % FEATURES Amperometric 3 electrode sensor cell Resistant to poison gases Good long term stability LEL detection TYPICAL APPLICATIONS Sensoric deems the data contained herein as factual, and the opinions expressed are those of qualified experts based on the results of tests conducted. The above data can not be used as a warranty provision or representation for
YJJ HCN 3E 30F 1639-231-30049 Leak Detection Portable Gold Mining Gas Sensor 0-30ppm Range
Product Description: HCN 3E 30F 1639-231-30049 Leak Detection Portable Gold Mining Gas Sensor 0-30ppm Range Features: This sensor is designed to be used in safety critical applications. To ensure that the sensor and/or instrument in which it is used, are operating properly, it is a requirement that the function of the device is confirmed by exposure to target gas (bump check) before each use of the sensor and/or instrument. Failure to carry out such tests may jeopardize the
YJJ 1LEL 75C PM989-600A-CIT Electrochemical Combustible Gas Sensor
Product Description: 1LEL 75C PM989-600A-CIT Electrochemical Combustible Gas Sensor Features: The purpose of this document is to present the performance specification of the 1 LEL 75C Combustible Gas sensor. This document should be used in conjunction with the 1 LEL 75 Characterisation Note, the Operating Principles (OP01), Instructions for Safe Use and the Product Safety Datasheet (PSDS 22). The data provided in this document are valid at 20°C, 50% rH and 1013 mBar for 3
YJJ NH3 3E 500 SE Three-Electrode Electrochemical Ammonia Sensor For Mobile And Point Measurement
Product Description: NH3 3E 500 SE Three-Electrode Electrochemical Ammonia Sensor For Mobile And Point Measurement Features: Urban Technology's ammonia (NH3) sensor uses a three-electrode electrochemical measurement method. The three-electrode ammonia gas sensor is based on the two-electrode sensor, by connecting the external voltage regulator circuit, and adding the reference electrode to stabilize the electromotive force of the induction electrode. In this way, even if the
YJJ S+VOX Oxygen Sensor For Electrochemical Ventilators
Product Description: S+VOX Oxygen Sensor For Electrochemical Ventilators Features: S+VOX is a partial pressure oxygen sensor with 0-100% linear output, ideal for ventilator applications. Fast response time, 0-100% measurement range, on-board temperature compensation, low drift. Details: Technical parameters: Output signal: 9-13mV Zero current (bias) : < 0.1% O2 T90 Response time: < 5 seconds Range: 0-100% Setting: Operating temperature range: -20°C - +50 °C Pressure range:
50CO-B4F Carbon Monoxide Sensor 4-Electrode (High Humidity) For Gas Analyzers
50CO-B4F Carbon Monoxide Sensor 4-Electrode (High Humidity) For Gas Analyzers NOTE: All sensors are tested with 47 ohm load resistor. This sensor has been designed for environments where the relative humidity is high; the sensor may not function correctly in dry environments. As applications of use are outside our control, the information provided is given without legal responsibility. Customers should test under their own conditions, to ensure that the sensors are suitable
YJJ S+4OX 2 Years Life 4 Series Electrochemical Oxygen Sensor For Stationary Oxygen Detector
Product Description: S+4OX 2 Years Life 4 Series Electrochemical Oxygen Sensor For Stationary Oxygen Detector Features: Applicable products: High quality industrial oxygen sensor, suitable for portable/fixed oxygen detector; Robust design, high reliability, high performance. Details: Technical parameters: Output signal: 0.1± 0.03mA Typical baseline range (pure air) : < 0.6%vol O2 T90 Response time: < 10sec Range: 0-25% Overload: 30% Environment: Operating temperature range:
YJJ GS+4NO2 Electrochemical Nitrogen Dioxide Gas Sensor For Industrial Waste Gas Detector
Product Description: GS+4NO2 Electrochemical Nitrogen Dioxide Gas Sensor For Industrial Waste Gas Detector Features: DDS electrochemical nitrogen dioxide sensor GS+NO2 is an industrial grade nitrogen dioxide sensor for portable/stationary gas detection, high stability, fast response and recovery time, strong polarity to adapt to the environment, cost-effective. Details: Performance parameters: Sensitivity: 600± 150 nA/ppm Typical baseline range (pure air) : ± 0.2ppm NO2
YJJ GS+4CO Electrochemical Carbon Monoxide CO Sensor For The Mining Industry Portable Detectors In The Steel Industry
Product Description: GS+4CO Electrochemical Carbon Monoxide CO Sensor For The Mining Industry Portable Detectors In The Steel Industry Features: GS+4CO sensors can be used in a variety of applications, including mining industry, steel industry portable detectors, packaged in accordance with industry standards, British original import, direct replacement of 4CF, CO-AF and so on. Details of GS+4CO sensors can be used in a variety of applications, including mining industry,
7HCN Hydrogen Cyanide (HCN) Gas Sensor Part Number: AJ702-400 Repeated Or Continuous Exposures Will Result In Significant Output Drift And Shortened Operating Life
7HCN Hydrogen Cyanide (HCN) Gas Sensor Part Number: AJ702-400 Repeated Or Continuous Exposures Will Result In Significant Output Drift And Shortened Operating Life IMPORTANT NOTE: Connection should be made via PCB sockets only. Soldering to the pins will seriously damage your sensor and invalidate the warranty. Poisoning: CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of
7H Electrochemistry Hydrogen Sulphide For Gas Analyzers 0-200ppm
7H Electrochemistry Hydrogen Sulphide For Gas Analyzers 0-200ppm Cross-sensitivity Data: CiTiceLs may exhibit a response to certain gases in a sample other than the target gas. 7H CiTiceLs have been tested with a number of commonly cross-interfering gases and the results are given below. The table shows the typical response to be expected from a sensor when exposed to a given test gas concentration (relevant to safety, e.g. TLV levels). IMPORTANT NOTE: Connection should be
7ETO-20 (PN: 055-0400-000) ELECTROCHEMICAL SENSOR 0 ~ 20 ppm For Gas Analyzers
7ETO-20 (PN: 055-0400-000) ELECTROCHEMICAL SENSOR 0 ~ 20 ppm For Gas Analyzers Product Description: This sensor is designed for the measurement of Ethylene Oxide concentration in gas phase. It can be used as the pin-to-pin replacement of the standard 7-series electrochemical Ethylene Oxide sensors made by the other manufacturers. Performance Characteristics: Nominal Range 0 ~ 20 ppm Maximum Overload 100 ppm Sensitivity (20℃) 2.25 ± 0.65 μA/ppm Response Time (T90) ≤ 120 s Zero
7E4-SO2-5 (PN: 056-0600-200) FOUR ELECTRODE SO2 SENSOR Product Is Used To Measure Concentration Of Sulfur Dioxide Gas Using Compensation Algorithm To Improve Accuracy Of Low Concentration
7E4-SO2-5 (PN: 056-0600-200) FOUR ELECTRODE SO2 SENSOR Product Is Used To Measure Concentration Of Sulfur Dioxide Gas Using Compensation Algorithm To Improve Accuracy Of Low Concentration Product Description:This 4-electrode sensor is designed for air quality monitoring to measure the low-concentration SO2 gas with ultra-high resolutions. The design optimizes the sensor sensitivity, accuracy and long-term stability and enables the sensor to detect SO2 variations at parts per
7E4-O3-5 (PN: 068-0900-200) FOUR ELECTRODE O3 SENSOR Product Is Used To Measure The Concentration Of Ozone Gas Using Four Electrode Structure Design Using Compensation Algorithm To Improve
7E4-O3-5 (PN: 068-0900-200) FOUR ELECTRODE O3 SENSOR Product Is Used To Measure The Concentration Of Ozone Gas, Using Four Electrode Structure Design, Using Compensation Algorithm To Improve Description: This 4-electrode sensor is designed for air quality monitoring to mea- sure the low-concentration O3 gas with ultra-high resolutions. The de- sign optimizes the sensor sensitivity, accuracy and long-term stability and enables the sensor to detect O3 variations at parts per
YJJ 4CL2-50 CLE-0951-400 Electrochemical Chlorine Gas Sensor Used For Chlorine Leakage Monitoring In Chemical Pharmaceutical Plants And Other Places