China M2703-67001 AVALON FETAL LAND  CARD for sale

M2703-67001 AVALON FETAL LAND CARD

Price: Negotiation, pls contact me
MOQ: 1
Delivery Time: Within 1-2 working days after the payment was confirmed

Avalon FM20 / FM30 Network Card Specifications 1. Part Information Network Card Part No.: M2703-67001 Alternative No.: 9001-18481C00A Hardware Type: Built-in PCI expansion card Applicable Models: Philip Avalon FM20 (M2702A), FM30 (M2703A) 2. Ethernet Specifications Interface: RJ45 port Speed: 10/100 Mbps auto-negotiation Network Protocol: TCP/IP (IPv4), DHCP / BOOTP Standard Compliance: IEEE P1073 Medical Information Bus (MIB) Transmission Mode: Unicast / Broadcast System

China Philip FM20 FM30 FETAL MONITOR NIBP SPO2 SOFTWARE UPGRAD for sale

Philip FM20 FM30 FETAL MONITOR NIBP SPO2 SOFTWARE UPGRAD

Price: Negotiation, pls contact me
MOQ: 1
Delivery Time: Within 1-2 working days after the payment was confirmed

Philip FM20 FM30 FETAL MONITOR NIBP SPO2 SOFTWARE UPGRAD Philip Avalon FM20 / FM30 Fetal & Maternal Monitor (English Technical Specifications) 1. General Information Item FM20 (M2702A) FM30 (M2703A) Type External fetal/maternal monitor External + internal fetal/maternal monitor Application Antenatal / intrapartum, basic monitoring Antenatal / intrapartum, complex high-risk cases Display 6.5” color TFT touchscreen 6.5” color TFT touchscreen Dimensions (W×H×D) 286 × 133 × 335

China M2735A M2724B M2736A US & TOCO Philip Fetal Probe for sale

M2735A M2724B M2736A US & TOCO Philip Fetal Probe

Price: Negotiation, pls contact me
MOQ: 1
Delivery Time: Within 1-2 working days after the payment was confirmed

Avalon FM20/FM30/FM40/FM50 M2735A M2724B M2736A US & TOCO Philip Fetal Probe 2734B:M2734-60501 M2735A:M2735-60501 M2736A:M2736-60501 1. M2734B TOCO MP Transducer Function: Uterine contraction monitoring + maternal pulse detection Part Number: M2734B / 453564435211 Connector: 8-pin D-type with red key Diameter: 83 mm Weight: Approx. 0.2 kg Ingress Protection: IP68, waterproof to 1m for 5 hours Safety Classification: Type CF, defibrillation-proof Operating Temperature: 0–40 °C

China P/N: M2703-26420 / M2703-66420 Philip Avalon FM20/FM30 Interface Board for sale

P/N: M2703-26420 / M2703-66420 Philip Avalon FM20/FM30 Interface Board

Price: Negotiation, pls contact me
MOQ: 1
Delivery Time: Within 1-2 working days after the payment was confirmed

Philip Avalon FM20/FM30 Interface Board (P/N: M2703-26420 / M2703-66420) Also known as: Connector Board / Jack Board / Adapter Board 1. Basic Information Official Part Number: M2703-26420 (also referenced as M2703-66420) Compatible Devices: Philip Avalon FM20 (M2702A), FM30 (M2703A) Fetal Monitors Function: Front-end I/O interface & signal switching board; routes transducer signals to mainboard Board Dimensions: ~190 mm × 85 mm PCB Layers: 4-layer, medical-grade FR-4 2.

China M2705-66510 /M2703-66450  Philip  FM20 FM30 FETAL MONITOR MAINBOARD for sale

M2705-66510 /M2703-66450 Philip FM20 FM30 FETAL MONITOR MAINBOARD

Price: Negotiation, pls contact me
MOQ: 1
Delivery Time: Within 1-2 working days after the payment was confirmed

M2705-66510 /M2703-66450 Philip FM20 FM30 FETAL MONITOR MAINBOARD 1. Main CPU Board (Mainboard Core) Part Number: M2703-66450 (also referenced as M2705-66510) CPU Core: 32-bit embedded RISC processor (medical-grade, real-time OS) Clock Speed: 200 MHz (typical) Memory: Flash: 128 MB (firmware, calibration, user presets) RAM: 64 MB (real-time data, waveforms, trend buffers) Data Storage: 72-hour fetal/maternal trend data; 800 NIBP records Embedded OS: Philip proprietary real

China Philip Avalon FM20 / FM30 Thermal Printhead (TLPH) for sale

Philip Avalon FM20 / FM30 Thermal Printhead (TLPH)

Price: Negotiation, pls contact me
MOQ: 1
Delivery Time: Within 1-2 working days after the payment was confirmed

Philip Avalon FM20 / FM30 Thermal Printhead (TLPH) (Original Philip, for M2702A / M2703A) 1. Basic Information Official Name: Thermal Line Printhead (TLPH) Compatible Models: Avalon FM20, FM30 (M2702A, M2703A) Printer Type: 6-inch thermal array recorder Part Number (Original): 4522 991 25291 (assembly) 2. Optical / Printing Resolution Dot Density: 8 dots/mm (203.2 dpi) Effective Print Width: 150 mm (full paper width) Total Dots: 1200 dots (150 mm × 8 dots/mm) Dot Pitch: 0.125

China Philip Goldway CTG7 fetal monitor for sale

Philip Goldway CTG7 fetal monitor

Price: Negotiation, pls contact me
MOQ: 1PCS
Delivery Time: Within 1-2 working days after the payment was confirmed

Philip Goldway CTG7 fetal monitor 1. General Information Model: Philip Goldway CTG7 Device Type: Combined fetal and maternal monitor Display: 7-inch TFT color LCD, 800×480 WVGA, 0–90° adjustable angle Operation: Navigation knob + backlit keys, integrated probe holder & carry handle Recorder: 150 mm width thermal printer; paper speed: 1 / 2 / 3 cm/min Data Storage: 72-hour trend review and printing; 800 sets of NIBP data storage Twin Pregnancy: Optional twin monitoring with

China PN:451261010401 / M2703-60004 Philip Avalon FM20 / FM30 Fetal Monitor – Recorder Stepper Motor for sale

PN:451261010401 / M2703-60004 Philip Avalon FM20 / FM30 Fetal Monitor – Recorder Stepper Motor

Price: Negotiation, pls contact me
MOQ: 1
Delivery Time: Within 1-2 working days after the payment was confirmed

PN:451261010401 / M2703-60004 Philip Avalon FM20 / FM30 Fetal Monitor – Recorder Stepper Motor 2. Electrical & Mechanical Specifications Motor Type: 2-phase, 4-wire stepper motor Operating Voltage: DC 12 V (internal monitor supply) Gear Ratio: 5:1 (N37 gearbox) Step Angle: 7.5°/step (after gear reduction: 1.5°/step) Rated Current/Phase: 0.67 A Phase Resistance: 5.6 Ω Phase Inductance: 4.2 mH Holding Torque: 8.3 kg-cm (≈0.81 N·m) Output Shaft: D-shaft (fits paper roller) No

China PN:453564150521 FM20 FM30 LCD SCREEN PART for sale

PN:453564150521 FM20 FM30 LCD SCREEN PART

Price: Negotiation, pls contact me
MOQ: 1
Delivery Time: Within 1-2 working days after the payment was confirmed

PN:453564150521 FM20 FM30 LCD SCREEN PART Basic Information Touch Screen: 4‑wire resistive touch panel Integrated Parts: LCD panel + touchscreen + backlight inverter + display adapter board (M2703‑66440) Main Connection: 50‑pin ribbon cable to recorder adapter board (M2703‑66430) Interface: 5‑wire touch connector; standard power/signal cables Mounting: Original housing fit, direct replacement Functions Primary user interface for FM20/FM30 Displays fetal/maternal vital signs,

China philip FM20 LCD COMPLETE PART M2703‑64503 PN 453564150521 for sale

philip FM20 LCD COMPLETE PART M2703‑64503 PN 453564150521

Price: Negotiation, pls contact me
MOQ: 1
Delivery Time: Within 1-2 working days after the payment was confirmed

Philip FM20 LCD COMPLETE PART M2703‑64503 PN:453564150521 1. OEM Part Numbers & Compatibility OEM Display Assembly Part Numbers: Standard non-touch: M2703‑64503 Capacitive touchscreen version: 453564150521 Compatible Monitors: Philip Avalon FM20, FM30 Fetal Monitors Type: 6.5-inch TFT Color LCD Display Module, foldable/tiltable mount, wide‑viewing angle design 2. Core Display Specifications Screen Size: 6.5 inches (diagonal, 16.51 cm), 4:3 standard medical aspect ratio

China Philip FM20 FM30 PN M2703 Fetal Land Card Good Condition for sale

Philip FM20 FM30 PN M2703 Fetal Land Card Good Condition

Price: Negotiation, pls contact me
MOQ: 1
Delivery Time: Within 1-2 working days after the payment was confirmed

Philip Avalon FM20 / FM30 Fetal Monitor Network Card (LAN Interface) Parameters Basic Information Model: Philip Avalon FM20 (M2702A), FM30 (M2703A) LAN Interface Type: Optional integrated LAN/RS232 system interface module (Option J70, Part No. M2703-67501) Interface Standard: 10BASE-T Ethernet (IEEE 802.3) Speed & Duplex: 10 Mbps, Half-Duplex only (no auto-negotiation, no 100 Mbps support) Port: RJ45 female connector (rear panel) Network Configuration IP Address Assignment:

China Fetal FM SERIES M2734B TOCO PROBE ORIGINAL NEW for sale

Fetal FM SERIES M2734B TOCO PROBE ORIGINAL NEW

Price: Negotiation, pls contact me
MOQ: 1
Delivery Time: Within 3 working days after the payment was confirmed

Philip M2734B TOCO MP Transducer (TOCO Probe) – Full English Specifications Basic Information Model: M2734B (Avalon TOCO MP Transducer) Type: Fetal TOCO (Tocodynamometer) + Maternal Pulse Transducer (Wired) Manufacturer: Philip Healthcare Part Number: HC989803170601 Compatibility: Philip Avalon FM20, FM30, FM40, FM50 Fetal Monitors; IntelliSpace Perinatal Systems Certifications: CE, FDA, ISO 13485 Latex‑Free: Yes Core Measurement Parameters Uterine Contraction (TOCO)

China Wireless Medical Ultrasound Probe 866075 For FM20 FM30 Fetal Monitoring for sale

Wireless Medical Ultrasound Probe 866075 For FM20 FM30 Fetal Monitoring

Price: Negotiation, pls contact me
MOQ: 1
Delivery Time: Within 3 working days after the payment was confirmed

TOCO+ MP Philip Avalon FM20 FM30 Fetal Monitor Wireless Fetal Monitoring Probe REF 866075 Descripition: Philip Avalon FM20 FM30 Fetal Monitor Wireless Fetal Monitoring Probe TOCO+ MP REF 866075 Philip Avalon FM20 FM30 Fetal Monitor Repair parts in stock:Motherboard, printhead, display, M2734B, M2736A, M2735A, TOCO+ MP, marker, cable, etc. Monitoring maintenance: Service brand: GE,PHILIP,Mindray,,TYCO,etc. Maintenance type:Electrocardiograph monitor, defibrillator, oximeter,

China Philip Patient Monitor Parts Printer Motor For FM20 FM30 Fetal Monitors for sale

Philip Patient Monitor Parts Printer Motor For FM20 FM30 Fetal Monitors

Price: Negotiation, pls contact me
MOQ: 1
Delivery Time: Within 3 working days after the payment was confirmed

Description:Philip Patient Monitor FM20 /FM30 fetal monitors utilize printer motor Monitoring maintenance Project advantages: 1. professional chip Engineer - with more than 15 years of field maintenance experience. 2.There are enough market mainstream brand type monitoring equipment maintenance accessories to send spare machine. 3. More than 90% of failures (software and hardware) of MP series monitor modules have been solved, and more than 600 M3001A modules are maintained