Medical Sterilizer
Horizontal Cylindrical High Pressure Sterilizer
Horizontal Cylindrical High Pressure Sterilizer BR-150YDA Valid volume:150L(φ440*1000mm) Max. working pressure:0.23Mpa Max.working temperature:134℃ Adjustment of temperature:40-134℃ Timer: 0-99min Or 0~60mins Heat average: ≤±2℃ Power:9kw/AC380V.50Hz Company Profile FAQ 1. who are we? We are based in Guangdong, China, start from 2017,sell to Mid East(30.00%),Africa(25.00%),South America(20.00%),Eastern Europe(10.00%),North America(5.00%),Central America(4.00%),Eastern Asia(3
Vertical Digital Automation High Pressure Steam Steilizer
Vertical Digital Automation High Pressure Steam Steilizer BR-35HD Valid volume:35L(φ318*450mm) Max. working pressure:0.23Mpa Max.working temperature:134℃ Adjustment of temperature:105-134℃ Timer: 0-99min Or 0~99hours59mins Heat average: ≤±1℃ Power:2.5kw/AC220V.50Hz (AC110V 60Hz) Company Profile FAQ 1. who are we? We are based in Guangdong, China, start from 2017,sell to Mid East(30.00%),Africa(25.00%),South America(20.00%),Eastern Europe(10.00%),North America(5.00%),Central
Hospital Dental Clinic School Use Medical Autocalve Fully Automatic Microcomputer Type Table top steam sterilizer
Table top steam sterilizer BR-AC20/24/35/50D Valid volume:20L(φ250*420mm) Power:1.5kw/AC220V.50Hz (AC110V 60Hz) Sterilizing plate:340*200*30mm(3piece) Max. working pressure:0.23Mpa Max.working temperature:134℃ Adjustment of temperature:105-134℃ Timer: 0-99min Heat average: ≤±1℃ Valid volume:24L(φ250*520mm) Power:1.5kw/AC220V.50Hz (AC110V 60Hz) Sterilizing plate:400*200*30mm(3piece) Valid volume:35L(φ300*500mm) Power:2.7kw/AC220V.50Hz (AC110V 60Hz) Sterilizing plate:400*200
Vertical Digital Automation High Pressure Steam Steilizer
Vertical Digital Automation High Pressure Steam Steilizer BR-35LD Valid volume:35L(φ318*450mm) Max. working pressure:0.23Mpa Max.working temperature:134℃ Adjustment of temperature:105-134℃ Timer: 0-99min Heat average: ≤±1℃ Power:2.5kw/AC220V.50Hz (AC110V 60Hz) Company Profile FAQ 1. who are we? We are based in Guangdong, China, start from 2017,sell to Mid East(30.00%),Africa(25.00%),South America(20.00%),Eastern Europe(10.00%),North America(5.00%),Central America(4.00%)
Hospital Dental Clinic School Use Medical Autocalve N Class Table Top Steam Sterilizer
N class Table top steam sterilizer BR-JC16/18/23 Valid volume: 16L(φ360*230mm)/18L(φ355*250mm)/23L(φ450*250mm) Max. working pressure:0.23Mpa Max.working temperature:134℃ Adjustment of temperature:105-134℃ Timer: 0-60min Heat average: ≤±1℃ Power:1.5kw/AC220V.50Hz (AC110V 50Hz) Sterilizing plate:300*200*30mm(3piece) Company Profile FAQ 1. who are we? We are based in Guangdong, China, start from 2017,sell to Mid East(30.00%),Africa(25.00%),South America(20.00%),Eastern Europe(10
Electric Or LNG Heated Sterilizer Autoclave
Electric Or LNG Heated Sterilizer BR-18LM/BR-24LM Company Profile FAQ 1. who are we? We are based in Guangdong, China, start from 2017,sell to Mid East(30.00%),Africa(25.00%),South America(20.00%),Eastern Europe(10.00%),North America(5.00%),Central America(4.00%),Eastern Asia(3.00%),South Asia(3.00%). There are total about 11-50 people in our office. 2. how can we guarantee quality? Always a pre-production sample before mass production; Always final Inspection before shipment
Table top 3 times vacuume sterilizer
Table top 3 times vacuume sterilizer BR-AC12DL 12L ◎European Class B and S, in accordance with EN 13060: 2004 standard, with three times pre-vacuum and one times pre-vacuum, pulse drying function. Vacuum index up to -0.85bar, the device residual humidity
Hospital Dental Clinic School Use Medical Autocalve High Pressure Steam Sterilizer
High Pressure Steam Sterilizer BR-18HDD/BR-24HDD Company Profile FAQ 1. who are we? We are based in Guangdong, China, start from 2017,sell to Mid East(30.00%),Africa(25.00%),South America(20.00%),Eastern Europe(10.00%),North America(5.00%),Central America(4.00%),Eastern Asia(3.00%),South Asia(3.00%). There are total about 11-50 people in our office. 2. how can we guarantee quality? Always a pre-production sample before mass production; Always final Inspection before shipment;
Medical AutocalveMirco Computer Controlled Digital Display B Class Pulse Vacuum
Mirco computer controlled Digital display B class pulse vacuum BR-AC35HV BR-AC50HV BR-AC75HV BR-AC100HV Valid volume:35L(φ340*550mm) Max. working pressure:0.23Mpa Max.working temperature:134℃ Adjustment of temperature:0-134℃ Timer: 0-99min Heat average: ≤±1℃ Power:3.0kw/AC220V.50Hz (AC110V 60Hz) Valid volume:50L(φ400*600mm) Power:3.0kw/AC220V.50Hz (AC110V 60Hz) Valid volume:75L(φ440*650mm) Power:4.5kw/AC220V.50Hz (AC110V 60Hz) Valid volume:100L(φφ440*650mm) Power:4.5kw/AC220V
Hospital Dental Clinic School Use Medical Autocalve Fully Automatic Microcomputer Type Vacuume Desktop High Pressure Steam Sterilizer B Class
Vacuume Desktop High Pressure Steam Sterilizer B Class BR-AC20/24/35/50V Valid volume:20L(φ250*360mm) Max. working pressure:0.23Mpa Max.working temperature:134℃ Adjustment of temperature:105-134℃ Timer: 0-60min Heat average: ≤±1℃ Power:1.5kw/AC220V.50Hz (AC110V 50Hz) Sterilizing plate:500*250*30mm(4 pieces) Company Profile FAQ 1. who are we? We are based in Guangdong, China, start from 2017,sell to Mid East(30.00%),Africa(25.00%),South America(20.00%),Eastern Europe(10.00%)
Horizontal Cylindrical High Pressure Sterilizer Microcomputer Controlled
Horizontal Cylindrical High Pressure Sterilizer Microcomputer Controlled BR-150YDB BR-200YDB BR-280YDB Company Profile FAQ 1. who are we? We are based in Guangdong, China, start from 2017,sell to Mid East(30.00%),Africa(25.00%),South America(20.00%),Eastern Europe(10.00%),North America(5.00%),Central America(4.00%),Eastern Asia(3.00%),South Asia(3.00%). There are total about 11-50 people in our office. 2. how can we guarantee quality? Always a pre-production sample before
Medical Autocalve Electric High Pressure Sterilizer
Electric High Pressure Sterilizer BR-18LD/BR-24LD Company Profile FAQ 1. who are we? We are based in Guangdong, China, start from 2017,sell to Mid East(30.00%),Africa(25.00%),South America(20.00%),Eastern Europe(10.00%),North America(5.00%),Central America(4.00%),Eastern Asia(3.00%),South Asia(3.00%). There are total about 11-50 people in our office. 2. how can we guarantee quality? Always a pre-production sample before mass production; Always final Inspection before shipment
Vertical Digital Fully Automatic Mirco Computer Contolled Pressure Steam Steilizer
Vertical Digital Fully Automatic Mirco Computer contolled Pressure Steam Steilizer BR-35HG BR-50HG BR-75HG BR-100HG Valid volume:35L(φ318*450mm) Max. working pressure:0.23Mpa Max.working temperature:134℃ Adjustment of temperature:0-134℃ Timer: 0-99min Or 0~99hours59mins Heat average: ≤±1℃ Power:2.5kw/AC220V.50Hz (AC110V 60Hz) Valid volume:50L(φ340*550mm) Power:3kw/AC220V.50Hz (AC110V 60Hz) Valid volume:75L(φ400*600mm) Power:4.5kw/AC220V.50Hz (AC110V 60Hz) Valid volume:100L(
Hospital Dental Clinic School Use Medical Autocalve Table Top Steam Sterilizer
Table top steam sterilizer BR-AD20/24/35/50J Valid volume:20L(φ250*420mm) Max. working pressure:0.23Mpa Max.working temperature:134℃ Adjustment of temperature:105-134℃ Timer: 0-60min Heat average: ≤±1℃ Power:1.5kw/AC220V.50Hz (AC110V 50Hz) Sterilizing plate:340*200*30mm(3piece) Valid volume:24L(φ250*520mm) Power:1.5kw/AC220V.50Hz (AC110V 50Hz) Sterilizing plate:400*200*30mm(3 pieces) Valid volume:35L(φ300*500mm) Power:1.5kw/AC220V.50Hz (AC110V 50Hz) Sterilizing plate:400*200
Hospital Dental Clinic School Use Medical Autocalve Table Top Steam Sterilizer
Table top steam sterilizer BR-AC20J/BR-AC24J Valid volume: 20L(φ250*420mm)/24L(φ250*520mm) Max. working pressure:0.23Mpa Max.working temperature:134℃ Adjustment of temperature:105-134℃ Timer: 0-60min Heat average: ≤±1℃ Power:1.5kw/AC220V.50Hz (AC110V 50Hz) Sterilizing plate: 340*200*30mm(3piece)/400*200*30mm(3 pieces) Company Profile FAQ 1. who are we? We are based in Guangdong, China, start from 2017,sell to Mid East(30.00%),Africa(25.00%),South America(20.00%),Eastern
Vertical pressure steam sterilizer
ELECTRIC-HEATED VERTICAL STEAM STERILIZER (Fully automatic microcomputer) Characteristics: 1.Fully stainless steel structure 2.Hand wheel type of quick-open door structure 3.Door safety lock system 4.Automatically controlled by computer 5.Digital display of working status,touch of key 6.Over temperature&over pressure auto-protection 7.Steam-water inner circulation system:no steam discharge,and the environment for sterilizing will be clean and dry 8.Self-inflating type seal 9
Vertical pressure steam sterilizer
VERTICAL PRESSURE STEAM STERILIZER (Digital Display Automation ) Characteristics: Fully stainless high-alloy steel structure Digital display of working status, touch of key Manual or semi-automatic control Auto discharge the cool air, and steam discharging automatically after sterilization Automatically shut off with beep reminding after sterilization The accident protection system Automatic off of heating elements at reducing of a water level Blocking top cover at working
Vertical pressure steam sterilizer
VERTICAL PRESSURE STEAM STERILIZER (Digital Display Automation ) Characteristics: l .Fully stainless steel structure 2.Hand wheel type of quick-open door structure 3.Door safety lock system 4.LCD digital display of working status,touch of key 5.Auto discharge the cool air,and steam discharging auto matically after sterilization 6.Over temperature&over pressure auto-protection 7.Safe protection of water lacking 8.Self-inflating type seal 9.Automatically shut off with beep
Table top steam sterilizer
TABLE TOP STEAM STERILIZER Characteristics: 1.Sterilizing course: Automatic sterilization controlled by computer, easy to operate. 2.Maximum temperature: up to 134 ℃, suit for 4-6 minutes rapidly sterilizing. 3.Safe protection of water lacking. 4.With over-temperature, over-pressure auto-protect device: 5.After sterilization it will automatically cut the power and then alarm. 6.Fully stainless steel structure. Technical data: MODEL TECHNICAL DATA BT-T24J Sterilizing chamber
Table top steam sterilizer
TABLE TOP STEAM STERILIZER fully automatic microcomputer type Characteristics: 1.For 4~6 minutes rapidly sterilizing. 2.Digital display of working status,touch type key. 3.With 3 fixed cycles of water adding,temperature rising,sterilizing,drying steam discharging controlled automatically. 4.The whole process of water adding,temperature rising,sterilizing,drying steam discharging controlled automatically. 4.Steam-water inner circulation system:no steam discharge,and the