Flexible Endoscope Parts
Flexible Endoscope Parts Olympus MB-155 Leakage Tester
Olympus MB-155 Leakage Tester ► Brief Description The Olympus MB-155 Leakage Tester is a critical accessory in the proper reprocessing of Olympus flexible endoscopes. It is used to ensure the integrity of the endoscope's outer sheath and internal channels, preventing costly fluid invasion and potential damage and ensuring the functionality and safety of Olympus flexible endoscopes. ► Features Early Detection of Pinhole Leaks and Loose Joints Protection Against Fluid Invasion
Olympus MH-264 SD electrosurgical handle for Surgical Procedures
Olympus MH-264 SD electrosurgical handle ► Brief Description The Olympus MH-264 SD Handle is a reusable electrosurgical handle designed for use in endoscopic procedures, primarily with polypectomy snares and hot biopsy forceps.The MH-264 SD Handle allows clinicians to manipulate the snare wire or biopsy forceps and apply electrosurgical energy to remove polyps or obtain tissue samples. It's often used with an outer plastic sheath that combines with the snare wire to form a
OLYMPUS MAJ-1154 Video cable PIGTAIL CABLE for CV-260
OLYMPUS MAJ-1154 Video cable PIGTAIL CABLE for CV-260 ► Brief Description The Olympus MAJ-1154 Video Cable (Pigtail Cable) is a crucial accessory in Olympus endoscopy systems, specifically designed to connect certain video endoscopes to their compatible video processors. It is an indispensable connecting component that ensures the seamless transmission of video and control signals, enabling the proper functioning of specific Olympus video endoscopy systems for diagnostic and
CCD driver board for PENTAX EC-3890I Colonoscope
CCD driver board for PENTAX EC-3890I Colonoscope ► Brief Description The PENTAX EC-3890I is a high-definition (HD) video colonoscope, a sophisticated medical instrument used for examining the large intestine. Like other video endoscopes, it relies on a CCD (Charge-Coupled Device) sensor at its distal tip to capture images. The CCD driver board is the essential electronic component responsible for controlling this CCD and converting the light signals into digital image data. ►
CCD Objective lens for Olympus GIF-H260 gastroscope
CCD Objective lens for Olympus GIF-H260 gastroscope ► Brief Description The objective lens system in the Olympus GIF-H260 gastroscope is a sophisticated optical component located at the very tip of the endoscope. It works in conjunction with the CCD (Charge-Coupled Device) sensor to capture high-quality images of the upper digestive tract. ► Features Light Gathering and Focusing High-Resolution Image Capture Detailed Visualization Accurate Diagnosis Comprehensive Field of
Insert Tube For OLYMPUS EXERA BF-1T160 VIDEO BRONCHOSCOPE
Insert tube for OLYMPUS EXERA BF-1T160 VIDEO BRONCHOSCOPE ► Brief Description The Olympus BF-1T160 is a video bronchoscope designed for both diagnostic and therapeutic procedures within the tracheobronchial tree.The insertion tube of the Olympus BF-1T160 bronchoscope is a critical component that houses the various elements necessary for diagnostic and therapeutic procedures within the patient's airways. It's designed for flexibility, maneuverability, and durability. ►
Light guide bundles for OLYMPUS CF-240I colonoscope
Light guide bundles for OLYMPUS CF-240I colonoscope ► Brief Description In an Olympus CF-240I colonoscope, the light guide bundle is a critical component responsible for transmitting light from an external light source to the distal tip of the endoscope. Without a functional light guide bundle, the physician would have no illumination to visualize the colon during a procedure. ► Features Light Transmission: Its primary function is to efficiently transmit intense light from
Bending Section Assembly For PENTAX EC34-i10L Colonoscope
Bending Section Assembly For PENTAX EC34-i10L Colonoscope ► Brief Description The Pentax EC34-i10L Bending Section assembly included bending section, mesh, angulation wire, coil pipe (helix tube). ► Features Compatibility: Designed for Pentax colonoscopes or similar endoscope models . Function: Replacement. Material: Stainless Steel materials for durability and sterility. Application: Used in gastrointestinal (GI) endoscopy, bronchoscopy, or hysteroscopy procedures. ►
Bending Section Assembly For PENTAX EC-3890Li Colonoscope
Bending Section Assembly For PENTAX EC-3890Li Colonoscope ► Brief Description The Pentax EC-3890Li Bending Section assembly included bending section, mesh, angulation wire, coil pipe (helix tube). ► Features Compatibility: Designed for Pentax colonoscopes or similar endoscope models . Function: Replacement. Material: Stainless Steel materials for durability and sterility. Application: Used in gastrointestinal (GI) endoscopy, bronchoscopy, or hysteroscopy procedures. ►
Insertion Tube For OLYMPUS CYF-5A Colonoscope
Insertion Tube For Olympus CYF-5A Colonoscope ► Brief Description The insertion tube for the Olympus CYF-5A colonoscope is a critical component designed for flexibility, durability, and precise control during endoscopic procedures . ► Features Compatibility: Specifically designed for the Olympus CYF-5A colonoscope model. Material: Made of high-quality, medical-grade materials for flexibility and patient safety. Length & Diameter: Optimized for colonoscopy (exact dimensions
Light Bundle For Olympus BF-H290 Bronchoscope Parts
Light Bundle For Olympus BF-H290 Bronchoscope Parts ► Brief Description The light bundle (also known as the light guide bundle or light guide fibers) of the Olympus BF-H290 is a crucial component that provides illumination for visualizing internal structures during an endoscopic examination. ► Features Illumination of the Internal Cavity Enhanced Illumination and Shadow Reduction (Dual Light Guides) Support for NBI (Narrow Band Imaging) Flexibility and Maneuverability
Insertion Tube For OLYMPUS BF-H290 Bronchoscope
Insertion Tube For Olympus BF-H290 Brochoscope ► Brief Description The BF-H290 Brochoscope Insertion Tube for replacement parts, it is Compatible new with perfect quality. ► Features Diameter: 4.0 mm (slim profile for improved patient comfort and access to narrower airways). Length: 600 mm (standard working length for bronchoscopy). Bending Angle: Upward: 180° Downward: 130° (improved maneuverability for navigation). Channel Size: 2.0 mm (allows for suction, biopsy tools, and
Bending Section Assy For PENTAX EG27‑i10 Video Gastroscope
Bending Section Assy For PENTAX EG27-i10 Video Gastroscope ► Brief Description The Pentax EG27-i10 Bending Section assembly included bending section, mesh, angulation wire, coil pipe (helix tube). ► Features Compatibility: Designed for Pentax colonoscopes or similar endoscope models. Function: Replacement. Material: Stainless Steel materials for durability and sterility. Application: Used in gastrointestinal (GI) endoscopy, bronchoscopy, or hysteroscopy procedures. ►
Bending Section Assy For PENTAX EC-3890Fi Colonoscope
Bending Section Assy For PENTAX EC-3890Fi Colonoscope ► Brief Description The Pentax EC-3890Fi Bending Section assembly included bending section, mesh, angulation wire, coil pipe (helix tube). ► Features Compatibility: Designed for Pentax colonoscopes or similar endoscope models. Function: Replacement. Material: Stainless Steel materials for durability and sterility. Application: Used in gastrointestinal (GI) endoscopy, bronchoscopy, or hysteroscopy procedures. ► Replacement
Bending Section Assy For OLYMPUS CF-Q260AL Colonoscope
Bending Section Assy For OLYMPUS CF-Q260AL Colonoscope ► Brief Description The Olympus CF-Q260AL Bending Section assembly included bending section, mesh, angulation wire, coil pipe (helix tube). ► Features Compatibility: Designed for Olympus gastroscopes or similar endoscope models . Function: Replacement. Material: Stainless Steel materials for durability and sterility. Application: Used in gastrointestinal (GI) endoscopy, bronchoscopy, or hysteroscopy procedures. ►
Bending Section Assy For OLYMPUS GIF-Q180 Endoscope Parts
Bending Section Assy For Olympus GIF-Q180 Endoscope Parts ► Brief Description The Olympus GIF-Q180 Bending Section assembly included bending section, mesh, angulation wire, coil pipe (helix tube). ► Features Compatibility: Designed for Olympus gastroscopes or similar endoscope models . Function: Replacement. Material: Stainless Steel materials for durability and sterility. Application: Used in gastrointestinal (GI) endoscopy, bronchoscopy, or hysteroscopy procedures. ►
Light Bundle For Olympus BF-1T180 Bronchoscope Parts
Light Bundle For Olympus BF-1T180 Bronchoscope Parts ► Brief Description The light bundle (also known as the light guide bundle or light guide fibers) of the Olympus BF-1T180 is a crucial component that provides illumination for visualizing internal structures during an endoscopic examination. ► Features Illumination of the Internal Cavity Enhanced Illumination and Shadow Reduction (Dual Light Guides) Support for NBI (Narrow Band Imaging) Flexibility and Maneuverability
Bending Section Assy For Olympus BF-1T180 Bronchoscope Parts
Bending Section Assy For Olympus BF-1T180 Bronchoscope Parts ► Brief Description The Olympus BT-1T180 Bending Section assembly included bending section, mesh, angulation wire, coil pipe (helix tube). ► Features Compatibility: Designed for Olympus gastroscopes or similar endoscope models . Function: Replacement. Material: Stainless Steel materials for durability and sterility. Application: Used in gastrointestinal (GI) endoscopy, bronchoscopy, or hysteroscopy procedures. ►
Bending Section Assy For Olympus GIF-Q165 Gastroscope Parts
Bending Section Assy For Olympus GIF-Q165 Gastroscope Parts ► Brief Description The Olympus GIF-Q165 Bending Section assembly included bending section, mesh, angulation wire, coil pipe (helix tube). ► Features Compatibility: Designed for Olympus gastroscopes or similar endoscope models . Function: Replacement. Material: Stainless Steel materials for durability and sterility. Application: Used in gastrointestinal (GI) endoscopy, bronchoscopy, or hysteroscopy procedures. ►
Air Water Valve MH-438 For Olympus MH438 Autoclavable Endoscopy Button Suction Valve Fit CF-140 CF-160 CF-180
Olympus MH-438 Autoclavable Air Water Valve For Endoscopy Button Suction Valve ► Brief Description The Olympus MH-438 Air Water Valve Autoclavable Air Water Suction Valve Fit CF-140 CF-160 CF-180 ► Features Controls the release of air and water mixtures in a controlled manner . Used in Olympus endoscopes Replacement Parts : Olympus may offer OEM replacements (check part number compatibility). ► Common Applications: Colonoscopy, Gastroscopy for Model(s): 140,145,160,165, 170