Refrigeration Parts
XR30CX-5N1C1 Dixell Digital Temperature Controller With 220-240V
Dixell XR30CX-5N1C1 Digital Temperature Controller. GENERAL DESCRIPTION Model XR30CX, format 32 x 74 mm, is a digital thermostat with off cycle defrost designed for refrigeration applications at normal temperature. It provides two relay outputs, one for the compressor, the other one can be used as light, for alarm signalling or as auxiliary output.. It is also provided with 2 NTC or PTC probe inputs, the first one for temperature control, the second one, optional, to connect
Refrigeration Pressure Controller KP15 Model 06126491 8 To 32 Bar PE 4 Bar Fixed KP15 060-126491 R134A/R22/R407C
Refrigeration Pressure Controller KP15 Model 06126491 8 To 32 Bar PE 4 Bar Fixed Specifications: Pressure controls are pressure-activated switches,with a basic function to make or break an electrical circuit which in tur controls a solenoid coil, a contactor or some other functioning part of the system. The set point at which a control closes a contact and makes a circuit is called the cut-in point. The point at which the control opens the switch and breaks the circuit is
TGEZ Series Thermostatic Refrigeration Valves R407c TGEZ 067N4157
TGEZ Series Thermostatic Refrigeration Valves R407c TGEZ 067n4157 Specifications: Regriratant: R22/R404A/R507 Thermostatic expansion valve regulate the flow of refrigerant liquid into The evaporator. The flow is controlled by the valve is thermal bulb which is Attached to the suction line at the outlet of the evaporator. The thermal Bulb senses the evaporator heat and adjusts the valve to admit refrigerant Liquid in accordance with the refrigerating load. ETS series of
TGEZ 067N5007 High efficiency TGEZ Series Refrigeration Compressor Parts Refrigeration Service Valve R407C
TGEZ Series Refrigeration Compressor Parts Refrigeration Service Valve R407c TGEZ 067N5007 Specifications: Regriratant: R22/R404A/R507 Thermostatic expansion valve regulate the flow of refrigerant liquid into The evaporator. The flow is controlled by the valve is thermal bulb which is Attached to the suction line at the outlet of the evaporator. The thermal Bulb senses the evaporator heat and adjusts the valve to admit refrigerant Liquid in accordance with the refrigerating
TX2 068Z3206 Series Refrigeration Valves (068Z3206) R22 CE/ROHS/FCC/SGS -40/+10
Tes20 Series Refrigeration Valves ( 067b3352 ) R404a / R507 Specifications: thermostatic expansion valves(Tex2) Regriratant: R22/R404A/R507 Thermal expansion valve, expansion valve,thermostatic expansion valve,A/C expansion valve Type TEX2 belong the Outer balance Thermostatic expansion valve regulate the flow of refrigerant liquid into the evaporator. The flow is controlled by the valve. The thermal bulb senses the evaporator heat and adjusts the valve to admit refrigerant
TX2 Refrigeration Compressor Parts Refrigeration Valves Therm Expansion Valve 068Z3206 R404A/R22/R507/R407C
TX2 Series Valves / Therm Expansion Valve TX2 068Z3206 Specifications: R22/R407C 3/8in*1/2in Angleway Flare Regriratant:R404A/R22/R507/R407C Thermostatic expansion valve regulate the flow of refrigerant liquid into The evaporator. The flow is controlled by the valve is thermal bulb which is Attached to the suction line at the outlet of the evaporator. The thermal Bulb senses the evaporator heat and adjusts the valve to admit refrigerant Liquid in accordance with the
Angleway Brass Valves Ten55 067b3297 High Efficiency
Angleway Brass Valves Ten55 067b3297, High Efficiency Specifications: Thermostatic expansion valve regulate the flow of refrigerant liquid into the evaporator. The flow is controlled by the valve. The thermal bulb senses the evaporator heat and adjusts the valve to admit refrigerant liquid in accordance with the refrigerating load. More information please check below file: TDEX4 TDEX4,R22 TDEX6-7.5 TDEX6-7.5,R22 TDE(B)X8-19 TDE(B)X8-19,R22 TDEBX20 TDEBX20,R22 TDE(B)X26-40 TDE
Refrigeration Solenoid Valves EVR3 code 032F8116
Refrigeration Solenoid Valves EVR3 code 032F8116 Specifications: Solenoid valves are electrically- controlled open or closed refrigerant flow controlvalves designed for use in liquid, suction and hot gas lines. A normally closed solenoid valve is closed when the coil is de-energised and the plunger is seated. When the solenoid coil is enlarged, the magnetic effect of the coil lifts the plunger and opens the valve. Normally open solenoid valves have reverse action. They are
TN2 SERIES Expansion Valve R134A CODE 068Z3346
TN2 SERIES Expansion Valve R134A CODE 068Z3346 Specifications: thermostatic expansion valves( TN2 SERIES) Refrigerant: R22, R407C, R134A, R404A/R507, R12, R502 Thermostatic expansion valve regulate the flow of refrigerant liquid into the evaporator. The flow is controlled by the valve. The thermal bulb senses the evaporator heat and adjusts the valve to admit refrigerant liquid in accordance with the refrigerating load. More information please check below file: Refrigerant
Electric Thermostat Controller Pressure Controls Kp Series Low pressure controller KP1 060-111266 KP5 060-117866 KP15
Pressure Controls Kp Series KP1 KP5 KP15 Specifications: Pressure controls are pressure-activated switches,with a basic function to make or break an electrical circuit which in tur controls a solenoid coil, a contactor or some other functioning part of the system. The set point at which a control closes a contact and makes a circuit is called the cut-in point. The point at which the control opens the switch and breaks the circuit is called the cut-out point. The difference
KP1 Series Refrigeration Compressor Parts Low pressure control , 8-32 bar range
KP1 Series Refrigeration Compressor Parts Low pressure control , 8-32 bar range Specifications: Pressure controls are pressure-activated switches,with a basic function to make or break an electrical circuit which in tur controls a solenoid coil, a contactor or some other functioning part of the system. The set point at which a control closes a contact and makes a circuit is called the cut-in point. The point at which the control opens the switch and breaks the circuit is
Refrigeration controls Oil Differential Pressure Control MP Series MP54 MP55 series CE 230 V or 115 V a. C. Or d. C.
Refrigeration controls Oil Differential Pressure Control MP Series Specifications: MP Series oil differential pressure control MP-MP-A pressure difference controller, MP 54 and MP 55 oil differential pressure controller is a type of safety switch to prevent the refrigeration compressor oil pressure is too low. If the oil pressure drops below the set value, at a certain time interval, the pressure difference controller operation, the compression. MP 54 and MP 55 oil differenti
Thermostat Controller Dual high Low Pressure controls ammonia Controls
Thermostat Controller Dual high Low Pressure controls ammonia Controls Specifications: Pressure controls are pressure-activated switches,with a basic function to make or break an electrical circuit which in tur controls a solenoid coil, a contactor or some other functioning part of the system. The set point at which a control closes a contact and makes a circuit is called the cut-in point. The point at which the control opens the switch and breaks the circuit is called the
WVFX series Brass Pressure Control Water Valves model WVFX Refrigeration Parts WVFX10 WVFX20
Pressure Controlled Water Valves model WVFX Specifications: Pressure controlled water valves types WVFX are used for regulating the flow of water in refrigeration plant with water-cooled condensers. The water valves give modulating regulation of the condensing pressure and so maintain it constant during operation. When the refrigeration plant is stopped, the cooling water flow is shut off automatically. Please find More Models as below: Type Connection Code no. Water side
Professional Refrigeration Controls Capacity Regulator Model CPCE series CPCE15 034N0083
Refrigeration controls Capacity Regulator Model CPCE LG Specifications: Capacity Regulators A capacity regulator is used for the adaption of the compressor Capacity to the actual evaporator load. They are placed in a by-pass between high and low pressure sides Of the refrigeration plant. In this position they impose a downward Limit on the compressor suction pressure by supplying the low Pressure side with replacement duty in the form of hot gas/cool Gas from the high
Compressor Capacity Regulator Refrigeration controls KVC Series KVC15 034L0147
Refrigeration controls Capacity Regulators KVC Series Specifications: Capacity Regulators A capacity regulator is used for the adaption of the compressor Capacity to the actual evaporator load. They are placed in a by-pass between high and low pressure sides Of the refrigeration plant. In this position they impose a downward Limit on the compressor suction pressure by supplying the low Pressure side with replacement duty in the form of hot gas/cool Gas from the high-pressure
Manual Power refrigeration controls Crankcase Pressure Regulaor model KVLseries KVL12 034L0041
refrigeration controls Crankcase Pressure Regulaor model KVL Specifications: Crankcase pressure regulator type KVL is fitted in the suction line ahead of the compressor. The KVL protects the compressor motor against overload during start-up after long standstill periods or after defrost periods. More Models as below: Model KVL Part Number Model Number Regulating Range kPa (psig) Connections Rated Capacity (kW) R22 R134a R404A R407C Crankcase Pressure Regulator 034L0041 KVL12
Air conditioning plant refrigeration Condensing Pressure Regulator model KVRseries KVR35 034L0100 R22/R134A/R507
refrigeration controls Condensing Pressure Regulator model KVR Specifications: Condensing pressure regulator Refrigerant: R22/R134A/R507 Regular system KVR and NRD is used to maintain a constant and sufficiently high condenser and receiver pressure in refrigeration and air conditioning plant with air-cooled condensers. Please find More Models as below: Model KVR Part Number Model Number Connections Rated Capacity (kw) Rated Hot R22 R134a R404a R407C R22 R134a R404a R407C
Thermostatic expansion Valves Model TDE/TDEX TDEBX - R22 TDES - R404A/R507 TDEZ/TDEBZ - R407C TDEN 068H8331
TDE/TDEX TDEBX - R22 TDES - R404A/R507 TDEZ/TDEBZ - R407C Specifications: Regriratant:R404A/R22/R507/R407C Thermostatic expansion valve regulate the flow of refrigerant liquid into The evaporator. The flow is controlled by the valve is thermal bulb which is Attached to the suction line at the outlet of the evaporator. The thermal Bulb senses the evaporator heat and adjusts the valve to admit refrigerant Liquid in accordance with the refrigerating load. Part Number Model No.
Refrigeration Thermostatic expansion Valves Model TE55 of Brass
Model TE55 - With Interchangeable Orifice Assembly Specifications: Regriratant:R404A/R22/R134a Thermostatic expansion valve regulate the flow of refrigerant liquid into The evaporator. The flow is controlled by the valve is thermal bulb which is Attached to the suction line at the outlet of the evaporator. The thermal Bulb senses the evaporator heat and adjusts the valve to admit refrigerant Liquid in accordance with the refrigerating load. Model TE55 - With Interchangeable