Refrigeration Parts
Refrigeration controls Oil Differential Pressure Control MP Series MP54 MP55 series CE 230 V or 115 V a. C. Or d. C.
Refrigeration controls Oil Differential Pressure Control MP Series Specifications: MP Series oil differential pressure control MP-MP-A pressure difference controller, MP 54 and MP 55 oil differential pressure controller is a type of safety switch to prevent the refrigeration compressor oil pressure is too low. If the oil pressure drops below the set value, at a certain time interval, the pressure difference controller operation, the compression. MP 54 and MP 55 oil differenti
WVFX series Brass Pressure Control Water Valves model WVFX Refrigeration Parts WVFX10 WVFX20
Pressure Controlled Water Valves model WVFX Specifications: Pressure controlled water valves types WVFX are used for regulating the flow of water in refrigeration plant with water-cooled condensers. The water valves give modulating regulation of the condensing pressure and so maintain it constant during operation. When the refrigeration plant is stopped, the cooling water flow is shut off automatically. Please find More Models as below: Type Connection Code no. Water side
Refrigeration Controls PM Pressure temperature regulator PM series
Refrigeration Industry Controls PM Pressure temperature regulators Specifications: PM Series valves are controlled by a pilot valve for regulating the temperature and pressure refrigeration systems to control the main valve. PM main valve can be used in the refrigeration system high / low side suction wet / dry suction pipeline, and no phase transition liquid line (ie, no swelling phenomenon at the valve). PM main valve function depends entirely on the pilot valve is
Professional Refrigeration Controls Capacity Regulator Model CPCE series CPCE15 034N0083
Refrigeration controls Capacity Regulator Model CPCE LG Specifications: Capacity Regulators A capacity regulator is used for the adaption of the compressor Capacity to the actual evaporator load. They are placed in a by-pass between high and low pressure sides Of the refrigeration plant. In this position they impose a downward Limit on the compressor suction pressure by supplying the low Pressure side with replacement duty in the form of hot gas/cool Gas from the high
Compressor Capacity Regulator Refrigeration controls KVC Series KVC15 034L0147
Refrigeration controls Capacity Regulators KVC Series Specifications: Capacity Regulators A capacity regulator is used for the adaption of the compressor Capacity to the actual evaporator load. They are placed in a by-pass between high and low pressure sides Of the refrigeration plant. In this position they impose a downward Limit on the compressor suction pressure by supplying the low Pressure side with replacement duty in the form of hot gas/cool Gas from the high-pressure
Manual Power refrigeration controls Crankcase Pressure Regulaor model KVLseries KVL12 034L0041
refrigeration controls Crankcase Pressure Regulaor model KVL Specifications: Crankcase pressure regulator type KVL is fitted in the suction line ahead of the compressor. The KVL protects the compressor motor against overload during start-up after long standstill periods or after defrost periods. More Models as below: Model KVL Part Number Model Number Regulating Range kPa (psig) Connections Rated Capacity (kW) R22 R134a R404A R407C Crankcase Pressure Regulator 034L0041 KVL12
Air conditioning plant refrigeration Condensing Pressure Regulator model KVRseries KVR35 034L0100 R22/R134A/R507
refrigeration controls Condensing Pressure Regulator model KVR Specifications: Condensing pressure regulator Refrigerant: R22/R134A/R507 Regular system KVR and NRD is used to maintain a constant and sufficiently high condenser and receiver pressure in refrigeration and air conditioning plant with air-cooled condensers. Please find More Models as below: Model KVR Part Number Model Number Connections Rated Capacity (kw) Rated Hot R22 R134a R404a R407C R22 R134a R404a R407C
Electronic Temperature Controller type EKC EKD EKA EKS Series
Refrigeration controls Electronic Controller Controller type EKC EKD EKA EKS Product Description EKC 201 (for panel mounting) and EKC 301 (for DIN-rail mounting) have been specially developed for control duties in refrigeration plant so that operation, setting and programming are optimised and simplified as much as possible. All controllers are designed for room temperature control via pump down or compressor start/stop and have been grouped into four main applications
Thermostatic expansion Valves Model TDE/TDEX TDEBX - R22 TDES - R404A/R507 TDEZ/TDEBZ - R407C TDEN 068H8331
TDE/TDEX TDEBX - R22 TDES - R404A/R507 TDEZ/TDEBZ - R407C Specifications: Regriratant:R404A/R22/R507/R407C Thermostatic expansion valve regulate the flow of refrigerant liquid into The evaporator. The flow is controlled by the valve is thermal bulb which is Attached to the suction line at the outlet of the evaporator. The thermal Bulb senses the evaporator heat and adjusts the valve to admit refrigerant Liquid in accordance with the refrigerating load. Part Number Model No.
Refrigeration Parts Interchangeable Orifice Assembly Brass Valves Model TES20 067B3352
Model TE20 - With Interchangeable Orifice Assembly Specifications: Regriratant:R404A/R22/R134a Thermostatic expansion valve regulate the flow of refrigerant liquid into The evaporator. The flow is controlled by the valve is thermal bulb which is Attached to the suction line at the outlet of the evaporator. The thermal Bulb senses the evaporator heat and adjusts the valve to admit refrigerant Liquid in accordance with the refrigerating load. Model TE20 - With Interchangeable
Thermostatic expansion valve Refrigeration Parts Model T12 067B3210 R404A/R22/R134a
valves Model T12 - With Interchangeable Orifice Assembly Specifications: Regriratant:R404A/R22/R134a Thermostatic expansion valve regulate the flow of refrigerant liquid into The evaporator. The flow is controlled by the valve is thermal bulb which is Attached to the suction line at the outlet of the evaporator. The thermal Bulb senses the evaporator heat and adjusts the valve to admit refrigerant Liquid in accordance with the refrigerating load. Model T12 - With Interchangea
Thermostatic Expansion Valves Orifice Refrigeration Tools And Equipment NO.00-06 NO.02 068-2015
Thermostatic Expansion Valves Orifice-NO.00-06 Product Description Origional orifice for thermostatic expansion valve 1. TX2 / tex-2 X - represents the R22 refrigerant system; 2. TZ2 / TEZ2 Z - represents the R407C refrigerant system; 3. TN2 / TEN2 N - stands for R134A refrigerant system; 4. TS2 / TES2 S - represents the R404A/R507 refrigerant system; 5. TF2 / TEF2 F - stands for R12 refrigerant system; 6. TY2 / TEY2, Y - for the R502 refrigerant system; The T2 / TE2
valves Model T2 & TE2 with Interchangeable Orifice Assembly
valves Model T2 & TE2 with Interchangeable Orifice Assembly Specifications: Regriratant:R404A/R507/R22/R134a/R12/R502 Thermostatic expansion valve regulate the flow of refrigerant liquid into The evaporator. The flow is controlled by the valve is thermal bulb which is Attached to the suction line at the outlet of the evaporator. The thermal Bulb senses the evaporator heat and adjusts the valve to admit refrigerant Liquid in accordance with the refrigerating load. TX Valves
CBV28S 032B4011 Shut-off Ball Valve Refrigeration Compressor Parts for Industrial / Household Usage
Brass Ball Valve Refrigeration Compressor Parts for Industrial / Household Usage GBC ball valves are manually operated shut-off valves suitable for bi-directional flow. GBC valves are used in liquid, suction and hot gas lines in refrigeration, freezing and air conditioning systems. GBC valves offer maximum tightness, both externally as well as internally across the seat. GBC valves give maximum flow in the fully open position. They are designed for operation in all temperatur
Orifice assembly Refrigeration Compressor Parts Thermostatic Expansion Valves Orifice NO.0-6
Orifice assembly Refrigeration Compressor Parts Thermostatic Expansion Valves Product Description Thermostatic Expansion Valves Orifice Origional orifice for thermostatic expansion valve Orifice no. (TR) Ratedcapacityintons(TR) kW Ratedcapacity inkW Code No. R22 R407C R134a R404A R507 R12 R502 R22 R407C R134a R404A R12 R507 R502 0X 0.15 0.16 0.11 0.11 0.5 0.5 0.4 0.38 068-2002 00 0.3 0.3 0.25 0.21 0.2 0.2 1.0 1.1 0.9 0.7 0.7 0.7 068-2003 01 0.7 0.8 0.5 0.45 0.3 0.3 2.5 2.7 1
Vibration Resistant Refrigeration Compressor Parts Corrugated Metel Hose VAF Series
Vibration Resistant Refrigeration Compressor Parts Corrugated Metel Hose Description Vibration Resistant Corrugated Metel Hose is a welded assemdly of corrugated metal hose, metal connector, braided metallic wire sleeve, metal clamping ring and red copper tube. · VAF Vibration Resistant Corrugated Metel Hose is a vibration resistant connection piece to be used to prevent the piping from break caused by vibration. · VAF Vibration Resistant Corrugated Metel Hose is used on the
Semi Hermetic Compressor Refrigeration Tools And Equipment Gasket Set
Semi - Hermetic Compressor Refrigeration Tools And Equipment Specifications: Semi-Hermetic Compressor Based on one technical concept, our semi-hermetic reciprocating compressors cover the entire spectrum of applications of conventional, chlorine-free HFC as well as natural refrigerants. They distinguish themselves by a robust valve plate design, a high quality and wear resistant drive gear, are easy-to-service and offer good speed control at minimum energy requirements as
Refrigeration Pressure Control KP Series Pressure Activated Switches
Refrigeration Compressor Parts Pressure Control KP Series , pressure-activated switches Specifications: Pressure controls are pressure-activated switches,with a basic function to make or break an electrical circuit which in tur controls a solenoid coil, a contactor or some other functioning part of the system. The set point at which a control closes a contact and makes a circuit is called the cut-in point. The point at which the control opens the switch and breaks the circuit
110V 230V Dixell Thermostat Controller Digital Temperature Controller XR Series
Dixell Thermostat controller Temperature Controller XR Series Product description: 1.Model: XR03CX -5N0C1 2.Control mode:intelligent temperature control regulator 3.Measuring objects: cold cabinet, display cabinet, water chiller 4.Temperature range: - 50 to + 150 ℃ 5.Temperature measurement error: 0.1 ℃ 6.Installation type: embedded 7.Opening size: 71*29mm 8.Power supply: 110, 230Vac 9.Probe inputs 10.Thermostat: NTC 11.Digital inputs 12.Alarm, start defrost, AUX, door switch
Air Conditioner Carel Refrigeration Controls Digital Thermostat IR33 Series
Air Conditioner Carel Refrigeration Controls Digital Thermostat Carel control IR33 Series Specifications: MODELS ir33: 12 Vac IR33S00N00 IR33S00N0A IR33Y00N00 IR33C00N00 IR33C00N0A IR33C00R00 ir33: 12 to 24 Vac IR33S0LN00 IR33S0LR00 IR33S0LC00 IR33Y0LR00 IR33C0LN00 IR33C0LR00 IR33C0LB00 IR33C7LN00 IR33C7LR00 IR33C7LN01 ir33: 115 Vac