Plastic Testing Equipment
Mid-size Fire Test Furnace for Building Element Fire Endurance Testing
Mid-size Fire Test Furnace for Building Element Fire Endurance Testing Other requirements -The furnace top shell is insulated with low insulation materials -The combustion system is capable of generating standard heat within the furnace chamber, Time temperature curve with a duration of up to 240 minutes -The furnace wall lining/insulation layer should be made of ceramic fiber modules or equivalent materials that meet the testing standards in terms of temperature and density
GB/T 11785-2005 Standard Floor Covering Thermal Radiation Tester TTech-GBT11785
Floor Material Thermal Radiation Test Apparatus, Model TTech-GBT11785, Compliant with GB/T 11785-2005 Product Introduction The critical radiation flux is the main parameter for assessing the fire hazard of flooring materials, which characterizes the ability of flooring material samples to burn and spread under external thermal radiation conditions. It is an important indicator in the classification system for the combustion of flooring building products; According to the
Floor Material Thermal Radiation Test Apparatus, Model TTech-GBT11785, Compliant with GB/T 11785-2005
Floor Material Thermal Radiation Test Apparatus, Model TTech-GBT11785, Compliant with GB/T 11785-2005 Product Introduction The critical radiation flux is the main parameter for assessing the fire hazard of flooring materials, which characterizes the ability of flooring material samples to burn and spread under external thermal radiation conditions. It is an important indicator in the classification system for the combustion of flooring building products; According to the
Static (sand pressure) mechanical load testing equipment
Static (sand pressure) mechanical load testing equipment 1. Meet the standard: IEC61215-2 MQT16 IEC61730-2 MST34 2. Test objective: To determine the ability of the component to withstand static loads such as wind, snow, or icing. 3. Main equipment parameters The maximum size of the test sample is 2600 * 1400mm (customizable) The maximum load of the testing equipment is ≤ 12500Pa Pressure control accuracy ± 5% (adjusted according to the number of sandbags) Circuit continuity
PID parameter calibration system
PID parameter calibration system Meet the standards: IEC61215-2 MQT21 IEC62804 Product Introduction The PID power supply has multiple channel outputs, which can provide multiple components for simultaneous testing. The voltage can be continuously adjusted, and the voltage parameters can be displayed in real time. 1. The power supplies are independent of each other and can output different polarities and voltage values at the same time. 2. PID monitoring communication, and
Thermal Cycling Humidity Test Cabinet
Thermal Cycling Humidity Test Cabinet meet the standard IEC61215-2 MQT13 IEC61215-2 MQT21 IEC61730-2 MST53 IEC62804 Test objective: To determine the ability of components to withstand long-term moisture infiltration effects Main technical parameters: Temperature range RT~150 ℃ Temperature deviation ≤± 1.0 ℃ (full load) Temperature fluctuation ≤ ± 0.5 ℃ (full load) Uniformity of box temperature ≤ 2 ℃ (full load) Sample temperature uniformity ≤ 2 ℃ (after stabilizing for half
Temperature Humidity Alternating Test Chamber
Temperature Humidity Alternating Test Chamber meet the standard IEC61215-2 MQT13 IEC61215-2 MQT21 IEC61730-2 MST53 IEC62804 Test objective: To determine the ability of components to withstand long-term moisture infiltration effects Main technical parameters: Temperature range RT~150 ℃ Temperature deviation ≤± 1.0 ℃ (full load) Temperature fluctuation ≤ ± 0.5 ℃ (full load) Uniformity of box temperature ≤ 2 ℃ (full load) Sample temperature uniformity ≤ 2 ℃ (after stabilizing
Thermal Humidity Aging Test Chamber
Thermal Humidity Aging Test Chamber meet the standard IEC61215-2 MQT13 IEC61215-2 MQT21 IEC61730-2 MST53 IEC62804 Test objective: To determine the ability of components to withstand long-term moisture infiltration effects Main technical parameters: Temperature range RT~150 ℃ Temperature deviation ≤± 1.0 ℃ (full load) Temperature fluctuation ≤ ± 0.5 ℃ (full load) Uniformity of box temperature ≤ 2 ℃ (full load) Sample temperature uniformity ≤ 2 ℃ (after stabilizing for half an
Medium-Scale Fire Furnace for Building Element Fire Test
Medium-Scale Fire Furnace for Building Element Fire Test Other requirements -The furnace top shell is insulated with low insulation materials -The combustion system is capable of generating standard heat within the furnace chamber, Time temperature curve with a duration of up to 240 minutes -The furnace wall lining/insulation layer should be made of ceramic fiber modules or equivalent materials that meet the testing standards in terms of temperature and density -The burner
Scratch resistant testing machine
Scratch resistant testing machine Meets standard: IEC61730-2 MQT12 Test objective: To determine whether polymer materials as components on the front and rear surfaces can withstand routine operations during installation and maintenance without the risk of personal electric hazard 1. Unique selling point: 12 years of professional research and development, only solving problems for customers. 2. Professional team: A technical research and development team with 12 years of
Hail experiment apparatus
Hail experiment apparatus Meets standard: IEC61215-2 MQT17 Test objective: To evaluate the component's ability to withstand hail impact. Main technical parameters: Ice hockey size 25mm; 35mm;45mm; 55mm;65mm; 75mm; (optional) Ice hockey diameter accuracy ≤± 5% Ice hockey quality accuracy ≤± 2% Ice hockey speed control accuracy ≤± 5% Accuracy of speed sensor ≤± 2% Electronic balance 100g/0.1mg; 250g/0.1mg 2 refrigerators Product Features: 1. The launch speed of ice hockey can
Wet leakage testing system
Wet leakage testing system Meets standard: IEC61215-2 MQT15 Test purpose: To evaluate the insulation performance of components under humid working conditions, and verify whether moisture from rain, fog, dew, or snow can enter the working parts of the internal circuits of the components. If moisture enters there, it may cause corrosion, leakage, or safety accidents. Product Features: -The standard output of the device is DC2000V, which can be upgraded to a maximum of 2500V
Constant Temperature and Humidity Test Cabinet
Constant Temperature and Humidity Test Cabinet High temperature and high humidity test chamber meet the standard IEC61215-2 MQT13 IEC61215-2 MQT21 IEC61730-2 MST53 IEC62804 Test objective: To determine the ability of components to withstand long-term moisture infiltration effects Main technical parameters: Temperature range RT~150 ℃ Temperature deviation ≤± 1.0 ℃ (full load) Temperature fluctuation ≤ ± 0.5 ℃ (full load) Uniformity of box temperature ≤ 2 ℃ (full load) Sample
Mid-Size Fire Endurance Furnace for Building Material Testing
Mid-Size Fire Endurance Furnace for Building Material Testing Other requirements -The furnace top shell is insulated with low insulation materials -The combustion system is capable of generating standard heat within the furnace chamber, Time temperature curve with a duration of up to 240 minutes -The furnace wall lining/insulation layer should be made of ceramic fiber modules or equivalent materials that meet the testing standards in terms of temperature and density -The
Medium Fire Endurance Test Chamber
Medium Fire Endurance Test Chamber Other requirements -The furnace top shell is insulated with low insulation materials -The combustion system is capable of generating standard heat within the furnace chamber, Time temperature curve with a duration of up to 240 minutes -The furnace wall lining/insulation layer should be made of ceramic fiber modules or equivalent materials that meet the testing standards in terms of temperature and density -The burner slag should be made of
Thermal radiation tester for flooring materials GB/T 11785-2005, TTech-GBT11785
Thermal radiation tester for flooring materials GB/T 11785-2005, TTech-GBT11785 Standard -ISO 9239-1: Fire reaction testing of flooring materials - Part 1: Testing the combustion performance of flooring materials using a radiant heat source -ISO 9239-2: Fire Reaction Testing of Flooring Materials - Part 2: Testing Flame Spread at a Heat Flux of 25 kW/㎡ -ASTM E 648: Standard Test for Critical Radiant Flux of Floor Covering Systems Using Radiant Heat Energy -ASTM E 970:
Wire and cable bundle combustion and heat release testing device EN50399
Product Introduction The wire and cable bundle vertical combustion tester is designed according to the requirements of UL1685, GB18380.31 standards for wire and cable bundle combustion tests and other relevant regulations. And comply with IEC60332-3-10, KSCIEC60332-3-21~25 (Class A~D) standards. When a certain amount of gas is supplied to the box and a standard ignition source is used for ignition, this instrument can be used to test the vertical flame spread to the
Impulse voltage generator
Impulse voltage generator Meets standard: IEC61730-2 MST14 Test purpose: This test is used to verify the ability of solid insulation materials in components to withstand overvoltage caused by atmospheric environment. It also involves overvoltage states caused by low-voltage equipment switches. Equipment Introduction: It is specifically designed for testing the pulse voltage of solar cell modules (solar panels). The generator can generate a surge voltage waveform of 1.2/50 μ s
Product Temperature Humidity Tolerance Tester
Product Temperature Humidity Tolerance Tester meet the standard IEC61215-2 MQT13 IEC61215-2 MQT21 IEC61730-2 MST53 IEC62804 Test objective: To determine the ability of components to withstand long-term moisture infiltration effects Main technical parameters: Temperature range RT~150 ℃ Temperature deviation ≤± 1.0 ℃ (full load) Temperature fluctuation ≤ ± 0.5 ℃ (full load) Uniformity of box temperature ≤ 2 ℃ (full load) Sample temperature uniformity ≤ 2 ℃ (after stabilizing
Intelligent Climate Environmental Test Chamber
Intelligent Climate Environmental Test Chamber meet the standard IEC61215-2 MQT13 IEC61215-2 MQT21 IEC61730-2 MST53 IEC62804 Test objective: To determine the ability of components to withstand long-term moisture infiltration effects Main technical parameters: Temperature range RT~150 ℃ Temperature deviation ≤± 1.0 ℃ (full load) Temperature fluctuation ≤ ± 0.5 ℃ (full load) Uniformity of box temperature ≤ 2 ℃ (full load) Sample temperature uniformity ≤ 2 ℃ (after stabilizing