4 Cores Cable
ZR-YJV 3x300mm²+1x150mm² XLPE Copper Cable 0.6/1kV Flame Retardant
ZR-YJV 3x300mm²+1x150mm² XLPE Copper Cable 0.6/1kV Flame Retardant ZR-YJV 3×300+1×150 mm² — Cable Specification & Engineering Data 1. Product Definition & Rating Framework. Sitting at the top of the conventional flame-retardant 3+1-core catalogue, ZR-YJV 3×300+1×150 combines three 300 mm² copper phase conductors with a dedicated 150 mm² copper return conductor, each insulated in XLPE and jointly protected by a single ST2 PVC oversheath. The cable is engineered for 0.6/1 kV
Copper 4 Cores Cable 3x10mm² + 1x6mm2 For Three Phase Power Wiring
3+1 Core ZR-YJV Flame Retardant Copper Cable 3x10mm²+1x6mm² for Three Phase Power Wiring Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame-retardant grade, contains halogen (Cl) 0.6/1 kV Rated voltage U₀/U = 600/1000 V; Uₘ = 1.2 kV 3×10+1×6 mm² Three phase cores of 10 mm² copper + one smaller neutral core
3+1 Core Flame Retardant 4 Cores Cable For Factory Three Phase Main Power
ZR-YJV 3+1 Core Flame Retardant Copper Cable 3x16mm²+1x10mm² for Factory Three-Phase Main Power Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame-retardant grade, contains halogen (Cl) 0.6/1 kV Rated voltage U₀/U = 600/1000 V; Uₘ = 1.2 kV 3×16+1×10 mm² Three phase cores of 16 mm² copper + one reduced
3x25mm2+1x16mm2 25 Sq Mm 4 Core Cable For Three Phase Retrofit Projects
Flame Retardant 3+1 Core Copper Cable ZR-YJV 3x25mm²+1x16mm² for Three Phase Retrofit Projects Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame-retardant grade, contains halogen (Cl) 0.6/1 kV Rated voltage U₀/U = 600/1000 V; Uₘ = 1.2 kV 3×25+1×16 mm² Three phase cores of 25 mm² copper + one reduced
Low Voltage 4 Cores Cable ZR-YJV 3×35mm2+1×16mm2 XLPE Cable
Low Voltage Flame Retardant ZR-YJV 3×35mm²+1×16mm² XLPE Cable for Mobile Power Distribution Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame-retardant grade, contains halogen (Cl) 0.6/1 kV Rated voltage U₀/U = 600/1000 V; Uₘ = 1.2 kV 3×35+1×16 mm² Three phase cores of 35 mm² copper + one reduced neutral
OEM Copper Xlpe Cable 4 Core Heat Resistant Flex 3×50mm2+1×25mm2 For Heavy Duty
Flame Retardant Copper Conductor ZR-YJV 3×50mm²+1×25mm² for Heavy-Duty Three Phase Supply Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame-retardant grade, contains halogen (Cl) 0.6/1 kV Rated voltage U₀/U = 600/1000 V; Uₘ = 1.2 kV 3×50+1×25 mm² Three phase cores of 50 mm² copper + one reduced neutral
Copper Conductor Flame Retardant XLPE Cable ZR-YJV 3×95mm²+1×50mm² for Site Power Wiring
Copper Conductor Flame Retardant XLPE Cable ZR-YJV 3×95mm²+1×50mm² for Site Power Wiring ZR-YJV 3×95+1×50 mm² — Cable Specification & Engineering Data 1. Overview & Ratings. ZR-YJV 3×95+1×50 is a heavy-duty flame-retarding 3+1-core cable: three 95 mm² copper phase conductors and one 50 mm² copper neutral conductor, XLPE insulation and one ST2 PVC jacket, rated 0.6/1 kV (Um = 1.2 kV), 50 Hz; manufactured and proof-tested to GB/T 12706.1 / IEC 60502-1, stranding to GB/T 3956,
3×120mm2+1×70mm2 4 Cores Cable Power Distribution Flame Retardant XLPE Insulated Copper
Power Distribution Cable ZR-YJV 3×120mm²+1×70mm², Flame Retardant XLPE Insulated Copper Wire Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame-retardant grade, contains halogen (Cl) 0.6/1 kV Rated voltage U₀/U = 600/1000 V; Uₘ = 1.2 kV 3×120+1×70 mm² Three phase cores of 120 mm² copper + one reduced
Copper Power Cable 4 Core ZR-YJV 3×150mm2+1×70mm2 For Power System
Flame Retardant Copper Cable ZR-YJV 3×150mm²+1×70mm² for Commercial Building Power System Technical Datasheet — ZR-YJV 0.6/1 kV 3×150+1×70 mm² Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame-retardant grade, contains halogen (Cl) 0.6/1 kV Rated voltage U₀/U = 600/1000 V; Uₘ = 1.2 kV 3×150+1×70 mm² Three
Flame Retardant XLPE Insulated ZR-YJV 3×185mm²+1×95mm² Copper Cable for Power Grid Distribution Projects
Flame Retardant XLPE Insulated ZR-YJV 3×185mm²+1×95mm² Copper Cable for Power Grid Distribution Projects Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame-retardant grade, contains halogen (Cl) 0.6/1 kV Rated voltage U₀/U = 600/1000 V; Uₘ = 1.2 kV 3×185+1×95 mm² Three phase cores of 185 mm² copper + one
ZR-YJV 3x240mm²+1x120mm² XLPE Copper Cable 0.6/1kV Flame Retardant
ZR-YJV 3x240mm²+1x120mm² XLPE Copper Cable 0.6/1kV Flame Retardant ZR-YJV 3×240+1×120 mm² — Cable Specification & Engineering Data 1. Product Identity & Ratings. A heavy-duty flame-retardant 3+1-core low-voltage cable, ZR-YJV 3×240+1×120 pairs three 240 mm² copper phase conductors with a single 120 mm² copper neutral, all insulated in XLPE and protected by one ST2 PVC jacket. It is rated 0.6/1 kV (Um = 1.2 kV) at 50 Hz, produced and proof-tested in line with GB/T 12706.1 /
ZC-YJV 4x50mm² Class C Flame Retardant XLPE Copper Power Cable for Building Distribution
ZC-YJV 4x50mm² Class C Flame Retardant XLPE Copper Power Cable for Building Distribution Cable Designation & Meaning Code Meaning ZC Flame retardant Category C (GB/T 18380.3) YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath 4×50 mm² Four cores, each 50 mm² copper (3 phases + 1 neutral, no separate earth) Construction: XLPE insulated, copper conductor, PVC sheathed, flame-retardant Category C, four-core low-voltage power cable. ZC-YJV 4×50 mm² (C-class flame
XLPE Insulated 4 Core Shielded Cable Copper Power ZR-YJV 4x300mm2 For Power Transmission
XLPE Insulated Flame Retardant Copper Cable ZR-YJV 4*300mm² for Power Transmission Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame-retardant grade, contains halogen (Cl) 0.6/1 kV Rated voltage U₀/U = 600/1000 V; Uₘ = 1.2 kV 4×300 mm² Four cores, nominal copper conductor area 300 mm² per core ZR-YJV 4×300
Copper Conductor 4 Cores Cable ZR-YJV 4x240mm2 Flame Retardant Cable For Industrial
Copper Conductor ZR-YJV 4*240mm² Flame Retardant Cable for Industrial Wiring Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame-retardant grade, contains halogen (Cl) 0.6/1 kV Rated voltage U₀/U = 600/1000 V; Uₘ = 1.2 kV 4×240 mm² Four cores, nominal copper conductor area 240 mm² per core ZR-YJV 4×240 mm² — Cable Engineering
ZR-YJV 4 Core Electrical Cable 4x185mm2 Flame Retardant Copper Power Distribution
ZR-YJV 4*185mm² Flame Retardant 4 Core Copper Power Distribution Cable Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame-retardant grade, contains halogen (Cl) 0.6/1 kV Rated voltage U₀/U = 600/1000 V; Uₘ = 1.2 kV 4×185 mm² Four cores, nominal copper conductor area 185 mm² per core ZR-YJV 4×185 mm² — Cable Engineering Data 1. Product
ZR-YJV 4*150mm² Flame Retardant Copper Power Cable for Industrial Power Distribution
ZR-YJV 4*150mm² Flame Retardant Copper Power Cable for Industrial Power Distribution Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame-retardant grade, contains halogen (Cl) 0.6/1 kV Rated voltage U₀/U = 600/1000 V; Uₘ = 1.2 kV 4×150 mm² Four cores, nominal copper conductor area 150 mm² per core ZR-YJV 4×150 mm² — Specification Data
ZR-YJV 4*120mm² Flame Retardant Copper Power Cable for Building & Industrial Wiring
ZR-YJV 4*120mm² Flame Retardant Copper Power Cable for Building & Industrial Wiring Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame-retardant grade, contains halogen (Cl) 0.6/1 kV Rated voltage U₀/U = 600/1000 V; Uₘ = 1.2 kV 4×120 mm² Four cores, nominal copper conductor area 120 mm² per core ZR-YJV 4×120 mm² — Technical Product
ZR-YJV 4x95mm² Flame Retardant Copper Core Power Cable for Industrial Construction
ZR-YJV 4x95mm² Flame Retardant Copper Core Power Cable for Industrial Construction Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame-retardant grade, contains halogen (Cl) 0.6/1 kV Rated voltage U₀/U = 600/1000 V; Uₘ = 1.2 kV 4×95 mm² Four cores, nominal copper conductor area 95 mm² per core ZR-YJV 4×95 mm² — Cable Technical Data 1.
ZR-YJV 4×70mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution
ZR-YJV 4×70mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame-retardant grade, contains halogen (Cl) 0.6/1 kV Rated voltage U₀/U = 600/1000 V; Uₘ = 1.2 kV 4×70 mm² Four cores, nominal copper conductor area 70 mm² per core ZR-YJV 4×70 mm² —
ZR-YJV 4×50mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution
ZR-YJV 4×50mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution Technical Datasheet — ZR-YJV 0.6/1 kV 4×50 mm² Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — flame-retardant grade, contains halogen (Cl) 0.6/1 kV Rated voltage U₀/U = 600/1000 V; Uₘ = 1.2 kV 4×50 mm² Four