Portable Compact Gasoline Generator Forced Air Cooling 110/220V

 

common fault:

 

The no-load voltage is too high:


(1) Automatic voltage regulator is out of control. The excitation winding current of no-load exciter is too large. Check the automatic voltage regulator.


(2) The setting voltage is too high to reset the voltage.


Excitation current of exciter:


(1) The rectifier element has one or two components in the positive and negative circuit, check with a multimeter, replace the damaged components.


(2) The main generator or exciter part of the excitation winding short circuit, measure the DC resistance value of each pole coil. Replace the coil with a short circuit fault.


Steady-state voltage adjustment rate:


Automatic voltage regulator has a fault check and troubleshoot.


High vibration:


(1) Poor docking with prime mover check and correct docking. After the bolts are fastened, ensure that the generator and the prime mover axis are straight and concentric.


(2) The rotor dynamic balance is not good, occurs after the rotor is rewound, should find the positive dynamic balance.


(3) Short-circuit of the excitation winding of the main generator measure the DC resistance of each pole and find out the short-circuit fault point. Replace the coil.


(4) Bearing damage, generally bearing cover overheating phenomenon, replace the bearing.


(5) If the prime mover is faulty, check the prime mover.


overheating:


(1) The generator is overloaded, so that the load current and voltage do not exceed the rated value.


(2) The load power factor is too low, adjust the load, so that the excitation current does not exceed the rated value.


(3) If the speed is too low, adjust the speed to the rated value.


(4) There is a short circuit in some windings of the generator. Find out the short circuit and correct or replace the coil.


(5) The air duct is blocked, the obstacles are removed, the motor is dismantled, and the air duct is thoroughly blown.

 

Product Description:

 

DIGITAL INVERTER GENERATOR 3.3HP/2KW
Model Number 8896219
Number of phases 1 ph
Maximum power 2kw
Rated power 1.85kw
Voltage/frequency 230v/50hz
Power factor 1
Engine
Max.engine power 2.5kw(3.3hp/5500/min)
Displacement 80cc
Starting recoil
Consumption approx. 0.9 1/kwh
Tank volume 4.5 l
Generator
Type of generator multipole,digital control,inverter.
AC rated current 8.0A/230V
DC rated current 8.3A/12V
Weight 21.6kg
Dimension 42x52x29cm

 

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Guangdong ALI Testing Equipment Co,.Ltd
Location No. 2, Shajiao Sijia Gate, Humen Town, Dongguan City, Guangdong Province, China
Contact Person Kris

Request A Quote

Please check your email address.
Your message must be at least 20 characters.