Electronic Cummins Diesel Generators With Water Cooling, 800KW, 3 phase,50HZ,open type
1, Model:CCEC Cummins KTA38-G5, 4-cycle
2, Standby Power:880KW / 1100KVA
3, Prime Power(50Hz): 800KW / 1000KVA
3, Air Intake System:Turbo, Water/Air cooling
4, Fuel System:PT type fuel pump, EFC
5, Cylinder Arrangement:12 in “v”
6, Rated RPM:1500rpm
7, Governor Type:Electronic
8, Protection Grade:IP23
9, Connecting Type:3 Phase and 4 Wires, “Y” type connecting
Electronic Cummins Diesel Generators With Water Cooling
|
Standby Power(50Hz) |
880KW / 1100KVA |
|
Prime Power(50Hz) |
800KW / 1000KVA |
Dimension & Weight
|
Standard Configuration (Open Type) |
|
Overall Size: 4350(mm)×2060(mm)×2130(mm) |
|
Weight: 7430kg |
|
General Features: |
|
Engine (CCEC Cummins KTA38-G5) |
|
Radiator 40OC max, fans are driven by belt, with safety guard |
|
24V charge alternator |
|
Alternator: single bearing alternator IP23, insulation class H/H |
|
Absorber |
|
Dry type air filter, double fuel filter, oil filter, coolant filter |
|
Main line circuit breaker |
|
Standard control panel |
|
Two12V batteries, rack and cable |
|
Ripple flex exhaust pipe, exhaust siphon, flange, muffler |
|
User manual |
Engine Data
|
Manufacturer / Model: |
CCEC Cummins KTA38-G5, 4-cycle |
|
Air Intake System: |
Turbo, Water/Air cooling |
|
Fuel System: |
PT type fuel pump, EFC |
|
Cylinder Arrangement: |
12 in “v” |
|
Displacement: |
37.8L |
|
Bore and Stroke: |
159*159(mm) |
|
Compression Ratio: |
13.9:1 |
|
Rated RPM: |
1500rpm |
|
Max. Standby Power at Rated RPM: |
970KW/1319HP |
|
Governor Type: |
Electronic |
|
Exhaust System |
|
|
Exhaust Gas Flow: |
3306L/s |
|
Exhaust Temperature: |
513 ℃ |
|
Max Back Pressure: |
10kPa |
|
Air Intake System |
|
|
Max Intake Restriction: |
6.23kPa |
|
Consumption: |
1213L/s |
|
Air Flow: |
30425L/s |
|
Fuel System |
|
|
100%( Prime Power) Load: |
202 g/Kw.h |
|
75%(Prime Power) Load: |
207g/Kw.h |
|
50%(Prime Power) Load:: |
218g/Kw.h |
|
100%( Prime Power) Load: |
200L/h |
|
Oil System |
|
|
Total Oil Capacity |
135L |
|
Oil Consumption: |
≤4g/kwh |
|
Engine Oil Tank Capacity: |
114L |
|
Oil Pressure at Rated RPM: |
310-448kPa |
|
Cooling System |
|
|
Total Coolant Capacity: |
258L |
|
Thermostat: |
82-93℃ |
|
Max Water Temperature: |
104℃ |
Alternator SpecifiCAT-parts-partsion
GENERAL DATA
Compliance with GB755, BS5000, VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1359 standards.
Alternator Data
|
Number of Phase: |
3 |
|
Connecting Type: |
3 Phase and 4 Wires, “Y” type connecting |
|
Number of Bearing: |
1 |
|
Power Factor: |
0.8 |
|
Protection Grade: |
IP23 |
|
Altitude: |
≤1000m |
|
Exciter Type: |
Brushless, self-exciting |
|
Insulation Class, Temperature Rise: |
H/H |
|
Telephone Influence Factor (TIF): |
<50 |
|
THF: |
<2% |
|
Voltage Regulation, Steady State: |
≤±1% |
|
Alternator Capacity: |
1030KVA |
|
Alternator Efficiencies: |
95.1% |
|
Air Cooling Flow: |
1.61m3/s |
Generating set data:
|
Voltage Regulation: |
≥±5% |
|
Voltage Regulation, Stead State: |
≤±1% |
|
Sudden Voltage Warp (100% Sudden Reduce): |
≤+25% |
|
Sudden Voltage Warp (Sudden Increase): |
≤-20% |
|
Voltage Stable Time (100% Sudden Reduce): |
≤6S |
|
Voltage Stable Time (Sudden Increase) |
≤6S |
|
Frequency Regulation, Stead State: |
≤5% |
|
Frequency Waving: |
≤0.5% |
|
Sudden Frequency Warp (100% Sudden Reduce): |
≤+12% |
|
Sudden Frequency Warp (Sudden Increase): |
≤-10% |
|
Frequency Recovery Time (100% Sudden Reduce): |
≤5S |
|
Frequency Recovery Time (Sudden Increase): |
≤5S |
Competitive Advantage:
High Performance of loading Easy start
Nice protection User-friendly operation
Low running cost Environmental Long service life