IEC 61058 Power Load Cabinet Professional Plug And Socket Tester , Fully Verify The Socket Load Safety And Performance
IEC 61058 power load cabinet professional plug and socket tester, fully verify the socket load safety and performance
Core features of the product:
HC9915A power load cabinet is a high-end device designed for plug & socket load performance testing, integrating high current load simulation, temperature rise detection, and stability analysis. Whether it is a household socket, industrial plug, or new energy charging pile interface, HC9915A can accurately simulate the real load scenario, verify the overload capacity and durability of the socket, ensure 100% compliance with international safety standards, and help enterprises quickly pass certification and seize the global market!
International reference standards:
IEC 60884 General requirements for plugs and sockets for household and similar purposes
IEC 60309 Industrial plugs, sockets and couplers
UL 498 American standard socket safety certification
GB/T 2099 General specifications for Chinese national standard sockets
EN 50075 Special requirements for European standard household plugs and sockets
Technical Parameters
| No | Item | Parameter |
| 1 | Power Supply | AC380, 50Hz. |
| 2 | Voltage V | Range 0 ~ 300V accuracy ±5% |
| 3 | Current A | Range 0 ~ 60A accuracy ±5% |
| 4 | Power KW | Range 0~10KW, accuracy ±0.5% |
| 5 | Power Factor | Range 0.3 to 0.98 accuracy ±0.5% |
| 6 | Load Selection | Resistive, Inductive and Capacitive load three in one, switchable |
| 7 | Capacitance Selection | 70uf, 140uf, 73uf optional |
| 8 | Output Mode | Each power, Interval power optional |
| 9 | Count/Preset | 0~999999 times, can be preset |
| 10 | Load power capacity | 2*20KVA |
| 11 | Output current limit | 60A, the load will be automatically cut off when over 63A |
| 12 | Output voltage limit | 300V, the load will be automatically cut off when over 320V |
| 13 | Atmospheric pressure | 80~106kpa |
| 14 | Ambient temperature | 5~40°C |
| 15 | Relative humidity | (20~90)%RH |
| 16 | Use environment | Requires no violent shaking, no vibration, no electromagnetic interference, no dust, no explosive, no corrosive gases, needs good heat dissipation place |
| 17 | Dimensions and weight |
L*W*H=1200*760*1830mm, 800kg |
Picture for reference:
Define safety with expertise, verify quality with load
HC9915A power load cabinet - let every socket stand the rigorous test of the global market!
Get in Touch